• 제목/요약/키워드: inverter function

검색결과 330건 처리시간 0.024초

유럽형 전동차용 보조전원장치 개발 (Development of Static Inverter for European Electric Railway)

  • 김상균;김기훈;이현석;이경복;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.634-639
    • /
    • 2003
  • The static inverter is mainly used to provide with the electric power of various loads in the train. In the recent european projects, the specification of static inverter become harder, and many additional service function is expected. It takes long time and high cost to develope a static inverter with these high performances and additional function. But, these are became general demands for static inverter in the many projects from now on. The APSE(Auxiliary Power Supply Equipment) is a static inverter of high performance to satisfy the severe specification and various service function following these tendency for Athens project In this paper, the specification of APSE and various service functions are introduced to look about current tendencies of static inverter.

  • PDF

주파수 제어형 공진 인버터의 전달함수 (Transfer function of the Frequency-Controlled Resonant Inverter)

  • 안찬권;윤태성;이주형;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.393-396
    • /
    • 2004
  • This paper proposed a transfer function of a frequency-controlled resonant inverter for output power control. The inverter is modeled as an equivalent circuit by using Phasor transformation. A transfer function is derived from the equivalent circuit which contains cross-coupled nonlinear parts. By simulation of the circuit, the transfer function can be approximated as a linear first-order function. The proposed transfer function is verified through comparison of experimental and simulation results.

  • PDF

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

다기능 인버터의 손실저감을 위한 Buck-Type 충전기법 (Buck-Type Charging Method for Loss Reduction of Multi-Function Inverter)

  • 김동희;우동균;이병국
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1523-1528
    • /
    • 2011
  • This paper proposes buck-type charging method using motor inductance, 3-phase inverter and bi-directional converter without an additional charger in plug-in hybrid electric vehicles. The proposed system has advantages over the conventional system such as high charging efficiency, high power factor, and low total harmonic distortion. The validity of each methods are verified by theoretical analysis and simulation.

A Novel Multi-Function PV Micro-Inverter with an Optimized Harmonic Compensation Strategy

  • Zhu, Guofeng;Mu, Longhua;Yan, Junhua
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2284-2293
    • /
    • 2016
  • With the rapid development of clean energy, photovoltaic (PV) generation has been utilized in the harmonic compensation of power systems. This paper presents a novel multi-function PV micro-inverter with three stages (pseudo-two-stage). It can inject active power and compensate harmonic currents in the power grid at the same time. In order to keep the micro-inverter working under the maximum allowable output power, an optimized capacity limitation strategy is presented. Moreover, the harmonic compensation can be adjusted according to the customized requirements of power quality. Additionally, a phase shedding strategy in the DC/DC stage is introduced to improve the efficiency of parallel Boost converters in a wide range. Compared with existing capacity limitation methods, the proposed strategy shows better performance and energy efficiency. Simulations and experiments verify the feasibility of the micro-inverter and the effectiveness of the strategy.

UPS 기능을 갖는 A/C Blower용 Inverter 시스템 개발 (Development of the Inverter System with UPS Function for the Air-Conditioning Blower)

  • 임승범;이윤하;지준근;목형수;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.345-346
    • /
    • 2010
  • The HVAC(Heating Ventilation and Air Conditioning) system is only controlled by turn on/turn off operations against to AC 380V input. Therefore, the efficiency of the system is reduced and noise occurs. Also, the blower is shut down at the AC power failure. In this paper, the inverter system with UPS function for the A/C(Air Conditioning) blower is proposed. Proposed inverter system which is powered from the AC and DC voltage can control speed, operation mode, and soft-start time using CAN communication. In case of the CAN communication failure, RS-232 communication could be used to control the hardware directly by the engineer that can solve existing problems. To verify the validity of proposed inverter system, simulations and experiments are carried out.

  • PDF

A Novel Cost-Effective Two-Level Inverter with Combined Use of Thyristors and IGBTs

  • Chen, Dezhi;Zhao, Wenliang;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.152-159
    • /
    • 2018
  • In this paper, a novel topology of two-level voltage-type inverter is proposed. The proposed inverter has three bridge arms while each bridge is made up of two thyristors, one IGBT and four diodes. Thyristors complete the phase positioning of the inverter, IGBT completes the modulation of different modulation modes such as SPWM, SVPWM, and SHPWM, and the diodes complete the commutation of the bridge arms. Compared to the traditional voltage-type inverter with six IGBTs, the proposed voltage-type inverter using three IGBTs can achieve the same function with highly reduced cost. The principle of the proposed two-level inverter is explained in detail. The simulation and experiment results demonstrate the performance and effectiveness of the proposed inverter-type inverter.

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

고유전율 게이트 산화막을 가진 적층형 3차원 인버터의 일함수 변화 영향에 의한 문턱전압 변화 조사 (Investigation of threshold voltage change due to the influence of work-function variation of monolithic 3D Inverter with High-K Gate Oxide)

  • 이근재;유윤섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.118-120
    • /
    • 2022
  • 본 논문은 M3D(Monolithic 3-Dimension) Inverter의 소자 구조에서 메탈 게이트의 WFV(Work-function Variation)의 영향에 따른 임계전압의 변화에 대하여 조사했다. 또한 PMOS 위에 NMOS가 적층된 인버터의 전기적 상호작용에 따른 임계전압의 변화를 조사하기 위해 PMOS에 0과 1 V의 전압을 인가하여 전기적 상호작용을 조사하였다. 사용된 메탈 게이트의 평균 일함수에 대한 임계전압의 변화량은 0.1684 V로 측정되었고, 표준편차는 0.00079 V가 조사 되었다.

  • PDF

외부부하가 $I^2L-Inverter$의 기능에 미치는 영향 (The Influence of the External Loads on the $I^2L-Inverter$ Function)

  • 이규영;황호정
    • 대한전자공학회논문지
    • /
    • 제22권2호
    • /
    • pp.75-81
    • /
    • 1985
  • 저전류 범위에서 l2L은 연결되는 소자의 input capacitance, resistance 및 그 소자동작에 필요한 전류들에 의해 출력단의 신호가 손상을 입게 되어 logic기능이 방해를 받게 되며 그로 인한 회로의 불확실성이 증가될 수 있다. 본 논문은 이와같은 외부부하와 연결된 I2L-inverter의 기능에 관한 해석을 다루고 rise time과 fall time의 변화에 관한 simulation 및 실험을 통한 측정결과를 비교 분석하였다.

  • PDF