Thermal Insulation Property due to Internal Air-layer Content of Warm Multi Layer Materials by using Numerical Analysis (수치해석을 이용한 다겹보온자재의 내부공기층 함유에 따른 보온 특성)

  • Chung, Sung-Won
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.97-103
    • /
    • 2012
  • This study investigates thermal insulation properties of multi layer materials depending on thickness of air layers. Numerical analysis on the heat flow of different insulating materials was conducted to identify whether their temperature distributions demonstrate the reduced rate of heat transfer conclusively or not. Analytical model is divided into two categories. One is to distinguish temperature distribution of the air-layer materials from the non-air layer ones. The other is to compare the efficacy between eight-layered insulating materials with no air-layer contained and three-layered insulating materials which include an air-layer definitely. In the latter case, the identical thickness is assigned to each material. The effect of thermal insulation by including an air-layer is verified in the first analytical model. The result of the second model shows that the insulation of the eight-layered materials is coterminous at the three-layered ones with an air-layer and the thermal insulation of the two materials is imperceptible. The benefits of cost and energy saving are anticipated if air-layers are efficiently incorporated in multi layer insulating materials in a greenhouse.

Improvement on Property of Insulation in PT of Epoxy Mold Type (에폭시 몰드형 PT의 절연특성 개선)

  • Song, Jae-Joo;Kim, Sung-Hong;Choi, Myeong-Ho;Lee, Jae;Lim, Sung-Hun;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.67-71
    • /
    • 2001
  • PT of epoxy mold type have tendency to occur dielectric breakdown in high voltage system. These are using for measurement of voltage or protection of system and application voltage is 25.8kV. Therefore, for improving a lots of problems like as partial discharge, we had analyze on the destroyed Epoxy molded type PT and processing of production. As a results, we concluded that the reason of dielectric breakdown was defect of processing and degradation of insulation by electrical stress. In this work, We presented a method of solution in processing of production. which is reduction of the PO which was occurred at the insulation material. so we must many try to remove faults, these problems are mainly to winding methods of 1st coil. the other side, Reformation of 1st coil improved property of PD and we could prove it with experiments.

  • PDF

Analysis of Characteristics of Slurry and Thermal Insulation Materials Using Hauyne Cement

  • Kim, Tae Yeon;Jo, Ki Sic;Chu, Yong Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.5
    • /
    • pp.468-473
    • /
    • 2019
  • This study focused on manufacturing an inorganic insulation material set with various amounts of calcium-sulfoaluminate (CSA) (hauyne) content for enhancing both workability (demolding, handling) and the high thermal insulating property. To carry out the experiment, the amounts of CSA utilized were 5%, 10%, 15%, and 20%, with anhydrous gypsum added in equal proportion to produce a stable formation. As the content of CSA increased, a sinking phenomenon occurred because of the hydration reaction from the slurry, so it was difficult to utilize a retarder normally used in the cement manufacturing process. However, an RCOOM surfactant was able to solve the local clumping problem from cement and CSA and obtain a rapid retarding effect, so it was included in this process at 0.3%. Furthermore, the cement fineness was not 7000 ㎠/g but rather 3300 ~ 4000 ㎠/g to prevent a rapid temperature increase in the slurry. The specific gravity of the sample manufactured with 20% CSA was approximately 0.11 g/㎤, and its thermal conductivity was 0.041 W/m·K, providing an excellent insulating property.

Evaluation of Thermal Insulation and Hypothermia for Development of Life Raft (해상 구명정의 단열성능평가 및 저체온증 예측 수치해석 연구)

  • Hwang, Se-Yun;Jang, Ho-Sang;Kim, Kyung-Woo;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.485-491
    • /
    • 2015
  • The technology review about risk of hypothermia of victim according to heat transfer characteristic of life raft and sea state can use accident correspondence of standing and sinking of ship. This study studied heat transfer characteristics required for the design of life raft and thermal insulation property analysis and evaluation methods. In addition, it is study for comprehend the risk of hypothermia and suggest analysis result that is experiment of thermal insulation property and body temperature property for decide of prediction the body temperature decline Thermal Analysis apply the finite element analysis method is comprehended the property of heat conductivity, convective effect of sea water and properties changes according to property of insulation material. it measure the heat flux with attach temperature sensor on body in order to comprehend the variation of body temperature with boarding a life raft experiment on a human body. This study validate results by comparing variation of temperature measured from experiment on a body with variation of temperature from finite element analysis model. Also, the criteria of hypothermia was discussed through result of finite element analysis.

Comfort Properties of Silk#x00B7;Rayon-Cellulose Fiber Union Fabrics (견·인견과 셀룰로오스섬유 교직물의 쾌적성능 평가)

  • Bae, Young Hee;Yun, Chang Sang;Jeong, Woon Seon
    • The Korean Journal of Community Living Science
    • /
    • v.27 no.4
    • /
    • pp.795-801
    • /
    • 2016
  • This study was conducted to suggest the best union fabric to combine with cellulose fiber for summer and in-between seasons. Four types of union fabric, viz. silk/flax, silk/cotton, rayon/flax and rayon/cotton, were used as sample fabrics after weaving them in a local textile factory. The air permeability, moisture regain, water absorption, water vapor permeability and thermal insulation of the samples were tested. The results are as follows. The rayon/flax union fabric is the most suitable for summer clothes due to its having the best comfort property of air and water vapor permeability, and moisture and water absorption. For in-between seasons, it is recommended to use the silk/cotton union fabric because of its good thermal insulation properties.

