• Title/Summary/Keyword: industrial safety

Search Result 10,244, Processing Time 0.031 seconds

Characteristic study and isolation of Bacillus subtilis SRCM 101269 for application of cow manure (우분 적용을 위한 Bacillus subtilis SRCM 101269의 분리 및 특성 연구)

  • Jeon, SaeBom;Oh, HyeonHwa;Uhm, Tai-Boong;Cho, Jae-Young;Yang, Hee-Jong;Jeong, Do-Youn
    • Korean Journal of Microbiology
    • /
    • v.52 no.1
    • /
    • pp.74-83
    • /
    • 2016
  • Bacillus subtilis SRCM 101269 having safety and amo gene isolated from Korean traditional fermented food and their investigated characterization to apply the cow manure such as cellulase and xylanase activities, 16S rRNA sequencing, and ability of removal of livestock manure odor. Cow manure application results for the removal of livestock manure odor, the ammonia gas was reduced more than two-folder compared to the control group after 6 days, and reduced to less than 10 ppm after 9 days. In the case of cow manure added fowl droppings and other wood-based mixture components, ammonia gas maintained constant after 3 days of fermentation. However, in the case of sample inoculated B. subtilis SRCM 101269, ammonia gas reduced in course of fermentation time, and concentration of hydrogen sulfide also reduced for 65 ppm. Changes of nitrite concentration according to fermentation time no showed different for cow manure, however nitrite concentration in mixed livestock manure increased when compared to control. And then sulfate concentration in cow manure decreased, and no showed different when compared to the initial fermentation. No apparent change of sulfate concentration in mixed livestock manure detected. Through the previously studies, B. subtilis SRCM 101269 has high potential in industrial application manufacturing the cow manure as removal of livestock manure odor.

A Design of Secure Communication for Device Management Based on IoT (사물인터넷 기반 디바이스 관리를 위한 안전한 통신 프로토콜 설계)

  • Park, Jung-Oh;Choi, Do-Hyeon;Hong, Chan-Ki
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.55-63
    • /
    • 2020
  • The IoT technology is a field that applies and converges the technologies in the existing industrial environment, instead of new technologies. The IoT technology is releasing various application services converged with other industries such as smart home, healthcare, construction, and automobile, and it is also possible to secure the work efficiency and convenience of users of IoT-based technologies. However, the security threats occurring in the IoT-based technology environment are succeeding to the vulnerability of the existing wireless network environment. And the occurrence of new and variant attacks in the combination with the ICT convergence environment, is causing damages. Thus, in the IoT technology-based environment, it would be necessary to have researches on the safe transmission of messages in the communication environment between user and device, and device and device. This thesis aims to design a safe communication protocol in the IoT-based technology environment. Regarding the suggested communication protocol, this thesis performed the safety analysis on the attack techniques occurring in the IoT technology-based environment. And through the performance evaluation of the existing PKI-based certificate issuance system and the suggested communication protocol, this thesis verified the high efficiency(about 23%) of communication procedure. Also, this thesis verified the reduced figure(about 65%) of the issued quantity of certificate compared to the existing issuance system and the certificate management technique.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

Experimental Study of a Seismic Reinforcing System without Power Interruption and Movement for Electric Panel on the Access Floor (무정전-무이설 방식의 전기판넬 내진보강시스템 시험연구)

  • Jang, Jung-Bum;Lee, Jong-Rim;Hwang, Kyeong-Min;Ham, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The seismic reinforcing system is developed to prevent damage to electric panels which are installed on the access floor and are essential to the operation of various basic facilities such as electric power and communication etc., from earthquakes. The seismic capacity of seismic reinforcing system is verified through the shaking table test. The seismic reinforcing system is intended for the electric panel on the access floor, and installation is possible without movement and power interruption of the electric panel. The enveloped response spectrum is adopted considering the location of the electric panel in the building as input motion for the shaking table test. The shaking table tests are carried out with two electric panels that can be considered representative of general electric panels, and two types of access floors such as wood panel and steel panel, which are commonly used in the industrial field. As a result of tests, it is confirmed that the seismic reinforcing system secures the seismic safety of electric panels by preventing the overturning of electric panels during and after the shaking table tests. In the event that the seismic reinforcing system is applied to the electric panel on the access floor, damage to the electric panel from an earthquake can be effectively prevented, which can greatly contribute to the stable operation of domestic basic facilities.

