• Title/Summary/Keyword: interfacial energy

Search Result 625, Processing Time 0.025 seconds

Effects of Dielectric Curing Temperature and T/H Treatment on the Interfacial Adhesion Energies of Ti/PBO for Cu RDL Applications of FOWLP (FOWLP Cu 재배선 적용을 위한 절연층 경화 온도 및 고온/고습 처리가 Ti/PBO 계면접착에너지에 미치는 영향)

  • Kirak Son;Gahui Kim;Young-Bae Park
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.2
    • /
    • pp.52-59
    • /
    • 2023
  • The effects of dielectric curing temperature and temperature/humidity treatment conditions on the interfacial adhesion energies between Ti diffusion barrier/polybenzoxazole (PBO) dielectric layers were systematically investigated for Cu redistribution layer applications of fan-out wafer level package. The initial interfacial adhesion energies were 16.63, 25.95, 16.58 J/m2 for PBO curing temperatures at 175, 200, and 225 ℃, respectively. X-ray photoelectron spectroscopy analysis showed that there exists a good correlation between the interfacial adhesion energy and the C-O peak area fractions at PBO delaminated surfaces. And the interfacial adhesion energies of samples cured at 200 ℃ decreased to 3.99 J/m2 after 500 h at 85 ℃/85 % relative humidity, possibly due to the weak boundary layer formation inside PBO near Ti/PBO interface.

Relations Between Impact Damage and Ply Angle Under Same Impact Energy Condition (同一한 衝擊에너지 條件下의 CFRP 斜交積層板의 衝擊損傷과 配向角의 關係)

  • ;笠野英秋
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1824-1832
    • /
    • 1992
  • This study investigated the compressive Young's modulus and the impactinduced damage of CFRP angle-ply laminate under same impact energy condition. The specimens of angle-ply laminate composites [0.deg.$_{6}$/ .theta..deg.$_{10}$/ 0.deg.$_{6}$] with .theta..deg. =30.deg., 45.deg., 60.deg. and 90.deg. were employed, and damaged by steel balls of diameter of 5mm and 10mm propelled by air gun type impact testing machine. The impact damaged zones were observed through a scanning acoustic microscope(SAM), and their cross-sections were observed through a scanning electron microscope(SEM). The compressive Young's moduli before and after impact were measured, and compared with the theoretical values calculated. The results obtained were as follows: (1) The damage areas on the interfacial boundaries showed more severe change on the back side interface than on the impact side interface with increasing ply-angle. (2) The damage areas on the interfacial boundaries became larger with increasing impact velocity or ply-angle. (3) The impact damaged zone showed the delamination on the interfacial boundaries and transverse cracks inside laminas. (4) The impact damaged zone was affected by the impactor size and speed or ply-angle under same impact energy condition. (5) Compressive Young's moduli before and after impact were lower than theoretical value, but showed a similar change according to ply-angle. (6) Compressive Young's moduli after impact were higher than those before impact, but there was no remarkable change in apparent compressive modulus after impact.t.act.

Fracture Behavior of Glass/Resin/Glass Sandwich Structures with Different Resin Thicknesses (서로 다른 레진 두께를 갖는 유리/레진/유리샌드위치 구조의 파괴거동)

  • Park, Jae-Hong;Lee, Eu-Gene;Kim, Tae-Woo;Yim, Hong-Jae;Lee, Kee-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1849-1856
    • /
    • 2010
  • Glass/resin/glass laminate structures are used in the automobile, biological, and display industries. The sandwich structures are used in the micro/nanoimprint process to fabricate a variety of functional components and devices in fields such as display, optics, MEMS, and bioindustry. In the process, micrometer- or nanometer-scale patterns are transferred onto the substrate using UV curing resins. The demodling process has an important impact on productivity. In this study, we investigated the fracture behavior of glass/resin/glass laminates fabricated via UV curing. We performed measurements of the adhesion force and the interfacial energy between the mold and resin materials using the four-point flexural test. The bending-test measurements and the load-displacement curves of the laminates indicate that the fracture behavior is influenced by the interfacial energy between the mold and resin and the resin thickness.

Effect of Atmospheric Plasma Treatment of Carbon Fibers on Crack Resistance of Carbon Fibers-reinforced Epoxy Composites

