• Title/Summary/Keyword: interval parameters

Search Result 883, Processing Time 0.039 seconds

Robust regulator design for an interval plant (구간 플랜트에 대한 견실한 레귤레이타 설계)

  • 김기두;김석중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.173-178
    • /
    • 1993
  • In this paper, we present an algorithmic technique for determining a feedback compensator which will stabilize the interval dynamic system, specifically, the robust regulator design for interval plants. The approach taken here is to allow the system parameters to live within prescribed intervals then design a dynamic feedback compensator which guarantees closed-loop system stable. The main contribution of this paper is the idea of introducing a "simplified Kharitonov's result" for low order polynomials to search for suitable compensator parameters in the compensator parameter space to make the uncertain syste robust. We also design the robust regulator which will D-stabilize (have the closed-loop poles in the left sector only) the dynamic interval system while having good performance. The nuerical examples are given to show the substantially improved robustness which results from our approach. approach.

  • PDF

Robust Regulator Design for an Interval Plant (구경 플랜트에 대한 강건한 레귤레이터의 설계)

  • 김기두;김석중;조한유
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.64-73
    • /
    • 1994
  • In this paper we present an algorithmic technique for determining a feedback compensator which will stabilize the interval dynamic system specifically the robust regulator design for interval plants. The approach taken here is to allow the system parameters to live within prescribed intervals then design a dynamic feedback compensator which guarantees closed-loop system stable. The main contribution of this paper is the idea of introducting a "simplified Kharitonov`s results" for low order polynomials to search for suitable compensator parameters in the compensator parammeter space to make the uncertain system robust. We also design the robust regulator which will $D_{\phi}$ -stabilize (have the closed-loop poles in the left sector only) the dynamic interval system while having good performance. the numerical examples are given to show the substantially improved robustness which results from our approach.

  • PDF

Effect of Input Data Video Interval and Input Data Image Similarity on Learning Accuracy in 3D-CNN

  • Kim, Heeil;Chung, Yeongjee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.208-217
    • /
    • 2021
  • 3D-CNN is one of the deep learning techniques for learning time series data. However, these three-dimensional learning can generate many parameters, requiring high performance or having a significant impact on learning speed. We will use these 3D-CNNs to learn hand gesture and find the parameters that showed the highest accuracy, and then analyze how the accuracy of 3D-CNN varies through input data changes without any structural changes in 3D-CNN. First, choose the interval of the input data. This adjusts the ratio of the stop interval to the gesture interval. Secondly, the corresponding interframe mean value is obtained by measuring and normalizing the similarity of images through interclass 2D cross correlation analysis. This experiment demonstrates that changes in input data affect learning accuracy without structural changes in 3D-CNN. In this paper, we proposed two methods for changing input data. Experimental results show that input data can affect the accuracy of the model.

Ginsenoside-Re ameliorates ischemia and reperfusion injury in the heart: a hemodynamics approach

  • Lim, Kyu Hee;Lim, Dae-Jun;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.37 no.3
    • /
    • pp.283-292
    • /
    • 2013
  • Ginsenosides are divided into two groups based on the types of the panaxadiol group (e.g., ginsenoside-Rb1 and -Rc) and the panaxatriol group (e.g., ginsenoside-Rg1 and -Re). Among them, ginsenoside-Re (G-Re) is one of the compounds with the highest content in Panax ginseng and is responsible for pharmacological effects. However, it is not yet well reported if G-Re increases the hemodynamics functions on ischemia (30 min)/reperfusion (120 min) (I/R) induction. Therefore, in the present study, we investigated whether treatment of G-Re facilitated the recovery of hemodynamic parameters (heart rate, perfusion pressure, aortic flow, coronary flow, and cardiac output) and left ventricular developed pressure (${\pm}dp/dt_{max}$). This research is designed to study the effects of G-Re by studying electrocardiographic changes such as QRS interval, QT interval and R-R interval, and inflammatory marker such as tissue necrosis factor-${\alpha}$ (TNF-${\alpha}$) in heart tissue in I/R-induced heart. From the results, I/R induction gave a significant increase in QRS interval, QT interval and R-R interval, but showed decrease in all hemodynamic parameters. I/R induction resulted in increased TNF-${\alpha}$ level. Treatment of G-Re at 30 and $100{\mu}M$ doses before I/R induction significantly prevented the decrease in hemodynamic parameters, ameliorated the electrocardiographic abnormality, and inhibited TNF-${\alpha}$ level. In this study, G-Re at $100{\mu}M$ dose exerted more beneficial effects on cardiac function and preservation of myocardium in I/R injury than $30{\mu}M$. Collectively, these results indicate that G-Re has distinct cardioprotectective effects in I/R induced rat heart.