Geosynthetic Reinforced Soil Method for Restoration of Debris Flow Failure Slopes (쇄설성 유동파괴 사면 복구를 위한 토목섬유 보강토 공법)

  • Cho Yong-Seong;Kim You-Seong;Park Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.93-101
    • /
    • 2005
  • The formation of slopes is unavoidable under the special circumstance of Korea where $7%$ of the whole area are composed of mountains and civil engineering projects such as road and site developments are increasing with industrial development and horizontal expansions of urban area. Stability of slopes is one of quite important issues under special meteorological characteristics that over two-thirds of annual average rainfall is concentrated in summer season and the localized torrential downpour is getting more frequent recently. As a result of these circumstances, partial slope failures by debris flow of the high water content soils occur frequently in cut soil slopes. In this case of debris flow slope failure, slope declination method is selected fur the stable recovery because it is impossible to recover entirely by existing recovery methods. Seeding or special grass planting methods are followed separately without exception. The method by which entire recover with bigger stability ratio would be possible and grass planting work would be done simultaneously is developed. For debris flow failure slopes, this study secured the safety of slopes by preventing the inflow of rainwater and scour using geosynthetics-reinforced embankment, and created nature-friendly slopes by planting trees on the slopes.

A Study on Development of Remote Crane Wire Rope Flaws Detection Systems (원격 크레인 와이어 로프 결함 탐지 시스템 개발에 관한 연구)

  • Min, Jeong-Tak;Lee, Jin-Woo;Lee, Kwon-Soon
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, the wire rope of crane is important component to container transfer. If it happens wire rope failures during the operation, it may lead to safety accident, economic loss by productivity decline and so on. To solve this problem, we developed remote wire rope fault detecting system, and this system is consisted of 3 parts that portable fault detecting part, signal processing part and remote monitoring part. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data. It is verified that the detecting system by de-noising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension fo wire ropes exchange period and could competitive power. Also, this system is possible to apply in several field such as elevator, lift and so on.

Comparative Studies of Thermal Insulation Performance of Life Vests by Numerical Analysis and Experiment (보온 재료에 따른 구명 조끼 별 단열성능의 비교 실험 및 해석)

  • Kim, Sung-Chan;Lee, Kyung-Hoon;Hwang, Se-Yun;Jang, Ho-Sang;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Although the life jacket can provide the buoyance with the drowner, heat loss can make the drowned individual be subject to the hypothermia. In this study, The thermal insulation of two types life jacket including inflatable and foam type were evaluate by both experiments and numerical analysis. To estimate the thermal resistance of the jackets, experiments on the heat flux were conducted by the thermal manikin exposed to cold water. Heat flux loss on the surface of thermal manikin were measured for both foam and inflatable type life jacket. Also, finite element method is applied to a body section in order to understand the level of hypothermia of each life jacket. The segmental of human thigh is represented by a multi-layered section which considers the heat conduction within tissue, bone and fat. As a result, the thermal resistance and hypothermia time of each jackets have been compared based on the finite element analysis. It was found that the insulation ability of suggested life jackets is better than that of conventional type.

