• Title/Summary/Keyword: individual dose

Search Result 351, Processing Time 0.023 seconds

Selection of Key Radionuclides for P&T Based on Radiological Impact Assessment for the Deep Geological Disposal of Spent PWR/CANDU/DUPIC Fuels

  • Lee, Dong-Won;Chung, Chang-Hyun;Kim, Chang-Lak;Park, Joo-Wan
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.231-240
    • /
    • 2001
  • When it is assumed that PWR, CANDU and DUPIC spent fuels are disposed of in deep geological repository, consequent annual individual doses are calculated, and it is shown that doses meet the regulatory limit. From these results, the hazardous radionuclides applicable to partitioning and transmutation are selected. These selected radionuclides such as Tc-99, Ⅰ-129, Cs-135 and Np-237 are then reviewed in terms of partitioning and transmutation. Separation of I-129, Np-237 and Tc-99 from spent fuels is considered desirable, and transmutation of these radionuclides results in remarkable hazard reduction. However, it is concluded that separation and transmutation of Cs-135 may be ineffective although it is classified into a hazardous radionuclide.

  • PDF

Variability of Platelet Reactivity on Antiplatelet Therapy in Neurointervention Procedure

  • Yi, Ho Jun;Hwang, Gyojun;Lee, Byoung Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.3-9
    • /
    • 2019
  • As more intracranial aneurysms and other cerebrovascular pathologies are treated with neurointervention procedure, thromboembolic events that frequently lead to serious neurological deficit or fatal outcomes are increasing. In order to prevent the thromboembolic events, antiplatelet therapy is used in most procedures including coil embolization, stenting, and flow diversion. However, because of variable individual pharmacodynamics responses to antiplatelet drugs, especially clopidogrel, it is difficult for clinicians to select the adequate antiplatelet regimen and its optimal dose. This article reviews the neurointervention literature related to antiplatelet therapy and suggests a strategy for tailoring antiplatelet therapy in individual patients undergoing neurointervention based on the results of platelet function testing.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Simulation and design of individual neutron dosimeter and optimization of energy response using an array of semiconductor sensors

  • Noushinmehr, R.;Moussavi zarandi, A.;Hassanzadeh, M.;Payervand, F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.293-302
    • /
    • 2019
  • Many researches have been done to develop and improve the performance of personal (individual) dosimeter response to cover a wide of neutron energy range (from thermal to fast). Depending on the individual category of the dosimeter, the semiconductor sensor has been used to simplify and lightweight. In this plan, it's very important to have a fairly accurate counting of doses rate in different energies. With a general design and single-sensor simulations, all optimal thicknesses have been extracted. The performance of the simulation scheme has been compared with the commercial and laboratory samples in the world. Due to the deviation of all dosimeters with a flat energy response, in this paper, has been used an idea of one semi-conductor sensor to have the flat energy-response in the entire neutron energy range. Finally, by analyzing of the sensors data as arrays for the first time, we have reached a nearly flat and acceptable energy-response. Also a comparison has been made between Lucite-PMMA ($H_5C_5O_2$) and polyethylene-PE ($CH_2$) as a radiator and $B_4C$ has been studied as absorbent. Moreover, in this paper, the effect of gamma dose in the dosimeter has been investigated and shown around the standard has not been exceeded.

Different Sources and Levels of Copper Supplementation on Performance and Nutrient Utilization of Castrated Black Bengal (Capra hircus) Kids Diet

  • Mondal, M.K.;Biswas, P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.7
    • /
    • pp.1067-1075
    • /
    • 2007
  • Twenty eight 3-4 month old castrated Black Bengal kids (Capra hircus) were used to determine the effects of source and level of dietary copper (Cu) concentration on their performance and nutrient utilization. Cu was supplemented (0, 10, 20 and 30 mg/kg diet DM) as copper sulfate ($CuSO_4$, $5H_2O$) or copper proteinate (Cu-P). Kids were fed a basal diet containing maize (19.5%), soybean (17.0%), deoiled rice bran (56.5%), molasses (4.0%), di-calcium phosphate and salt (1.0% each) and mineral and vitamin mixture (0.5% each) supplements at 3.5% of body weight to meet NRC (1981) requirements for protein, energy, macro minerals and micro minerals, excluding Cu. The basal diet contained 5.7 mg Cu/kg, 122.5 mg Fe/kg, 110 mg Zn/kg, 0.26 mg Mo/kg and 0.32% S. $CuSO_4$ or Cu-P was added to the basal diet at the rate of 10, 20 and 30 mg/kg. Kids were housed in a well ventilated shed with facilities for individual feeding in aluminum plated metabolic cages. Blood samples were collected from the jugular vein on d 0, 30, 60 and 90 to determine hemoglobin (Hb), packed cell volume (PCV), total erythrocyte count (TEC), total leukocyte count (TLC) and serum enzymes (alkaline phosphatase, alanine transferase and aspertate transferase). A metabolism trial of 6 days duration was conducted after 90 days of experimental feeding. Statistical analysis revealed that source and level of Cu supplementation improved live weight gain (p<0.04) and average daily gain (p<0.01). No significant contribution of source and level of Cu to alter serum serum enzymes was evident. Goats fed Cu-P tended to have higher Hb, PCV and TEC than with $CuSO_4$ supplementation. Cu-P increased digestibility of ether extract (EE, p<0.02) and crude fiber (p<0.05) and showed an increasing trend (p<0.09) for digested crude protein (CP) and crude fiber (CF). Supplemental dose of Cu linearly improved (p<0.02) digestibilities of dry matter (DM), organic matter (OM), EE and nitrogen free extract (NFE). Though the absorption of nitrogen (N) was not affected (p>0.10) by both source and dose of Cu, N retention was affected (p<0.04) and there was a significant $Source{\times}Dose$ interaction (p<0.05). Final body weight (BW) was not influenced (p>0.10) by the source of Cu but increasing dose of Cu increased (p<0.04) the BW of kids. TDN intake (g/kg $W^{0.75}$) was higher (p<0.05) with the increased dose of Cu and there was a significant $Source{\times}Dose$ interaction. It was concluded that supplementation of Cu from different sources and varying dose level in a concentrate based diet may improve performance, nutrient utilization and plane of nutrition in castrated Black Bengal kids. The effects on performance and nutrient utilization are more pronounced with Cu-P than $CuSO_4$ supplementation. Higher dose of Cu showed better result than lower dose.

