• Title/Summary/Keyword: instrument

Search Result 6,394, Processing Time 0.034 seconds

Universal Ethics and Pragmatic Pluralism (보편윤리학과 실용주의적 다원론)

  • Kwon, Su-Hyeon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.1
    • /
    • pp.446-453
    • /
    • 2021
  • This paper deals with two methods regarding fact and value. One is the method of H. Putnam, which is to break the boundary between fact and value and to make a world where the two have an inherent connection. The other is the method of J. Habermas, which regards fact and value as the product of an intersubjective agreement based on argumentation. Putnam, through his position of internal realism, moves from realism to pragmatism, especially by combining the rationalist tradition of Kant and Dewey's pragmatic views. Habermas also stands in the tradition of rationalism and universalism in Kant, at the same time emphasizing the practicability of truth in Hegel's tradition of historical reason. The significance of the strategy of Putnam and Habermas is that they have attempted to revive the realm of value against the strict dichotomy of facts and values and the subsequent devaluation of rationality in the realm of value. The starting point of this attempt is that the practical foundation of rationality is laid on life and practice. This could provide the room for escaping from rationality, which prioritizes only truths that reveal facts, that is, instrument-reduced rationality, the room for the revival of practical rationality through reflection on what is the purpose of life, and, in turn, the room for resisting to pass the realm of values and norms to the logic of habitual routines or customs. However, despite such common goal, there are clear limitations to Putnam's approach due to the differences in the strategies taken on facts and values. Putnam's method can demolish the whole universal framework that is the foundation where pragmatic pluralism will be fostered, eliminating the difference between the specificity of values and the universality of norms and shaking up the status of universal ethics. Therefore, Habermas' ethical theory is proposed as an alternative to establish a basis for universal ethics by relying on communication rationality and to secure the coercion of norms and blossom cultural pluralism as a diverse lifestyle based on this coercion.

The Diaspora Narrative and Aesthetics in Handol's Tarae (한돌 타래의 디아스포라 서사와 미학)

  • Shin, Sa-Bin
    • Journal of Popular Narrative
    • /
    • v.26 no.3
    • /
    • pp.189-219
    • /
    • 2020
  • This study is an analysis of Handol Heung-Gun Lee's Tarae, which is a coinage combining the Korean words for "playing an instrument" and "song", in terms of narrative and aesthetics. The components for analysis are the phenomena and nature of binary oppositions between nature and human beings, between alienation and interest, between division and unification, and between diaspora and people of the national community. Tarae in the period from the late 1970s to the early 1990s described the experience of pain and loss from non-resistance and disobedience in protest against social problems that emerged during the era of miliary dictatorship, such as industrialization, urbanization, reckless development, Westernization, university-oriented education, the gap between rich and poor, human alienation, and the conflicts arising from the division of the nation. After Handol overcame the lack of creative motivation with self-reflection and effort, Tarae took the form of a diaspora epic meta-narratives integrating the "sound of nature and his true nature" and "the awareness of diaspora and the spirit of the Korean people". The epics of the homeland, the national soil and the people, which began with "Teo", became more intense in terms of a sense of diaspora as they shifted their focus from an origin to a path with "Hanmoejulghi" as the turning point. Handol seeks inspiration in the source of narrative rather than in music. His Tarae focuses on "adding rhythm for lyrics". For this reason, the semiotic features of Tarae have a limitation in that its extrinsic phonology is simple even if its intrinsic meaning (i.e., emotion of sadness) is profound and subtle. In order to elicit sympathy from the audience and impress them, it is necessary to strike a balance between the implicit (semantic) part and the explicit (phonological) part. To share the emotion of sadness with more people, it is necessary to strengthen phonological elements. Sympathy for sadness and deep impression on the audience are more often induced by the mood of similar sentiments than by the stories of the same experience. The aesthetics of sadness in Tarae began with the narratives of past experience which were expressed in the contexts of loss, loneliness, and poverty that Handol had experienced since childhood. However, the aesthetics of sadness, deepened over the period of a long hiatus in Handol's career as a composer, formed the narratives of ultimate salvation, embodying even the diaspora experience of others (e.g., displaced people, overseas adoptees, ethnic Koreans in Russia, victims of Japanese military sexual slavery, etc.). This gave Tarae the potential to go beyond the limits of the ethnic group of Korea. Tarae, as a "dispersed sound", can benefit from the appeal of deep sadness at the point of contact with other forms of world music. It may form a global diaspora discourse because Tarae is oriented towards interculturalism rather than anti-multiculturalism. The future challenge and goal of Handol's Tarae would be to continue to find areas of sympathy and broaden the horizon of awareness as diaspora music.