  • Park, Soo-Jin;Oh, Jin-Seok;Rhee, Kyong-Yop
    • Carbon letters
    • /
    • v.6 no.2
    • /
    • pp.106-110
    • /
    • 2005
  • In this work, the effects of atmospheric oxygen plasma treatment of carbon fibers on mechanical interfacial properties of carbon fibers-reinforced epoxy matrix composites was studied. The surface properties of the carbon fibers were determined by acid/base values, Fourier-transform infrared spectrometer (FT-IR), and X-ray photoelectron spectroscopy (XPS) analyses. Also, the crack resistance properties of the composites were investigated in critical stress intensity factor ($K_{IC}$), and critical strain energy release rate mode II ($G_{IIC}$) measurements. As experimental results, FT-IR of the carbon fibers showed that the carboxyl/ester groups (C=O) at 1632 $cm^{-1}$ and hydroxyl group (O-H) at 3450 $cm^{-1}$ were observed for the plasma treated carbon fibers, and the treated carbon fibers had the higher O-H peak intensity than that of the untreated ones. The XPS results also indicated that the $O_{1S}/C_{1S}$ ratio of the carbon fiber surfaces treated by the oxygen plasma led to development of oxygen-containing functional groups. The mechanical interfacial properties of the composites, including $K_{IC}$ (critical stress intensity factor) and $G_{IIC}$ (critical strain energy release rate mode II), were also improved for the oxygen plasma-treated carbon fibersreinforced composites. These results could be explained that the oxygen plasma treatment played an important role to increase interfacial adhesions between carbon fibers and epoxy matrix resins in our composite system.

  • PDF

Filler-Elastomer Interactions. 10. Ozone Treatment on Interfacial Adhesion of Carbon Blacks/NBR Compounds (충전재-탄성체 상호작용. 10. 카본블랙/NBR 복합재료의 계면 접착에 미치는 오존처리의 영향)

  • Cho, Ki-Sook;Zaborski, M.;Slusarski, L.;Park, Soo-Jin
    • Elastomers and Composites
    • /
    • v.38 no.2
    • /
    • pp.139-146
    • /
    • 2003
  • In this work, the influence of ozone treatment on surface properties of carbon black is investigated in terms of X-ray photoelectron spectroscopy (XPS) and contact angles. And their mechanical interfacial properties of the carbon black/acrylonitrile butadiene rubber (NBR) compounds are studied by the crosslink density and composite tearing energy ($G_{IIIC}$). As a result, it is found that the increasing of the ozone concentration leads to an increase of the introduction rate of oxygen-containing functional groups onto carbon black surfaces and to an increase of the surface free energy, resulting in improving both crosslink density and tearing energy ($G_{IIIC}$) of the compounds. The results can be explained by the fact that the oxygen-containing functional groups of carbon black surfaces make an increase of the degree of adhesion at interfaces between carbon blacks and rubber matrix.

Filler-Elastomer Interactions. 6. Influence of Oxygen Plasma Treatment on Surface Properties of Carbon Blacks (충전재-탄성체 상호작용. 6. 산소 플라즈마 처리가 카본블랙표면특성 미치는 영향)

  • Cho, Ki-Sook;Zoborski, M.;Slusarski, L.;Park, Soo-Jin
    • Elastomers and Composites
    • /
    • v.37 no.2
    • /
    • pp.99-106
    • /
    • 2002
  • In this work, the surface properties and mechanical interfacial properties of the carbon blacks treated by oxygen plasma were investigated. The surface properties of carbon black by oxidation process of oxygen plasma were studied in acid-base surface value, zeta potential, and X-ray photoelectron spectroscopy (XPS). And their mechanical interfacial properties of the carbon black/rubber composites were evaluated by the composite tearing energy ($G_{III}c$). As a result, it was found that the introduction rate of oxygen-containing polar functional groups, such as carboxyl, hydroxyl, lactone, and carbonyl groups, onto the carbon black surfaces was increased by increasing the plasma treatment time. It revealed that the polar rubber, such as acrylonitrile butadiene rubber (NBR), showed relatively a high degree of interaction with oxygen-containing functional groups of the carbon black surfaces, resulting in improving the tearing energy ($G_{III}c$) of the carbon black/acrlyonitrile butadiene rubber composites.

Interfacial Electrical Studios on Adhesion of Hematite Particles to Polyester Fabric and their Removal from the Fabric(Part 2) (Polyester 직물에의 Hematite 입자의 부착과 제거에 관한 계면 전기적고찰 (제2보))