A Study on the Curing Property of the Epoxy Resin (에폭시수지의 경화특성에 관한 연구)

  • Lee, Jin;Lee, Eun-Hak;Song, Hee-Su;Kim, Tae-Seoung
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.246-248
    • /
    • 1988
  • The electrical insulation characteristics of the Epoxy resin is generally depended upon the cross-Link. Therefore, when the Epoxy is cured the full cross-Link must be gotten to obtain the best electrical insulation property. This paper alms at examining the cure condition to get the best cross-link. The Epoxy used in this experiment is DGEBA, the curing materiel is MNA, and the accellator is tertiary amine. In this study, the best curing condition of cross-link is suggested by analysing the each Epoxy resin which is differenty cured according Lo the variable temperatures and curing times.

  • PDF

Dependencies of Dielectric Properties on Temperature and Frequency in PET films with interfaces (계면을 갖는 PET 필름의 유전특성의 온도 및 주파수 의존성)

  • Lee, Chang-Hoon;Lee, Jong-Bok;Lee, Dong-Young;Kang, Moo-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.938-940
    • /
    • 1998
  • In order to improve insulating character and ability of insulating system of power apparatus, the interfacial and complex structure is widely used. However, the interface or complex structure of insulation materials is reported as a weak point which causes breakdown. As the interface of insulation system degrades its electrical property and eventually causes a failure, the datailed phenomenon analysis is reported. The object of this paper is to evaluate dielectric property of PET film with the interface. The $tan{\delta}$ increased with the existence of semiconducting layer and showed prominent decrease as a function of temperature. Also, the $tan{\delta}$ showed prominent increase as a function of frequency. The dielectric properties of interfacial were affected by the interface characteristics.

  • PDF

Properties Electric of AIN Thin Film on the Si and GaAs Substrate (Si와 GaAs기판 위에 AIN 박막의 전기적 특성)

  • Park, Jung-Cheul;Chu, Soon-Nam;Kwon, Jung-Youl;Lee, Heon-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • To study the effects of $H_2$ gas on AIN insulation thin film, we prepared AIN thin film on Si and GaAs substrate by means of reactive sputtering method using $H_2$ gas as an additives, With treatment conditions of $H_2$ gas AIN thin film shows variable electrical properties such as its crystallization and hysterisis affected to electrical property, As a results, AIN thin film fabricated on Si substrate post-treated with $H_2$ gas for 20 minutes shows much better an insulation property than that of pre-treated, And AIN film treated with $H_2$ gas comparing to non-treated AIN film shows a flat band voltage decreasment. But In GaAs substrate $H_2$ gas does not effect on the flat band voltage.

Evaluation of the Property of adiabatic Insulation for TTX Train with Sandwich Composite bodyshell (샌드위치 복합소재가 적용된 틸팅 차량의 단열 특성 평가 연구)

  • Lee Sang-Jin;Oh Kyung-Won;Jeong Jong-Cheol;Cho Se-Hyun;Seo Soung-il
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.251-256
    • /
    • 2005
  • This study was performed the heat transportation ratio of three types of the following sandwich panel by KS F 2278(2003) ; Type ${\sharp}1$ : Carbon/epoxy Aluminum Honeycomb and Balsa Core Sandwich Panel(Thickness : 37mm), Type ${\sharp}2$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 57mm), and Type ${\sharp}3$ : Carbon/epoxy Aluminum Honeycomb Core Sandwich Panel(Thickness : 37mm). Also was performed the heat transportation of next three types of the following sandwich panel by KS F2277(2002) ; Type ${\sharp}4$ and ${\sharp}5$ : 27mm, and 35mm thick-Aluminum Honeycomb Sandwich Panels, and Type ${\sharp}6$ : 27mm thick-Foaming Aluminum Sandwich Panel. It is the larger area between the skin and core, the heat transportation ratio is the higher, and when it is composed of the hybrid composite structure, good insulation property was shown.

  • PDF

The Temperature Characteristics of Epoxy Resin by Curing Time (에폭시 수지의 경화에 따른 온도 특성)

  • Lee, Jin;Lee, Eun-Hak;Lim, Young-Choel;Lee, Kye-Ho;Park, Jong-Kun;Kim, Tae-Seoung
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.771-773
    • /
    • 1988
  • The Mechanical strength and the electrical insulation properties of the Epoxy Resin vary with the formation of chemical reactions between Epoxy and curing agent. Therefore, to study their reactions is important for understanding the properties of the cured Epoxy. In this paper, to get the cured Epoxy having good electrical insulation property, it is studied the effects of the surrounding temperature during the cure process on the property of the cured Epoxy. In the experiment, Epoxy is cured with the surrounding temperature varied between -5[$^{\circ}C$] to 50[$^{\circ}C$]. As the results, it follows that the higher the temperature is, the faster the cross-link process is.

  • PDF