• Title/Summary/Keyword: infrared thermal measurement

Search Result 138, Processing Time 0.03 seconds

Analysis of Temperature Change by Forest Growth for Mitigation of the Urban Heat Island (도시열섬 완화를 위한 녹지증가에 따른 온도변화 분석)

  • Yun, Hee Cheon;Kim, Min Gyu;Jung, Kap Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.2
    • /
    • pp.143-150
    • /
    • 2013
  • Recently, environmental issues such as climate warming, ozone layer depletion, reduction of tropical forests and desertification are emerging as global environmental problems beyond national problems. And international attention and effort have been carried out in many ways to solve these problems. In this study, the growth of green was calculated quantitatively using the technique of remote sensing and temperature change was figured out through temperature extraction in the city. The land-cover changes and thermal changes for research areas were analyzed using Landsat TM images on May 2002 and May 2009. Surface temperature distribution was calculated using spectral degree of brightness of Band 6 that was Landsat TM thermal infrared sensor to extract the ground surface temperature in the city. As a result of research, the area of urban green belt was increased by $2.87km^2$ and the ground surface temperature decreased by $0.6^{\circ}C{\sim}0.8^{\circ}C$ before and after tree planting projects. Henceforth, if the additional study about temperature of downtown is performed based on remote sensing and measurement data, it will contribute to solve the problems about the urban environment.

The Influence of Hydrotalcite Intercalated with Benzoate on UV Stability of Acrylic Coating

  • Nguyen, Thuy Duong;Nguyen, Anh Son;Thai, Thu Thuy;Pham, Gia Vu;To, Thi Xuan Hang;Olivier, Marie-Georges
    • Corrosion Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.16-22
    • /
    • 2020
  • It is important to realize that benzoate was intercalated into hydrotalcite (HTC-Bz) by the co-precipitation method. In this case, acrylic coating with 0.5 wt% HTC-Bz was deposited on carbon steel using the spin coating method. Next, the HTC-Bz structure was characterized by Field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). In fact, an ultraviolet vision spectroscopy (UV-Vis) was used to determine the benzoate content in HTC-Bz, and the UV absorption ability of HTC-Bz. Using electrochemical techniques, water contact angle measurement, and thermal-gravimetric analysis, we compared the protective properties before and after QUV test, hydrophobicity and the thermal stability of acrylic coating containing HTC-Bz. The obtained results showed that HTC-Bz with a plate-like structure was successfully synthesized; benzoate was intercalated into the interlayer of hydrotalcite with a concentration of 28 wt%. Additionally, it was noted that HTC-Bz has an UV absorption peak at 225 nm. In conclusion, the addition of HTC-Bz enhanced the UV stability, hydrophobicity and the thermal stability of acrylic coating.

A Study on the Thermal Flow Analysis for Heat Performance Improvement of a Wireless Power Charger (열 유동해석을 통한 무선충전기 발열 성능 향상에 관한 연구)

  • Kim, Pyeong-Jun;Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.310-316
    • /
    • 2019
  • In automotive application, customers are demanding high efficiency and various functions for convenience. The demand for these automotive applications is steadily increasing. In this study, it has been studied the analysis of heat flow to improve the PCB(printed circuit board) heating performance of WPC (wireless power charger) recently developed for convenience. The charging performance of the wireless charger has been reduced due to power dissipation and thermal resistance of PCB. Therefore, it has been proposed optimal PCB design, layout and position of electronic parts through the simulation of heat flow analysis and PCB design was analyzed and decided at each design stage. Then, the experimental test is performed to verify the consistency of the analysis results under actual environmental conditions. In this paper, The PCB modeling and heat flow simulation in transient response were performed using HyperLynx Thermal and FloTHERM. In addition, the measurement was performed using infrared thermal imaging camera and used to verify the analysis results. In the final comparison, the error between analysis and experiment was found to be less than 10 % and the heating performance of PCB was also improved.

