• 제목/요약/키워드: indoor air ventilation system

검색결과 274건 처리시간 0.028초

한지(韓紙)의 환기성능에 관한 실험적 연구 (The Experimental Study on the Efficiency of Ventilation of Korean Paper (Hanji))

  • 이종원;임정명
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.482-489
    • /
    • 2004
  • The purpose of this study is to reevaluate the performance of Hanji as a architectural material. Recent studies report that one of the causes of the Sick-HouseㆍSick-Building Syndrome is due to the contaminants from interior materials and the lack of ventilation. In this study, the properties of Hanji are investigated. The major focuses of this research are (1) how efficient the Hanji is for ventilation of the house and (2) whether the usage of Hanji brings required ventilation volume to the house. According to the test results, differential pressure in the air and the amount of ventilation showed linear relationship. Test results differ from various kinds of Hanji. Since houses usually have double window system, Hanji can be used to the windows system, especially for inner part of double window system. It is suggested that the combination of Hanji windows for the inner part and glass windows for outer part is very effective, and offers a solution to improvement of indoor air quality and the lack of ventilation with passive ventilation that has less energy consumption.

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구 (A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses)

  • 유형규;박진철;이언구
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.468-476
    • /
    • 2005
  • The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

다기능온돌시스템을 이용한 자연환기성능 평가 (Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System)

  • 조동우;유기형;유정연;정해권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

지하 수처리시설 유지관리층 환기설비의 성능평가 (Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant)

  • 강한기;이재헌
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.

초고층 공동주택의 하이브리드 환기시스템의 성능평가에 관한 연구 (A study on the Performance of Hybrid ventilation system in High-rise Apartment Houses)

  • 김옥;박창봉;박진철;김남규;이언구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.113-118
    • /
    • 2007
  • As the economic living standards are higher, the demands for more comfortable living space are also larger. In the response of this requirements, studies for improving indoor air environment have been conducted. In case of newly-built apartment buildings, the standard for the minimum ventilation to improve their indoor air quality was made. This study analysed the experimental results from the mock-up test of the hybrid ventilation system which is composed of natural and mechanical ventilation.

  • PDF

자연환기와 복사냉방을 병용한 하이브리드 시스템의 제안 (A Proposal of Hybrid Cooling System Coupled with Radiation Panel Cooling and Natural Ventilation)

  • 송두삼
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.543-550
    • /
    • 2003
  • In order to saving the energy for HVAC system of buildings, utilization of wind-induced cross ventilation is thought to be promising. However, utilization of natural ventilation alone is not sufficient for maintaining the human thermal-comfort such as in hot and humid regions. A hybrid air conditioning system with a controlled natural ventilation system, or combination of natural ventilation with mechanical air conditioning is thought to overcome the deficiency of wind-driven cross ventilation and to have significant effects on energy reduction. This paper describes a concept of hybrid system and propose a new type of hybrid system using radiational cooling with wind-induced cross ventilation. Moreover, a radiational cooling system is compared with an all-air cooling system. The characteristics of the indoor environment will be examined through CFD (Computational Fluid Dynamics) simulation, which is coupled with a radiation heat transfer simulation and with HVAC control in which the PMV value for the human model in the center of the room is controlled to attain the target value.

주거용 건물의 개별 환기시스템 필요성에 관한 연구 (The Individual Heat-recovery ventilation system of Residential Buildings)

  • 신우철;이왕제;윤종호;백남춘
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.99-104
    • /
    • 2014
  • Recently supply of low energy house is increasing which can enhance energy efficiency and indoor environment comfort. Low energy house have to secure air tightness as well as thermal performance so house become high airtightness and inevitably need heat recovery ventilator to enhance indoor air quality. However, most of current ventilation systems are one-click, controlling the entire space so it causes increasing of heating load and fan power which makes it hard to save energy. Thus, Individual Control system is required which can achieve both enhancing indoor air quality and decreasing heating load and electric fan power. Thereby, in this study, we analyzed the correlation between ventilation and fan power through mock-up experiment and measured ventilation load under individual control system. As a result, under the condition of $24^{\circ}C$ of indoor temperature for 6 month(November to April) in Daejeon, ventilation load by fan speed was $10.9{\sim}19.6kWh/m^2{\cdot}a$ when operated 24 hours and $7.6{\sim}13.7kWh/m^2{\cdot}a$ when operated 12 hours in night time. In addition, it is possible to reduce at most 60% of ventilation load under the individual control system; measured ventilation load was $7.4kWh/m^2{\cdot}a$ when operated 24 hours, and $5.5kWh/m^2{\cdot}$ when operated 12 hours in night time.

공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구 (A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance)

  • 김승철;윤종호;백남춘;신우철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

변위환기를 이용한 대형 용접작업장의 공기환경 개선에 관한 연구 (Improvement of Indoor Air Environment in a Large Welding Factory by Displacement Ventilation)

  • 조동환;강석윤;최충현;임윤철;이재헌;문정환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.69-74
    • /
    • 2005
  • In this paper, the indoor air environment in a large welding factory applied to displacement ventilation was investigated with experiment and numerical analysis for previous and new ventilation system. Concentration of fumes was analyzed for three cases with wind direction of outdoor. For experimental results, the dust concentration with new ventilation system decreased about 42-60% and the visibility increased about 11-18%. For numerical analysis, the exhaust efficiency of fumes was low when the wind and exhaust flow direction was inverse. It was found that the fumes in the factory decreased about 77% in case of the northern wind.

  • PDF

실측을 통한 신축공동주택의 주요 VOCs 물질 농도에 관한 연구 (A Study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement)

  • 김창남;김용경;이성진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1220-1224
    • /
    • 2008
  • Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SHS(Sick House Syndrome), MCS(Multi Chemical Sensitivity). The purpose of this study is to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as Formaldehyde and VOCs, the field measurement were conducted.

  • PDF