Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer (유입변압기 오일필터링에 따른 유전정접 변화사례 고찰)

  • Kong, Tae-Sik;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF

Ionization and Attachment Coefficients in Mixtures of $SF_6$ and $N_2$ ($SF_6-N_2$ 혼합기체(混合氣體)의 전리(電離) 및 부착계수(附着係數))

  • Kim, Sang-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.44-47
    • /
    • 2009
  • This paper describes the information for quantitative simulation of weakly ionized plasma. We must grasp the meaning of the plasma state condition to utilize engineering application and to understand materials of plasma state. $SF_6$ gas is widely used in industrial of insulation field. In this paper, $N_2$ is mixed to improve pure $SF_6$ gas characteristics. Electron transport coefficients in $SF_6-N_2$ mixture gases are simulated in range of E/N values from 70 to 400 [Td] at 300K and 1 Torr by using Boltzmann equation method. The results of this method. which are ionization coefficient, attachment coefficient, effective ionization coefficient, and critical E/N, can be important data to present characteristic of gas for insulation. Specially critical E/N is a data to evaluate insulation strength of a gas and is presented in this paper for various mixture ratios of $SF_6-N_2$ mixture gases.

Characteristic Comparison of Raw Materials Used for Power Cable Insulation (전력케이블 절연층용 원재료의 특성비교)

  • Oh, Woo-Jeong;Ko, Jung-Woo;Kim, Jong-Eun;Suh, Kwang-S.;Lee, Gun-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.302-304
    • /
    • 1997
  • Chemical structure and electrical properties such as water treeing and space charge accumulation of various raw materials(XLPE) used for power cable insulation were investigated. It was found that chemical structure was changed after crosslinking reaction and every materials have different amounts of DCP and antioxidant. Electrical properties were also changed after extraction using $CHCl_3$ and xylene. Water tree length was smaller with additives such as DCP and antioxidant and bigger with low molecular weight components of polyethylene than that of extracted samples. Heterocharge was changed into homocharge after extraction. This shows that additives and low molecular weight components of polyethylene cause the heterocharge.

  • PDF

A Preliminary Study to Develop the Construction Method for Working Exterior Simultaneously with Vertical Structural Work (공동주택용 외단열 적층시공 공법 개발을 위한 기초연구)

  • Cui, Jun-Long;Kim, Taehoon;Lim, Hyunsu;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.73-74
    • /
    • 2014
  • A construction method allowing exterior insulation working to be carried out simultaneously with vertical structural work through modification of the temporary vertical system form could be a breakthrough to invigorate exterior insulation construction in high-rise apartments. Therefore, the purpose of this study, as a preliminary study for developing such a method, was to derive significant engineering characteristics (E.C) using QFD which can reflect the users' need for E.C. Based on this result, a construction method will be developed in further research.

  • PDF

A Study on Corona Inception Voltage and Dielectric Characteristics of Thermally Aged Mineral and Vegetable Insulation Oil in Medium Voltage Power Transformer (식물유 및 광유를 사용한 배전변압기의 열열화에 따른 절연유의 코로나 개시전압 및 전기적 특성에 대한 연구)

  • Jeong, Jung-Il;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1745-1750
    • /
    • 2017
  • Starting from the distribution transformer, the insulation oil for the oil immersed power transformer is being used to convert the vegetable oil from the existing mineral oil. Vegetable oil is better in temperature characteristics and insulation performance, is not toxic, and has better biodegradable characteristic than that of mineral oil. In order to investigate the corona inception voltage and dieclectic charateristics of the two insulating oils, three oil immersed transformers using mineral oil and vegetable oil were made and thermal cyclic aged. In this paper, the changes in the corona discharge inception voltage, chemical and electrical properties of the two sampled insulating oils from the transformers had been studied.

Effects of Metal Particle on Dielectric Breakdown of Epoxy Insulation (금속 이물질이 에폭시 절연물의 절연파괴에 미치는 영향)

  • Jang, Yoon-Ki;Lee, Dong-Won;Kim, Jung-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.207-208
    • /
    • 2007
  • Epoxy resin insulators show a lot of advantages for electrical power apparatus. Because epoxy resin provide electrical and mechanical characteristic which is excellent, it is desirable to apply epoxy resin as a spacer and post insulation in Gas Insulated Switchgear (GIS). In this study, we have investigated the influence of surface electric field attached particle contaminated spacer surfaces under SF6 gas. Also, we performed analysis of electric field. As a result, when the particle was attached on spacer, we found out a surface electric field of characteristics.

