A Study on a Proper Reduction Process of Indoor Air Pollutants In Newly-Constructed Multi-Family Houses

신축공동주택에서의 실내공기 오염물질 방출 저감 프로세스에 관한 연구

  • Yu Hyung-Ku (Graduate School of Architecture, Chung-Ang University) ;
  • Park Jin-Chul (Department of Architecture, Chung-Ang University) ;
  • Rhee Eon-Ku (Department of Architecture, Chung-Ang University)
  • Published : 2005.05.01

Abstract

The purpose of this study is to investigate actual air quality in newly-constructed multi-family houses and to improve Indoor Air Quality (IAQ). The field measurement was conducted in four different newly-constructed multi-family house complexes in Seoul and one existing multi-family house complex in Kyong-gi province. The result of the measurement shows that indoor concentrations of Formaldehyde and TVOC in newly-constructed multi-family houses are much higher than the foreign standards. To establish a proper process for reducing indoor air pollutants, various experiments have been conducted; application of natural materials, bake-out practice, closure of all openings without ventilation, and use of mechanical ventilation system. The result indicates that three practices (natural materials, bakeout, mechanical ventilation) can reduce the level of indoor air pollutants almost in half during the experiments. However, each practice has its limitation and is insufficient to satisfy IAQ standards. Therefore, the study proposes a proper reduction process of indoor air pollutants which combines four different practices in time sequence.

Keywords

References

  1. Rhee, E. K, 2004, A Study on the Proper Reduction Method of Indoor Air Pollutant in Buildings (APT, Officetel), Chung-Ang University, p. 1
  2. Park, J. C., et al., 2004, A measurement of formaldehyde and volatile organic compounds (VOC's) in apartment houses, Journal of Architectural Institute of Korea Proceedings, Vol. 24, No.1, pp.601-604
  3. Kim, Y. S., et al., 1999, Research on the indoor air quality management, Ministry of Environment, p. 10
  4. Kim, S. D., et al., 2002, Research on the indoor air pollution characteristic and management method, Ministry of Environment, p.1
  5. Park, J. C., 2003, A study on the improvement of indoor air quality in residential buildings, Journal of Architectural Institute of Korea, Vol. 19, No.6, pp. 129-137
  6. Indoor Air Quality Testing Method, 2004, Ministry of Environment
  7. Compendium Method TO-17, 1999, Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes
  8. KS M ISO 16000-3, 2003, Determination of formaldehyde and other carbonyl compounds - Active sampling method