Effects of Conflict Management Strategy Within Supply Chain on Partnership and Performance (공급망 내 갈등관리전략이 파트너십과 성과에 미치는 영향)

  • Ham, Yoon-Hee;Song, Sang-Hwa
    • Korean small business review
    • /
    • v.42 no.1
    • /
    • pp.79-105
    • /
    • 2020
  • While individual enterprises with different objectives each other within supply chains require a variety of resources to achieve their own seeking goals and performances, it is necessary to form interdependent relationships among the enterprises to secure the resources what they need, as the individual enterprises are supposed to have limitations on such as time, space and cost to secure all the resources. In this process, conflict possibilities rise and opportunistic behaviors increase due to those environmental factors such as unbalanced information among enterprises, limited rationality, pursuit of interests, and risk aversion. Those existing studies on conflicts in the field of supply chains have limitations in that they failed to present specific conflict management strategies based on the conflict types from the perspective of the conflict resolution mechanism as the studies have made only focused on investigating the causes of conflicts and the impact of conflicts on performance. In this study, therefore, it used the TKI model of Kilmann and Thomas(1977) to subdivide the conflict management strategies in the process of transactions within supply chains by enterprises, and looked into the impact on partnership and performance according to each strategy. As the results, it showed that those types of conflict management strategies such as concession type and cooperation type had a positive(+) impact on the relationship commitment as a factor of partnership, and it was identified that the relationship commitment had a positive(+) impact on performance. In other words, it can be considered that the enterprises making use of the concession type & the cooperation type conflict management strategies under the situation of conflict would be able to have a very positive impact on their performances if they can make good relationship commitment such as investments in and efforts for the sustainable relationship along with the conflict management, while recognizing the importance of relationship. The most important meaning of this study lies on in terms of that it would be contributable to strengthening the partnership between enterprises and minimizing the risk of supply chains caused by conflicts through these results from the study.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.

A Practical Method to Quantify Very Low Fluxes of Nitrous Oxide from a Rice Paddy (벼논에서 미량 아산화질소 플럭스의 정량을 위한 실용적 방법)

  • Okjung, Ju;Namgoo, Kang;Hoseup, Soh;Jung-Soo, Park
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.285-294
    • /
    • 2022
  • In order to accurately calculate greenhouse gas emissions in the agricultural field, Korea has been developing national-specific emission factors through direct measurement of gas fluxes using the closed-chamber method. In the rice paddy, only national-specific emission factors for methane (CH4) have been developed. It is thus necessary to develop those for nitrous oxide (N2O) affected by the application of nitrogen fertilizer. However, since the concentration of N2O emission from rice cultivation is very low, the QA/QC methods such as method detection and practical quantification limits are important. In this study, N2O emission from a rice paddy was evaluated affected by the amount of nitrogen fertilizer, by taking into account both method detection and practical quantification limits for N2O concentration. The N2O emission from a rice paddy soils affected by the nitrogen fertilizer application was estimated in the following order. The method detection limit (MDL) of N2O concentration was calculated at 95% confidence level based on the pooled standard deviation of concentration data sets using a standard gas with 98 nmol mol-1 N2O 10 times for 3 days. The practical quantification limit (PQL) of the N2O concentration is estimated by multiplying 10 to the pooled standard deviation. For the N2O flux data measured during the rice cultivation period in 2021, the MDL and PQL of N2O concentration were 18 nmol mol-1 and 87 nmol mol-1, respectively. The measured values above the PQL were merely about 12% of the total data. The cumulative N2O emission estimated based on the MDL and PQL was higher than the cumulative emission without nitrogen fertilizer application. This research would contribute to improving the reliability in quantification of the N2O flux data for accurate estimates of greenhouse gas emissions and uncertainties.