  • PDF

Current Voltage Characteristic of ZTO Thin Film by Negative Resistance (ZTO 박막의 부성저항에 의한 전류전압특성)

  • Oh, Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.29-31
    • /
    • 2019
  • The ZTO/p-Si thin film was produced and investigated for tunneling phenomena caused by the interface characteristics of the depletion layer. ZTO thin film was deposited and heat treated to produce barrier potentials by the depletion layer. The negative resistance characteristics were shown in the thin film of ZTO heat treated at $100^{\circ}C$, and the insulation properties were the best. Current decreased in the negative voltage direction by nonlinear show key characteristics, and current decreased in tunneling phenomenon by negative resistance in the positive voltage direction. Heat treated at $100^{\circ}C$, the ZTO thin film has increased barrier potential in the areas of the depletion layer and therefore the current has increased rapidly. The current has decreased again as we go beyond the depletion layer. Therefore, tunneling can be seen to make insulation better. In the ZTO thin film heat treated at $70^{\circ}C$ without tunneling, leakage current occurred as current increased at positive voltage. Therefore, tunneling effects by negative resistance were found to enhance insulation properties electrically.

An Analysis of Effects through Improved Insulation Performance for High-Density Residential Area on West High East Low Type (서고동저형 경사지 주거 밀집지역의 단열성능 개선 효과분석)

  • Lee, Seong-Hwa;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.69-78
    • /
    • 2018
  • The purpose of this study is propose eco-friendly remodeling while protecting the living environment of existing residents and preserving the living in pleasant by considering the characteristic of high density sloped residential area. And then, the optimum insulation condition is analyzed based on the energy efficiency, economic analysis and environmental effect. It will be possible as the basic information for remodeling of each housing in sloped area. The energy demanding, cost and the carbon emission reduction is analyzed with the residential area in Seo-gu, Busan by eco-remodelling.

Analysis of electron transport characteristic in He gas by MCS (MCS에 의한 Helium 기체 중의 전자수송특성 해석)

  • Song, Byoung-Doo;Ha, Sung-Chul;Seo, Sang-Hyoen;Moon, Ki-Seok;Yoo, Hoy-Young;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1752-1754
    • /
    • 1998
  • Recently the research about electron transport characteristic and energy distribute function in mixture gases within Helium, has been used and developed widely as industrial quality improvement of extinguish characteristic, electrical dielectric strength ability of application of each species high voltage apparatus, gas plasma etching progress of work to use manufacture of semiconductor, thin film molding by CVD, insulation film to use ultra LSI, etc. This paper analyze electron transport characteristic in the range E/N $1{\sim}60$[Td], pressure $0.1{\sim}6.0$[Torr] by MCS. It is necessary to seek electron drift velocity, diffusion coefficient, lonization coefficients, characteristic energy, mean energy and electron energy distribution function as electron transport characteristic.

  • PDF

An experimental study on the sound insulation and sound absorption characteristics of Korean traditional windows (전통창호 흡·차음 특성에 관한 실험적 연구)

  • Lee, Tai-Kang;Kim, Hang;Song, Gook-Gon;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.8 no.5
    • /
    • pp.3-10
    • /
    • 2008
  • The Korean traditional architecture has developed by adapting to the natural environment, and has successfully created a comfortable indoor settings by using the surrounding natural resources. This is reflected in the building layout, space design and even materials. Our traditional wooden windows adjusting ambient temperature and humidity have both the functions of window and door, although they are clearly divided in the West. The opening and closing method of our traditional windows is similar and their dimensions are shown not to be standardized but diverse in terms of the characteristic of wooden furniture and that of components placed between columns. Thus this study aims to research the sound insulation and absorption performance of traditional windows to be varied with thickness, finishing method of window paper and thickness of air layer. Despite increase of the thickness of window paper, sound absorption was reduced, and the same result was shown when both sides of the structure were finished with thick window paper. The sound insulation performance of the windows could be evaluated to be inappropriate with $R_w$ 0 ~ $R_w$ 14.