  • 강인숙;김성련
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.5
    • /
    • pp.765-773
    • /
    • 1995
  • Effect of interfacial electrical conditions such as, the f potential of PET fiber and u-Fe203 particles, the stability parameter and potential energy of interaction on adhesion of a-Fe903 particles to PET fabric and their removal from the fabric, were investigated as functions of pH, electrolyte and ionic strength. The stability parameter, potential energy of interaction between a-Fe2O3 particles and PET fabric were calculated by using the heterocoagulation theory for a sphere-plate model The adhesion of a-Fe2O3 particles to PET fabric and their removal from PET fabric were carried out by using water bath shaker and Terg-O-Tometer under various solution conditions. The adhesion of a-Fe2O3 particles to the PET fabric and the removal of a-Fe2O3 particles from the PET fabric were biphasic and were maximum and minimum at pH 7~8, respectively. With high pH and polyanion electrolytes in solution, the adhesion of a-Fe2O3 particles to the PET fabric was low but effects of electrolytes on the removal of a-Fe2O3 particles from the PET fabric was small. The adhesion of a-Fe2O3 particles to the PET fabric and the removal of a-Fe2O3 Particles from the PET fabric were biphasic, and were lowest and highest at the ionic strength 1$\times$10-3, respectively. The adhesion of a-Fe2O3 particles to PET fabric was well related with the interfacial electrical conditions; it was negatively correlated with the f potentials of a-Fe2O3 Particles of its absolute value, the stability parameter and the maximum of total potential energy, while, the adhesion was not related with the t potentials of PET fiber itself. Therefore, the primary factor determining the adhesion of a-Fe203 particles to PET fabric may be the stability of dispersed particles caused by the electrical repulsion of particles. The removal of a-Fe203 particles from PET fabric was not related to such interfacial electrical conditions as the t potentials of PET fiber, the stability parameter and the maximum of total potential energy but removal was related to t potential of a-Fe203 particles.

  • PDF

Characterization and observation of Cu-Cu Thermo-Compression Bonding using 4-point bending test system (4-point bending test system을 이용한 Cu-Cu 열 압착 접합 특성 평가)

  • Kim, Jae-Won;Kim, Kwang-Seop;Lee, Hak-Joo;Kim, Hee-Yeon;Park, Young-Bae;Hyun, Seung-Min
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.11-18
    • /
    • 2011
  • The quantitative interfacial adhesion energy of the Cu-Cu direct bonding layers was evaluated in terms of the bonding temperature and Ar+$H_2$ plasma treatment on Cu surface by using a 4-point bending test. The interfacial adhesion energy and bonding quality depend on increased bonding temperature and post-annealing temperature. With increasing bonding temperature from $250^{\circ}C$ to $350^{\circ}C$, the interfacial adhesion energy increase from $1.38{\pm}1.06$ $J/m^2$ to $10.36{\pm}1.01$ $J/m^2$. The Ar+$H_2$ plasma treatment on Cu surface drastically increase the interfacial adhesion energy form $1.38{\pm}1.06$ $J/m^2$ to $6.59{\pm}0.03$ $J/m^2$. The plasma pre-treatment successfully reduces processing temperature of Cu to Cu direct bonding.

Effect of $Ar^+$ RF Plasma Treatment Conditions on Interfacial Adhesion Energy Between Cu and ALD $Al_2O_3$ Thin Films for Embedded PCB Applications ($Ar^+$ RF 플라즈마 처리조건이 임베디드 PCB내 전극 Cu박막과 ALD $Al_2O_3$ 박막 사이의 계면파괴에너지에 미치는 영향)

  • Park, Sung-Cheol;Lee, Jang-Hee;Lee, Jung-Won;Lee, In-Hyung;Lee, Seung-Eun;Song, Byoung-Ikg;Chung, Yul-Kyo;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • Interfacial fracture energy(${\Gamma}$) between $Al_2O_3$ thin film deposited by Atomic Layer Deposition(ALD) and sputter deposited Cu electrode for embedded PCB applications is measured from a $90^{\circ}$ peel test. While the interfacial fracture energy of $Cu/Al_2O_3$ is very poor, Cr adhesion layer increases the interfacial fracture energy to $39.8{\pm}3.2g/mm\;for\;Ar^+$ RF plasma power density of $0.123W/cm^2$, which seems to come from the enhancement of the mechanical interlocking and Cr-O chemical bonding effects.

  • PDF

A Study on Surface Properties of Mechanical Interfacial Behavior of DGEBA/PMR-15 Blends (DGEBA/PMR-15 블렌드계의 표면특성 변화가 기계적 계면특성에 미지는 영향)

  • Park, Soo-Jin;Lee, Hwa-Young;Han, Mijeong;Hong, Sung-Kwon
    • Journal of Adhesion and Interface
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • In this work, the effect of PMR-15 content on the variation of surface free energy of the DGEBA/PMR-15 blend system was investigated in terms of contact angles and mechanical interfacial tests. Based on FT-IR result of the blend system. C=O (1,772, $1,778cm^{-1}$) and C-N ($1,372cm^{-1}$) peaks appeared with imidization of PMR-15 and -OH ($3,500cm^{-1}$) peak showed broadly at 10 phr of PMR-15 by ring-opening of epoxy. Contact angle measurements were performed by using deionized water and diiodomethane as testing liquids. As a result, the surface free energy of the blends gave a maximum value at 10 phr of PMR-15, due to the significant increasing of specific component. The mechanical interfacial properties measured from the critical stress intensity factor ($K_{IC}$) and the critical strain energy release rate ($G_{IC}$) showed a similar behavior with the results of surface energetics. This behavior was probably attributed to The improving of the interfacial adhesion between intermolecules, resulting from increasing the hydrogen bondings of the blends.

  • PDF