Development and Validation of the Korean Implementation Fidelity Checklist of Tier 1 School-Wide Positive Behavior Support (KIFC-T1) (한국형 학교차원 긍정적 행동지원 1차 실행충실도 척도(KIFC-T1)의 개발과 타당화)

  • Nam, Dong Mi;Chang, Eun Jin;Won, Sung-Doo;Cho Blair, Kwang-Sun;Song, Wonyoung
    • Korean Journal of School Psychology
    • /
    • v.17 no.3
    • /
    • pp.401-419
    • /
    • 2020
  • The purpose of this study was to validate the Korean Implementation Fidelity Checklist of Tier 1 School-Wide Positive Behavior Support (KIFC-T1) for use in the Korean educational system. Tier 1 support, which is universal supports, within a multi-tiered, school-wide positive behavior support (SWPBS) model, aims to provide support to and prevent problem behaviors among all students in a school. The initial KIFC-T1 consisted of 48 items and 11 factors and was developed based on a literature review. Its content was validated by experts. The validated KIFC-T1 was introduced to 185 special school teachers who had experience implementing SWPBS and who used the instrument to assess the degree to which their schools had implemented Tier 1 support. Based on their responses, the construct validity of the KIFC-T1 was examined using factor, item, and internal consistency reliability analyses. The concurrent validity of the tool was examined using the PBS Evaluation Tool, School Climate Questionnaire, School Discipline Practice Scale, and PBS Effectiveness Scale. The analyses revealed that KIFC-T1 had a stable five-factor structure with 35 items, had good reliability (Cronbach's α=.956, each factor's Cronbach's α=.834-.951), and its results were statistically significantly correlated with those of the PBS Evaluation Tool, School Discipline Practice Scale, and the PBS Effectiveness Scale. However the KIFC-T1's results were not statistically significantly correlated with the results of the School Climate Questionnaire. These results suggest that KIFC-T1 is a reliable and valid tool for assessing the fidelity of universal support implementations.

