• 제목/요약/키워드: inspection projector

검색결과 9건 처리시간 0.019초

원격제어 기능을 갖는 고해상력 투영검사기 개발 (Development of Inspection Projector with Remote-control Function)

  • 이시현
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2010년도 제42차 하계학술발표논문집 18권2호
    • /
    • pp.199-201
    • /
    • 2010
  • 본 논문에서는 광케이블과 소형렌즈를 검사하기 위한 고해상력 투영검사기를 개발하였다. 개발된 고해상력 투영검사기는 30V/7A 전원장치에서 할로겐램프를 연결하여 원격장치로 램프의 밝기를 조절한다. 개발된 고해상력투영검사기는 관련기술을 확보하였고 수입대체효과를 가져올 수 있다.

  • PDF

Remote NDT for Inspection of Reactor Vessel Components of fast Breeder Test Reactor

  • Anandapadmanaban, B.;Srinivasan, G.;Kapoor, R.P.
    • 비파괴검사학회지
    • /
    • 제23권5호
    • /
    • pp.520-525
    • /
    • 2003
  • Fast Breeder Test Reactor (FBTR) is a 40MW (thermal) / 13.2MW (electrical), Plutonium - Uranium mixed carbide fuelled, sodium cooled, loop type nuclear reactor operating at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam. Its main aim is to generate experience in operation of fast reactors and sodium systems and to serve as an irradiation facility for development of fuels and structural materials fur fast reactors. Nuclear reactors pose difficulties to the NDT techniques used to monitor the conditions of the internal components. Sodium cooled fast breeder reactors have their own typical difficulties in using the NDT techniques. These are due to the need for operation in aggressive environment of nuclear radiation and sodium (molten/vapour), as well as the need to maintain leak tightness of a very high order during all states of reactor operation and shutdown for fuel handling, maintenance and remote inspection. This paper discusses the following NDT techniques, which have been successfully used for the past 15 years in FBTR: (i) Periscope and Projector, (ii) Core Co-ordinate Measuring Device and, (iii) Optical fiberscope. The inspection using these techniques have given confidence for further reactor operation at high power by giving useful data on the conditions of the components inside the reactor vessel.

위상측정법을 이용한 LED Package의 3차원 형상 측정 (3-D Measurement of LED Packages Using Phase Measurement Profilometry)

  • 구자명;조태훈
    • 반도체디스플레이기술학회지
    • /
    • 제10권1호
    • /
    • pp.17-22
    • /
    • 2011
  • LEDs(Light Emitting Diodes) are becoming widely used and increasingly in demand. Quality inspection of the LEDs has become more important. Two-dimensional inspection systems are limited in inspection capability, so threedimensional(3-D) inspection systems are needed. In this paper, a cost-effective and simple 3-D measurement system of LED packages using phase measuring profilometry(PMP) is proposed. The proposed system uses a pico projector to project sinusoidal fringe patterns and to shift phases instead of piezocrystal. It was evaluated using extremely accurate gauge blocks, yielding excellent repeatability of about 12 um(3-sigma). 3-D measurements of various LED packages were performed to demonstrate the applicability and efficiency of the proposed system.

레이저 선 프로젝터와 USB 카메라를 이용한 자동차용 철 밸런스 웨이트의 결합상태 검사 (Inspection of combination quality for automobile steel balance weight using laser line projector and USB camera)

  • 최경진;박세제;임호;박종국
    • 반도체디스플레이기술학회지
    • /
    • 제12권1호
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, sensor system and inspection algorithm in order to inspect steel balance weight for automobile is described. Steel balance weight is composed of clip and weight, which is joined by press process. The defective one has a gap between clip and weight. To detect whether there is a gap, sensor system is simply configured with laser line projector and USB camera, which make it possible to measure the height difference of clip and weight area. Laser line pattern which is made on the surface of a balance weight is captured by USB camera. In case that USB camera is used in machine vision, barrel distortion caused by wide angle lens makes the captured image distorted. Image warping function is applied to correct the distortion. Simple image processing algorithm is applied to extract the laser line information and whether it is good or not is judged through the extracted information.

다중 슬릿광을 이용한 3차원 Solder Paste 검사 시스템 (A 3D Solder Paste Inspection System Using Multiple Slit Rays)

  • 조태훈;허병회
    • 제어로봇시스템학회논문지
    • /
    • 제8권2호
    • /
    • pp.151-157
    • /
    • 2002
  • A 3-dimenstional automatic solder paste inspection system is described that can be used to find defects occurring in solder paste printing process. This system extracts height and volume information very fast as well as area of solder paste printed, using multiple slit ray projection and Galvano-mirror scanning. Methods are presented on calibration of camera and slit projector, real-time image processing of multiple slit images, determination of reference height, and extraction of paste height information are proposed. Performance of the system was successfully demonstrated through field tests.

Development of Structured Light 3D Scanner Based on Image Processing

  • Kim, Kyu-Ha;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제11권4호
    • /
    • pp.49-58
    • /
    • 2019
  • 3D scanners are needed in various fields, and their usage range is greatly expanded. In particular, it is being used to reduce costs at various stages during product development and production. Now, the importance of quality inspection in the manufacturing industry is increasing. Structured optical system applied in this study is suitable for measuring high precision of mold, press work, precision products, etc. and economical and effective 3D scanning system for measuring inspection in manufacturing industry can be implemented. We developed Structured light 3D scanner which can measure high precision by using Digital Light Processing (DLP) projector and camera. In this paper, 3D image scanner based on structured optical system can realize 3D scanning system economically and effectively when measuring inspection in the manufacturing industry.