[Retraction] Preparation of Methyl methacrylate/styrene Core-shell Latex by Emulsion Polymerization ([논문 철회] 유화중합에 의한 Methyl methacrylate/styrene계 Core-shell 라텍스 입자 제조에 관한 연구)

  • Kang, Don-O;Lee, Nae-Woo;Seul, Soo-Duk;Lee, Sun-Ryong
    • Elastomers and Composites
    • /
    • v.37 no.1
    • /
    • pp.21-30
    • /
    • 2002
  • Core-shell polymers of methyl methacrylate/styrene pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl benzene sulfonate(SDBS) as an emulsifier using ammonium persulfate(APS) as an initiator. The characteristics of these core-shell polymers were evaluated. Core-shell composite latex has the both properties of core and shell components in a particle, where as polymer blonds or copolymers show a combined properties from the physical properties or two homopolymers. This unique behavior of core-shell composite latex can be used in many industrial fields. However, in preparation of core-shell composite latex, several unexpected phenomina are observed, such as, particle coagulation, low degree of polymerization, and formation of new particles during shell polymerization. To solve the disadvantages, we studied the effects of surfactant concentrations, initiator concentrations, and reaction temperature on the tore-shell structure or PMMA/PSt and PSt/PMMA. Particle size and particle size distribution were measured by using particle size analyzer, and the morphology of the core-shell composite latex was observed by using transmission electron microscope. Glass transition temperature($T_g$) was also measured by using differential scanning calorimeter. To identify the core-shell structure, pH of the composite latex solutions were measured.

Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures (철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측)

  • Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2011
  • Reliability of piping systems is essential to the safety of any important industrial facilities. During an earthquake, damage to the piping system can occur. It can also cause considerable economic losses and the loss of life following earthquakes. Traditionally, the study of the secondary system was less important than primary structure system, however it has recently been emerging as a key issue for the effective maintenance of the structural system and to help reduce nonstructural earthquake damage. The primary objectives of this study are to evaluate seismic design requirements and the seismic performance of gas and fire protection piping systems installed in reinforced concrete (RC) buildings. In order to characterize the seismic behavior of the existing piping system in an official building, 10 simulated earthquakes and 9 recorded real earthquakes were applied to ground level and the building system by the newmark average acceleration time history method. The results developed by this research can be used for the improvement of new seismic code/regulatory guidelines of secondary systems as well as the improvement of seismic retrofitting or the strengthening of the current piping system.

The Effect of Passing Aged Years to the Polarization Characteristics of Embedded Steel Bar of Mortar Specimen(W/C:0.4) (몰타르 시험편(W/C:0.4) 내부철근의 분극특성에 미치는 재령년수의 영향)

  • Moon, Kyung-Man;Won, Jong-Pil;Park, Dong-Hyun;Lee, Sung-Yul;Jeong, Jin-A;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • The structures of reinforced concrete has been extensively increased with rapid development of industrial society. Futhermore, these reinforced concretes are easy to expose to severe corrosive environments such as sea water, contaminated water, acid rain and seashore etc.. Thus, corrosion problem of inner steel bar embedded in concrete is very important in terms of safety and economical point of view. In this study, multiple mortar test specimen(W/C:0.4) with six types having different cover thickness each other was prepared and was immerged in seawater solution for five years to evaluate the effect of cover thickness and immersion years to corrosion property of embedded steel bar. And the polarization characteristics of these embedded steel bars was investigated using electrochemical methods such as measuring corrosion potential, cathodic polarization curve, and cyclic voltammogram. At the beginning of immersion, the corrosion potentials exhibited increasingly nobler values with increasing cover thickness. However, after immersed for 5 years, the thicker cover of thickness, the corrosion potentials shifted in the negative direction, and the relationship between corrosion potential and cover thickness was not in good agreement with each other. Therefore, it is considered that the thinner cover of thickness, corrosive products deposited on the surface of the embedded steel bar plays the role as a resistance polarization which is resulted in decreasing the corrosion rate as well as shifting the corrosion potential in the positive direction. As a result, it seemed that the evaluation which corrosion possibility of the reinforced steel would be estimated by only measuring the corrosion potential may not be a completely desirable method. Therefore, it is suggested that we should take into account various parameters, including cover thickness, passed aged years as well as corrosion potential for more accurate assessment of corrosion possibility of reinforced steel which is exposed to partially or fully in marine environment for long years.