THE EFFECT OF THE REPEATABILITY FILE IN THE NIRS EATTY ACIDS ANALYSIS OF ANIMAL EATS

  • Perez Marin, M.D.;De Pedro, E.;Garcia Olmo, J.;Garrido Varo, A.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4107-4107
    • /
    • 2001
  • Previous works have shown the viability of NIRS technology for the prediction of fatty acids in Iberian pig fat, but although the resulting equations showed high precision, in the predictions of new samples important fluctuations were detected, greater with the time passed from calibration development to NIRS analysis. This fact makes the use of NIRS calibrations in routine analysis difficult. Moreover, this problem only appears in products like fat, that show spectrums with very defined absorption peaks at some wavelengths. This circumstance causes a high sensibility to small changes of the instrument, which are not perceived with the normal checks. To avoid these inconveniences, the software WinISI 1.04 has a mathematic algorithm that consist of create a “Repeatability File”. This file is used during calibration development to minimize the variation sources that can affect the NIRS predictions. The objective of the current work is the evaluation of the use of a repeatability file in quantitative NIRS analysis of Iberian pig fat. A total of 188 samples of Iberian pig fat, produced by COVAP, were used. NIR data were recorded using a FOSS NIRSystems 6500 I spectrophotometer equipped with a spinning module. Samples were analysed by folded transmission, using two sample cells of 0.1mm pathlength and gold surface. High accuracy calibration equations were obtained, without and with repeatability file, to determine the content of six fatty acids: miristic (SECV$\sub$without/=0.07% r$^2$$\sub$without/=0.76 and SECV$\sub$with/=0.08% r$^2$$\sub$with/=0.65), Palmitic (SECV$\sub$without/=0.28 r$^2$$\sub$without/=0.97 and SECV$\sub$with/=0.24% r$^2$$\sub$with/=0.98), palmitoleic (SECV$\sub$without/=0.08 r$^2$$\sub$without/=0.94 and SECV$\sub$with/=0.09% r$^2$$\sub$with/=0.92), Stearic (SECV$\sub$without/=0.27 r$^2$$\sub$without/=0.97 and SECV$\sub$with/=0.29% r$^2$$\sub$with/=0.96), oleic (SECV$\sub$without/=0.20 r$^2$$\sub$without/=0.99 and SECV$\sub$with/=0.20% r$^2$$\sub$with/=0.99) and linoleic (SECV$\sub$without/=0.16 r$^2$$\sub$without/=0.98 and SECV$\sub$with/=0.16% r$^2$$\sub$with/=0.98). The use of a repeatability file like a tool to reduce the variation sources that can disturbed the prediction accuracy was very effective. Although in calibration results the differences are negligible, the effect caused by the repeatability file is appreciated mainly when are predicted new samples that are not in the calibration set and whose spectrum were recorded a long time after the equation development. In this case, bias values corresponding to fatty acids predictions were lower when the repeatability file was used: miristic (bias$\sub$without/=-0.05 and bias$\sub$with/=-0.04), Palmitic (bias$\sub$without/=-0.42 and bias$\sub$with/=-0.11), Palmitoleic (bias$\sub$without/=-0.03 and bias$\sub$with/=0.03), Stearic (bias$\sub$without/=0.47 and bias$\sub$with/=0.28), oleic (bias$\sub$without/=0.14 and bias$\sub$with/=-0.04) and linoleic (bias$\sub$without/=0.25 and bias$\sub$with/=-0.20).

  • PDF

Administration of Yijung-tang, Pyeongwi-san, and Shihosogan-tang for Standardization of Korean Medicine Pattern Identification for Functional Dyspepsia: A Study Protocol of a Randomized, Assessor-blind, 3-Arm, Parallel, Open-label, Multicenter Clinical Trial (기능성 소화불량 한의 변증 표준화를 위한 이중탕, 평위산 및 시호소간탕 투여 : 무작위 배정, 평가자 눈가림, 3군 비교, 평행 설계, 공개, 다기관 임상시험 프로토콜)

  • Boram Lee;Min-Jin Cho;Young-Eun Choi;Ojin Kwon;Mi Young Lim;Seok-Jae Ko;So-yeon Kim;Yongjoo Kim;Donghyun Nam;Dong-Jun Choi;Jun-Hwan Lee;Jae-Woo Park;Hojun Kim
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.6
    • /
    • pp.1105-1121
    • /
    • 2022
  • Objectives: The purpose of this study is to explore the effectiveness and safety of frequently used clinical herbal medicines (Yijung-tang [Lizhong-tang, LJT], Pyeongwi-san [Pingwei-san, PWS], and Shihosogan-tang [Chaihu Shugan-tang, SST]) in patients with functional dyspepsia (FD) when administered according to herbal medicine and Korean medicine pattern identification. The results of this study will be used to standardize the diagnostic instrument used in Korean medicine and to investigate biomarkers of Korean medicine pattern identification. Methods: This study will be a randomized, assessor-blind, 3-arm, parallel, open-label, multi-center clinical trial. A total of 300 FD participants will be recruited from 3 Korean medical hospitals and assigned to the LJT (n=100), PWS (n=100), and SST (n=100) groups according to FD pattern identification. The patients will take the medication for 8 weeks, 3 times a day, before or between meals. The primary outcome will be total dyspepsia symptom (TDS) and the secondary outcomes will be adequate relief (AR) for dyspepsia, overall treatment effect (OTE), visual analogue scale (VAS), functional dyspepsia-related quality of life (FD-QoL), gastrointestinal symptom score (GIS), and pattern identification questionnaires. For the exploratory outcomes, we will analyze blood and fecal metabolome profiles, microbiota from fecal and saliva samples, single nucleotide polymorphism (SNP), and results of Korean medicine diagnosis device measurements (heart rate variability, and tongue, pulse, and abdominal diagnosis). Conclusions: The results of this study will prove objectivity for Korean medicine pattern identifications, and the effectiveness and safety of herbal medicines for the population with FD.