다면 영상을 위한 캘리브레이션 시스템 개발 (Calibration System Development for Multi-Image)

  • 한정수;김귀정
    • 디지털융복합연구
    • /
    • 제14권8호
    • /
    • pp.305-311
    • /
    • 2016
  • 자동화된 영상 캘리브레이션 시스템은 비전문가의 입장에서 다면 영상의 캘리브레이션 기능이 수행된다면, 지금까지 모든 경우에 전문가만을 필요로 하던 비효율적인 운영에서 반드시 필요한 경우에만 전문가를 필요로 할 수 있으므로 시스템 운영에 신속한 운영뿐만 아니라 효율적인 인력운영이 가능하다. 각 프로젝터의 상태 점검 및 관리 기술과 SW 플러그인 형식의 보정 필터링 기능을 수행하는 영상 보정 기술의 결합은 특수 영상관 시스템의 유지보수를 획기적으로 관리할 수 있는 방안이 될 뿐만 아니라 영상 분석 기술과의 결합으로 기술적 완성도를 높일 수 있는 시너지 효과를 기대할 수 있다. 본 논문은 영상의 열화 현상으로 영상관의 품질과 유지보수의 어려움을 해결하기 위해 10비트 High-depth 및 고해상도 $360^{\circ}$ 프로젝션 영상 분석 기술을 개발함으로써 경제적 손실을 최소화하고, 영상의 품질을 효율적으로 지원할 수 있는 특수영상관 캘리브레이션 시스템의 개발을 목표로 한다.

비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구 (The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT)

  • 김교태;김주희;한무재;허예지;안기정;박성광
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.171-175
    • /
    • 2017
  • 비파괴검사 분야에서는 작업자들의 안전을 확보하기 위해 방사선원에 대한 시스템 개발에 많은 시간과 재원을 투자하고 있으나 아직까지 사고 발생 확률은 높은 실정이다. 방사선에 대한 잠재적 사고를 미연에 방지하기 위해서는 방사선원의 위치를 직접적으로 검증하는 것이지만 아직까지 연구가 미흡한 실정이다. 이에 본 연구에서는 감마선조사기의 선원 가이드 튜브에서 방사선원의 위치를 감지할 수 있는 모니터링 시스템 개발을 위한 선행연구로써 몬테카를로 시뮬레이션을 통해 방사선 검출기에 대한 특성을 모의 추정하였다. 연구 결과, Ir-192의 감마선 에너지에 대한 방사선 검출기는 반도체 소재에 무관하게 $150{\mu}m$에서 2차 전자평형이 이루어지는 것으로 분석되었으며, 감마선 응답 특성은 $HgI_2$가 가장 우수할 것으로 기대된다. 이러한 결과는 차후 모니터링 시스템의 검출부에 위치하는 방사선 검출기의 최적화 두께를 결정하는데 기초자료로써 활용될 수 있을 것으로 기대되며, 이를 바탕으로 모니터링 시스템을 개발 시 방사선작업종사자가 위험을 쉽게 인지하여 안전을 확보할 수 있을 뿐만 아니라 잠재적인 방사선 사고에 대한 예방 및 선제적 대응이 가능함으로써 사회 안전망 구축 에 기여할 수 있을 것이다.

비파괴검사 분야에서 방사선원의 위치 확인을 위한 산화납 기반 방사선 검출기 설계에 관한 연구 (The Study on Design of lead monoxide based radiation detector for Checking the Position of a Radioactive Source in an NDT)

  • 안기정
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.183-188
    • /
    • 2017
  • 최근, 감마선 조사기의 자동 원격 조사 제어기가 오동작하여 방사선작업종사자가 방사선 피폭 사고가 지속적으로 보고되고 있다. 이에 NDT 분야에서는 방사선에 대한 잠재적 사고를 미연에 방지하기 위한 방사선원 모니터링 시스템 구축에 많은 시간과 재원을 투자하고 있다. 이에 본 연구에서는 다양한 비파괴검사장비에 범용적으로 적용할 수 있는 방사선원 위치 모니터링 시스템의 개발을 위한 선행연구로써 몬테카를로 시뮬레이션을 통해 산화납 기반 방사선 검출기에 대한 감마선 응답 특성을 모의 추정하였다. 연구 결과, 방사선 검출기의 최적화 두께는 방사선원에서 방사되는 감마선 에너지에 따라 상이하며 에너지가 증가함에 따라 최적화 두께가 점차 증가하는 것으로 나타났다. 결론적으로 PbO 기반 방사선 검출기의 최적화 두께는 Ir-192에 대하여 $200{\mu}m$, Se-75 $150{\mu}m$, Co-60 $300{\mu}m$로 분석되었다. 이러한 연구 결과를 바탕으로 범용적으로 적용하기 위하여 2차 전자 평형을 고려한 PbO 기반 방사선 검출기의 적절한 두께는 $300{\mu}m$로 평가되었다. 이러한 결과는 차후 다양한 NDT 장비에 범용적으로 적용하기 위한 방사선원 위치 모니터링 시스템을 개발 시 방사선 검출기에서 요구되는 적절한 두께를 결정하는데 있어 기초자료로 활용될 수 있을 것으로 사료된다.