• Title/Summary/Keyword: incandescent

Search Result 184, Processing Time 0.023 seconds

A Study on the Application of LED at Ultra-low Temperature (극저온에서 LED 응용에 관한 연구)

  • Ha, Hee-Ju;Kim, Jin-Wook;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.600-605
    • /
    • 2014
  • The interest in development on luminaires which are available up to $-52^{\circ}C$ is surging as demands in vessels navigating a north pole route increase. A conventional incandescent lamp used in vessels is operated stably at $-52^{\circ}C$, but many countries including Korea have eliminated the use of incandescent lamps gradually because of its low luminous efficacy. In this paper, therefore, to develop the LED luminaires with high-efficiency, long lifetime that enables to substitute for incandescent lamp, it has studied about cryogenic characteristics of LED packages, bulbs, driving circuit and power supply. This experiments were carried out according to standards IEC 60945-8.4.1. Temperature range is from $-60^{\circ}C$ to $25^{\circ}C$, and the light output depending on ambient temperature. It showed that, based on $25^{\circ}C$, light output of a CFL decreased by 80% of CFL at $-20^{\circ}C$ while each increased 12% of LED bulbs and 16~19% of LED packages at $-60^{\circ}C$.

A Study on the Leading Effect of Fish Attracting Lamps on Fish Schools into a Set-net - The Leading Effect of Incandescent Electric Light on Fish Schools - (집어등에 의한 정치망에의 어군유도에 관한 연구 I . 백열등에 의한 어군의 유도효과)

  • Park, Jeong-Sik;Kim, Seok-Jong;Kim, Mun-Gwan
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.311-320
    • /
    • 1997
  • We selected horse mackerel Trachurus japonicus, mackerel Scomber japonicus and arrow squid Todarodes pacificus, to be used in the experiment. These fishes migrate to the Cheju coast and were caught by set-net. We studied on the attracting effect and the leading effect on the fish school using incandescent lights in an outdoor water tank at the Marine Research Institute Cheju National University. The results obtained are summarized as follows; 1. The horse mackerels, mackerels and arrow squids were actively attracted to the incandescent light. The optimum illumination and the reactions of each fish school were different though. 2. We turned the first attracting lamp on and turned it off after ten minutes. Then we turned the second attracting lamp on and turned it off after another ten minutes. The reaction of each fish school was a little bit different, but it worked to lead them to their destination. 3. We turned the three attracting lamps on at the same tune. After ten minutes, We turned the first attracting lamp off. After another ten minutes we turned the second attracting lamp off. The reaction of each fish school was a bit different, but it worked to lead them to their destination. 4. One incandescent light was moving. The reaction of each fish school was a little bit different, but it worked to lead them to their destination.

  • PDF

A Study on the emergency and repairing AC/DC combination lamp (AC/DC 겸용 비상 및 복구등에 관한 연구)

  • An, Youn-Ki;Choi, Hong-Kyoo;Choi, June-Young;Lee, Jung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.19-25
    • /
    • 2009
  • The Study is for improvement of power plant equipment environment. Emergency lamp already installed In transformer substations has weak Illuminance. Because emergency battery is limited and incandescent electric lamps installed has low intensity of illumination and bad efficiency. It is too dark to operate many types of equipment in work Therefore this paper proposes that we use fluorescent lamp instead of incandescent electric lamp and change the old illumination standard for evident standard from the can coup with accident rapidly.

  • PDF

A Case Study on the Lights Fire(Focus on the Electric Bulbs and Fluorescent Lamps) (조명등 화재사례 연구(전구 및 형광등 중심으로))

  • Song, T.H.;Lee, E.P.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.41-58
    • /
    • 2008
  • The history of illumination has been much long since the discovery of lamplight caused huge changes in human lives. However, the swift development of the illumination actually started with the invention of a carbon filament lamp by Thomas Edison in 1878. Generally, the illumination tools plays important roles in human lives such as reduction of fatigue, improvement of safety and working efficiency, and the creation of enjoyable atmosphere. But, the illumination tools can be an origin of the fire due to carelessness and lack of management. In this study, the principle and structure of the illumination lamp were dealt with. The possibility of the fire outbreak caused by the incandescent lamp and fluorescent lamp most used in home was investigated. The examples of the fire outbreaks by the incandescent and fluorescent lamps and by the contact between the inflammable materials and the distributing wires were mentioned and demonstrated by the experimental.