Study on Causes and Countermeasures for the Mass Death of Fish in Reservoirs in Andong-si (안동시 저수지에서의 대량 어류 폐사에 대한 원인과 대책에 관한 연구)

  • Su Ho Bae;Sun Jin Hwang;Youn Jung Kim;Cheol Ho Jeong;Seong Yun Kim;Keon Sang Ryoo
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.1
    • /
    • pp.52-62
    • /
    • 2023
  • This study focused on determining the specific causes and prevention methods of mass fish deaths occurred in five reservoirs (Gagugi, Neupgokgi, Danggokgi, Sagokji, and Hangokji) in Andong-si. For this purpose, a survey of agricultural land and livestock in the upper part of the reservoirs and analysis of water quality in the reservoir irrespective of whether it rains or not were conducted. We attempted to examine the changes in dissolved oxygen (DO) in the surface and bottom layers of reservoirs and changes in DO depending on the amount of livestock compost and time. Based on the above investigations, treatment plans were established to efficiently control the inflow of contaminated water into reservoirs. The rainfall and farmland areas in the upper part of the reservoir were investigated using Google and aviation data provided by the Ministry of Land, Infrastructure, and Transport. The current status of livestock farms distributed around the reservoirs was also examined because compost from these farms can flow into the reservoir when it rains. Various water quality parameters, such as phosphate phosphorus (PO4-P) and ammonium nitrogen (NH3-N), were analyzed and compared for each reservoir during the rainy season. Changes in the DO concentration and electrical conductivity (EC) were also observed at the inlet of the reservoir during raining using an automated instrument. In addition, DO was measured until the concentration reached 0 ppm in 10 min by adding livestock compost at various concentrations (0.05%, 0.1%, 0.3%, and 0.5% by wt.), where the concentration of the livestock compost represents the relative weight of rainwater. The DO concentration in the surface layer of reservoirs was 3.7 to 5.3 ppm, which is sufficient for fish survival. However, the fish could not survive at the bottom layer with DO concentration of 0.0-2.1 ppm. When the livestock compost was 0.3%, DO required 10-19 h to reach 0 ppm. Considering these results, it was confirmed that the DO in the bottom layer of the reservoir could easily change to an anaerobic state within 24 h when the livestock compost in the rainwater exceeds 0.3%. The results show that the direct cause of fish mortality is the inflow of excessive livestock compost into reservoirs during the first rainfall in spring. All the surveyed reservoirs had relatively good topographical features for the inflow of compost generated from livestock farms. This keeps the bottom layer of the reservoir free of oxygen. Therefore, to prevent fish death due to insufficient DO in the reservoir, measures should be undertaken to limit the amount of livestock compost flowing into the reservoir within 0.3%, which has been experimentally determined. As a basic countermeasure, minerals such as limestone, dolomite, and magnesia containing calcium and magnesium should be added to the compost of livestock farms around the reservoir. These minerals have excellent pollutant removal capabilities when sprayed onto the compost. In addition, measures should be taken to prevent fish death according to the characteristics of each reservoir.

Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments (척추경 나사못 고정술을 이용한 단일 흉추 청소년기 특발성 척추 측만증의 치료: 스테인리스강과 티타늄 합금 기기의 비교)

  • Kim, Sung-Soo;Lim, Dong-Ju;Kim, Jung-Hoon;Choi, Byung-Wan;Kim, Hwi-Young;Lee, Jun-Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2019
  • Purpose: To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. Materials and Methods: A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative followup were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups. Results: In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05). Conclusion: When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.