Dynamic Quasi-Elastic Light Scattering Measurement of Biological Tissue

  • Youn, Jong-In;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.169-173
    • /
    • 2007
  • During laser irradiation, mechanically deformed cartilage undergoes a temperature dependent phase transformation resulting in accelerated stress relaxation. Clinically, laser-assisted cartilage reshaping may be used to recreate the underlying cartilaginous framework in structures such as ear, larynx, trachea, and nose. Therefore, research and identification of the biophysical transformations in cartilage accompanying laser heating are valuable to identify critical laser dosimetry and phase transformation of cartilage for many clinical applications. quasi-elastic light scattering was investigated using Ho : YAG laser $(\lambda=2.12{\mu}m\;;\;t_p\sim450{\mu}s)$ and Nd:YAG Laser $(\lambda=1.32{\mu}m\;;\;t_p\sim700{\mu}s)$ for heating sources and He : Ne $(\lambda=632.8nm)$ laser, high-power diode pumped laser $(\lambda=532nm)$, and Ti : $Al_2O_3$ femtosecond laser $(\lambda=850nm)$ for light scattering sources. A spectrometer and infrared radiometric sensor were used to monitor the backscattered light spectrum and transient temperature changes from cartilage following laser irradiation. Analysis of the optical, thermal, and quasi-elastic light scattering properties may indicate internal dynamics of proteoglycan movement within the cartilage framework during laser irradiation.

Study in Mechanism of Hydrogen Retention by C-SiC Films with IR

  • Huang, N.K.;Xiong, Q.;Liu, Y.G.;Yang, B.;Wang, D.Z.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.1
    • /
    • pp.46-50
    • /
    • 2002
  • C-SiC films with different content of SiC on stainless steel substrate were prepared with ion beam mixing. It was found that hydrogen concentrations in C-SiC coatings was higher than that in stainless steel after H$\^$+/ ion implantation followed by thermal annealing. Infrared (IR) transmission measurement was used to study the mechanism of hydrogen retention by C-SiC films. The vibrational features in the range between 400 and 3200 cm$\^$-1/ in IR transmission spectra show the Si-CH$_3$, Si-CH$_2$, Si-H, CH$_2$and CH$_3$bonds, which are responsible for retaining hydrogen.

  • PDF

Stabilization, Carbonization, and Characterization of PAN Precursor Webs Processed by Electrospinning Technique

  • Cho, Chae-Wook;Cho, Dong-Hwan;Ko, Young-Gwang;Kwon, Oh-Hyeong;Kang, Inn-Kyu
    • Carbon letters
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2007
  • In the present study, electrospun PAN precursor webs and the stabilized and carbonized nanofiber webs processed under different heat-treatment conditions were characterized by means of weight loss measurement, elemental analysis, scanning electron microscopy (SEM), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), differential scanning calorimetry (DSC), thermogravimentric analysis (TGA), and X-ray diffraction (XRD) analysis. The result indicated that stabilization and carbonization processes with different temperatures and heating rates significantly influenced the chemical and morphological characteristics as well as the thermal properties of the stabilized and then subsequently carbonized nanofiber webs from PAN precursor webs. It was noted that the filament diameter and the carbon content of a carbonized nanofiber web as well as its weight change may be effectively monitored by controlling both stabilization and carbonization processes.

Exceptional removal capacity of clenbuterol from aqueous solution by mechano-synthesized [Cu (INA)2]-MOF via ball-mill

  • Marinah Mohd, Ariffin;Usman, Armaya'u;Saw Hong, Loh;Wan Mohd Afiq Wan Mohd, Khalik;Hanis Mohd, Yusoff
    • Membrane and Water Treatment
    • /
    • v.13 no.6
    • /
    • pp.321-335
    • /
    • 2022
  • Copper-based Metal-organic framework (MOF) namely ([Cu (INA)2]-MOF) is synthesized by ball milling and characterized using scanning electron microscopy (SEM) for the topography, microstructure, and elemental evidence determination, powdered X-ray diffraction (XRD) for the crystallinity measurement, thermogravimetric (TG) analysis was performed to determine the thermal stability of the material, and Fourier transformed infrared (FTIR) spectroscopy for functional groups identification. The use of [Cu (INA)2]-MOF as hazardous removal material of β-agonists as persistent hazardous micro-pollutants in our environmental water is first reported in this study. The removal efficiency of the Cu-MOF is successfully determined to be 97.7% within 40 minutes, and the MOF has established an exceptional removal capacity of 835 mg L-1 with 95 % percent removal on Clenbuterol (CLB) even after the 5th consecutive cycle. The Langmuir model of the adsorption isotherms was shown to be more favourable, while the pseudo-second-order model was found to be favoured in the kinetics. The reaction was exothermic and spontaneous from a thermodynamic standpoint, and the higher temperatures were unfavourable for the adsorption study of the CLB. As a result, the studied MOF have shown promising properties as possible adsorbents for the removal of CLB in wastewater.