Sequential Estimation of variable width confidence interval for the mean

  • Kim, Sung Lai
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.14 no.2
    • /
    • pp.47-54
    • /
    • 2001
  • Let {Xn, n = 1,2,${\cdots}$} be i.i.d. random variables with the only unknown parameters mean ${\mu}$ and variance a ${\sigma}^2$. We consider a sequential confidence interval C1 for the mean with coverage probability 1-${\alpha}$ and expected length of confidence interval $E_{\theta}$(Length of CI)/${\mid}{\mu}{\mid}{\leq}k$ (k : constant) and give some asymptotic properties of the stopping time in various limiting situations.

  • PDF

Voiced, Unvoiced, and Silence Classification of human speech signals by enphasis characteristics of spectrum (Spectrum 강조특성을 이용한 음성신호에서 Voicd - Unvoiced - Silence 분류)

  • 배명수;안수길
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 1985
  • In this paper, we describe a new algorithm for deciding whether a given segment of a speech signal is classified as voiced speech, unvoiced speech, or silence, based on parameters made on the signal. The measured parameters for the voiced-unvoiced classfication are the areas of each Zero crossing interval, which is given by multiplication of the magnitude by the inverse zero corssing rate of speech signals. The employed parameter for the unvoiced-silence classification, also, are each of positive area summation during four milisecond interval for the high frequency emphasized speech signals.

  • PDF

EVALUATION OF KINETIC PARAMETERS IN ENZYMIC NON-LINEAR PROGRESS REACTIONS

  • Lee Hyun-Jae;Kim Soo Ja
    • Journal of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.11-14
    • /
    • 1971
  • A modified form of the integrated Michaelis-Menten equation would provide a useful means of evaluating enzyme kinetic parameters in nonlinear progress reaction with time. A slight modification of the Lineweaver-Burk form (and other variants) using for the velocity, the change in substrate concentration divided by time ($\={v}$), and for the velocity, the change in substrate for the time interval ($\={S}$), allows this linear reciprocal form to be used with negligible error even when as much as half of the substrate is utilized during the time interval.

  • PDF

A Reduction Algorithm of Computational Amount using Adjustment the Not Uniform Interval and Distribution Characteristic of LSP (불균등 간격조절과 선형 스펙트럼 쌍 분포특성을 이용한 계산량 단축 알고리즘)

  • Ju, Sang-Gyu
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.261-264
    • /
    • 2010
  • Fast algorithm is proposed by using mel scale and the distribution characteristic of LSP parameters, and is to reduce the computational amount. Computational amount means the calculating times of transformation from LPC coefficients to LSP parameters. Among conventional methods, the real root method is considerably simpler than other, but neverthless, it still suffer from its indeterministic computational time. Because the root searching is processed sequentially in frequency region. In this paper, the searching interval is arranged by using mel scale but not it is uniform and searching order is arranged by the distribution characteristic of LSP parameters that is most LSP papameters are occured in specific frequency region. In experimental results, computational amount of the proposed algorithm is reduced about 48.95% in average, but the transformed LSP parameters of the proposed method were the same as those of real root method.

  • PDF

The Effects of PRF and Slot Interval on the PPM-Based Ultra Wide-Band Systems (PPM-기반의 UWB 시스템에 대한 PRF와 슬롯 시간의 영향)

  • 김성준;임성빈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12C
    • /
    • pp.1192-1199
    • /
    • 2003
  • In this paper, we investigate the effect of pulse repetition frequency (PRF) and slot interval on the throughput performance of the ultra wide band (UWB) wireless communication system in multi-path channels, and based on these observations, a data throughput control using PRF and slot interval is proposed for maximizing the effective throughput. Recently, due to many desirable features of the UWB system, it has drawn much attention especially for short-range high-speed data transmission. The UWB system has two parameters to determine its data throughput; pulse repetition frequency and slot interval. In the multi-path channel with additive white Gaussian noise, the UWB system suffers from the inter-pulse interference (IPI) and noise, which result in degradation of system performance. The UWB system can vary the two parameters to maintain and/or improve the system performance. In this paper, we demonstrate the effects of the two parameters on the data throughput of the UWB system in various multi-path indoor channels through computer simulation, and show that the variable data rate approach designed based on the observations is superior to the fixed data rate one in terms of effective throughput performance.

Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter (레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발)

  • 배기윤;이정인
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.