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

A Study on the Implementation of Dose Constraints in Occupational Dose According to ICRP 103 Recommendations in Korea (ICRP신권고에 따른 직무피폭에서의 선량제약치 국내 적용 방안 연구)

  • Kim, Yong-Min;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.127-133
    • /
    • 2011
  • In 2007, the International Commission on Radiological Protection (ICRP) published Recommendations of the International Commission on Radiological Protection. Accordingly IAEA safety standards committees have reviewed and revised the BSS. The process of the implementation of the ICRP 103 into Korean radiation protection regulations has been continued. Although the new recommendations retain the fundamental protection principles, the impact of the new ICRP recommendations will necessarily be greater than ever before. ICRP recommends the application of dose constraint in planned situations and reference level in existing & emergency situations for strengthening of the principle of optimization. Dose constraints and reference level play a criterion on the level of individual dose as prospective and source-related values. Therefore it is necessary to apply dose constraints and reference levels to all nuclear and RI&RG facilities in Rep. of Korea. Dose constraints and reference level of occupational exposure will be set-up by the stakeholder itself with the cooperation of regulatory body. In this study, the implementation method was discussed to apply the dose constraints and reference level as the procedure for the optimization, not the tool of the regulation.

Quality Control of Radiation Dosimetry Service (개인피폭선량 측정기관의 품질관리기준 개발)

  • Lee, Jun-Haeng;Lee, Sang-Bock;Chang, Kun-Jo;Lee, Kwang-Yong;Lee, Hyun-Koo;Kim, Hyeog-Ju;Jin, Gye-Hwan
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2009
  • We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11.1993, but currently, in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11.2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance. Criteria for Testing are documents applicable in supervising laboratories.

  • PDF

Analysis of Individual Exposure Dose of Workers and Clinical Practice Students in Radiation Management Area (방사선관리구역내의 종사자 및 임상실습 학생의 개인피폭선량 비교 분석)

  • Lee, Joo-Ah
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.383-388
    • /
    • 2017
  • The purpose of this study was to compare radiation dose among workers in the radiation zone and to compare the doses of students in clinical practice in the same area to provide basic data on optimization of radiation protection. The subjects were 121 radiation related workers, 36 radiation workers, and 121 students who completed 8 weeks of clinical practice from Jan. 2016 to Dec. The depth and surface dose between the radiation related workers and the radiation workers were the highest with $.7440{\pm}1.676mSv$ and $.7753{\pm}1.730mSv$, respectively, and statistically significant (p<.01). Among the three groups, the depth dose was the highest at $.143{\pm}.136mSv$ for clinical practice students and the highest at surface dose of $.1513{\pm}.139mSv$. The lowest in both cases, The mean difference between the two groups was statistically significant (p<.01). In conclusion, it is necessary to manage thoroughly according to the ALARA(As Low As Reasonably Achievable) principle. Especially, it is necessary to systematically manage the dose of radiation for clinical students who are in the blind spot of radiation safety management.

Effective Doses in the Radial Gamma Radiation Field near a Point Source: Gender Difference and Deviation from the Personal Dose Equivalent (점선원 감마선장에서 유효선량의 성별차 및 개연선량당량과의 차이)

  • Chang, Jai-Kwon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.299-307
    • /
    • 1997
  • The individual dose equivalent, $H_p$, effective dose, E, and gender specific effective dose, $E^m$ and E$^f$, were evaluated using the male and female phantoms of MIRD type located in the radial gamma radiation field near a point source. The point sources were placed at the distances of 15, 40 and 100 cm in front of the body at different heights. Two radionuclides, $^{137}Cs$ and $^{131}I$, were selected for the illustrative examples. In terms of the gender specific effective doses, $E^f$ is higher than $E^m$ with a few exceptions, e.g. the case where the point source is at the height of reproductive organs, but the differences from the sex- averaged values are not significant enough to justify use of gender specific dose conversion factors for the radial gamma field. The ratios $H_p$/E were in the range of 1 to 3 depending on the source and dosimeter positions when the dosimeter is worn on the front surface of the torso covering from chest to lower abdomen, but varied from 0.34 to 6.5 in extreme cases. When it is assumed that the typical handling procedure of radioactive source material and the typical dosimeter position(on the chest) be respected, the dosimeters calibrated against the broad parallel field appear to provide estimates with acceptable errors for the effective dose of workers exposed to radial broad gamma field around a point source.

  • PDF