Thermal Oxidation of Porous Silicon (다공질 실리콘 (Porous Silicon) 의 열산화)

  • Yang, Cheon-Soon;Park, Jeong-Yong;Lee, Jong-Hyun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.10
    • /
    • pp.106-112
    • /
    • 1990
  • The progress of oxidation of a porous silicon layer(PSL) was studied by examining the temperature dependence of the oxidation and the infrared absorption spectra. Thick OPSL(oxidized porous silicon layer). which has the same properties as thermal $SiO_{2}$ of bulk silicon, is formed in a short time by two steps wet oxidation of PSL at $700^{\circ}C$, 1 hr and $1100^{\circ}C$, 1 hr. Etching rate, breakdown strength of the OPSL are strongly dependent on the oxidation temperature, oxidation atmosphere. And its breakdown field was ${1\MV/cm^-2}$ MV/cm The oxide film stress was determined through curvature measurement using a dial gauge. During oxidation at temperature above $1000^{\circ}C$ in dry $O_{2}$, stress on the order of ${10^9}\dyne/{cm^2}{-10^10}\dyne/{cm^2}$ are generated in the OPSL.

  • PDF

Research of Non-integeral Spatial Interpolation for Precise Identifying Soybean Location under Plastic Mulching

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.156-156
    • /
    • 2017
  • Most crop damages have been occurred by vermin(e.g., wild birds and herbivores) during the period between seeding and the cotyledon level. In this study, to minimize the damage by vermin and acquire the benefits such as protection against weeds and maintenance of water content in soil, immediately vinyl mulching after seeding was devised. Vinyl mulching has been generally covered with black color vinyl, that crop seeding locations cannot be detected by visible light range. Before punching vinyl, non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. For this study, the spline method was relatively faster than the other polynomial interpolation methods, because it has a lower maximum order of formulation when using a system such as the tridiagonal linear equation system which provided the capability of real-time processing. The temperature distribution corresponding to the distance between the crops was 10 cm, and the more clearly the leaf pattern of the crop was visually confirmed. The frequency difference was decreased, as the number of overlapped pixels was increased. Also the wave pattern of points where the crops were recognized were reduced.

  • PDF

Study on the Possibility of Quantitative Measurement of Abdominal Examinations in Korean Medicine - A Focus on Diagnosis of Abdominal Coldness in Functional Dyspepsia Patients - (한의 복진 정량화 연구 - 기능성 소화불량 환자의 복냉 진단을 중심으로 -)

  • Lee, Jae-hong;Cho, Soo-ho;Ko, Seok-jae;Kim, Jin-sung;Park, Jae-woo
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.495-510
    • /
    • 2018
  • Objective: This study was designed to investigate the possibility of quantification of the diagnosis of abdominal coldness (AC) in patients with functional dyspepsia (FD). Methods: Forty-four patients with FD were enrolled in this study. Three Korean medicine doctors each randomly examined all abdomens. Diagnosis of AC was made by consensus of at least two of the doctors. Body temperature (oral by digital oral thermometer) and skin temperature (by digital infrared thermal imaging [DITI]) were measured, followed by administration of the Cold and Heat questionnaire (CHQ) and the Instrument of Pattern Identification for Functional Dyspepsia (IPIFD). Results: Of the 44 patients with FD, 22 were assigned to the AC group and 22 to the non-AC group. The concordance rate of diagnosis among the three doctors was 63.6% (28/44), with a ${\kappa}$ of 0.504, indicating means moderate agreement). Neither the oral nor the skin temperatures showed statistically significant differences between the AC and non-AC groups. However, the CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD were higher in AC group and showed statistically significant differences (p=0.010 and 0.009). Conclusions: This is the first study conducting quantitative measurements of abdominal coldness in patients with FD. Although oral and skin temperature showed no statistical significance between AC and non-AC groups, the concordance rate of diagnosis of AC among the three Korean Medicine doctors was moderate. The CHQ scores and 'Simultaneous Occurrence of Cold and Heat Syndromes pattern' scores of the IPIFD also suggest that diagnosis of AC is relevant to cold and heat patterns, and these questionnaires could be utilized as supportive data for the diagnosis of AC. Further studies should be conducted for the purpose of quantifying and standardizing abdominal examinations in Korean Medicine.