  • PDF

A Study on the Thermal and Optical Properties of a LED Chamber Light for Vessels (선박용 LED Chamber Light의 열 및 광학 특성에 관한 연구)

  • Kim, Sang-Hyun;Lee, Do-Yup;Kim, Woo-Sung;Jang, Nakwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • Recently, LED is widely used in the kinds of display devices or lighting. In this paper, we fabricated LED chamber light for naval vessels to replace to conventional chamber light using incandescent lamp. The LED package of chamber light was designed with luminous intensity of 5.5 cd, color temperature of $6,000{\pm}500K$, forward voltage of 3~3.2 V and input current of 60 mA. A LED module was composed of 36 LED packages and metal PCB. The VF and luminous intensity of LED package were getting down when temperature increased. The temperature of LED chamber light was measured by changing the number of LED package and applied current for one hour when an electric current flow. The heat transfer capability have been improved by using metal PCB. The power consumption of LED chamber light reduced by 86% compared to the conventional chamber light using incandescent lamp.

The Performance of generated Heating Energy from Interior Lighting Fixtures (실내조명의 발열량 예측에 관한 실험 연구)

  • Choi, Jong-seon;Lim, Hong-Soo;Kim, Kyung-Ah;Lee, Keum-hwan;Koo, Jae-Oh;Kim, Gon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

A Study on the Series Arc Detection in Low-voltage Wiring Systems (저압배선계통에서 직렬아크의 검출에 관한 연구)

  • Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Park, Chan-Yong;Kim, Hwang-Kuk;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

Evaluation of illuminant effect of NIR(Near Infrared Radiation) using spectrophotometer for medicine (의학용 분광광도계를 이용한 근적외선 대역의 조명 영향평가)

  • Lee, Sangsik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.4
    • /
    • pp.16-22
    • /
    • 2010
  • In this paper, we evaluated the effect with respect to the light of 700-1,100 nm NIR(near infrared radiation) for spectrophotometer. Standard, red, yellow, green and blue color paper which was Munsell color paper were used for experiments. Our used light is incandescent lamp, fluorescent lamp, invert fluorescent lamp and combined lamp. Each color paper was measured 20 times. Therefore we concluded that it is possible to build a spectrophotometer for NIR(near infrared radiation) measurement we applied an spectrophotometer to measurement system in incandescent lamp.

  • PDF

A Basic Study on Improvement of PLS as a future Lighting by Prospect of Global Demands and Analysing Lighting Technology (Global 조명수요 전망 및 조명 기술 분석을 통한 미래 조명용 PLS 발전 방향 모색)

  • Oh, Eun-Suk;Jung, Kwan-Jin;Jung, Im-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.168-171
    • /
    • 2006
  • After an incandescent lamp developed as a first light source using electric energy in 1879, various lamps have been developed and promoted for usual convenience. Although lots of light sources have been developed for the past centry, among them some were used widely but some were hardly used contray to the initial expectations. Incandescent, fluorescent, HID and LED lamps which are normally used these days were treated as new type of light sources and very difficult to be popularized at the initial stage. In spite of the initial difficulties, these light sources and luminaries are still so popular because all of them were improved to be used easily by reflecting human's mental and physiological state. Like this when new light sources and luminaries are developed, a careful consideration, if these are proper for the surroundings or not, must be preceded. This study finally derived development factors of PLS developed in domestic to be played an important role in future light by analyzing product trends, social and lighting development changes.

  • PDF

Breakdown Characteristics of Ar/N2 and Kr/N2Gas Mixtures with Pressure Variation (압력변화에 따른 Ar/N2및 Kr/N2혼합가스의 절연파괴 특성)

  • 이상우;이동인;이광식;김인식;김이국;배영호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.1
    • /
    • pp.106-113
    • /
    • 2002
  • In this paper, breakdown characteristics of pure Kr, Ar and $N_2$gas with gas pressure range were investigated, and the measured values were compared with those in Ar/$N_2$and Kr/$N_2$gas mixtures with pressure varying. Also, various characteristics with gas mixtures in practical incandescent lamps were investigated. Summarizing the experimental results, the breakdown voltages of $N_2$gas were increased than those of Kr and Ar gas with large molecular weight, and the breakdown voltage increased with gas pressure increasing. The breakdown voltages of Ar/$N_2$and Ar/$N_2$gas mixtures were decreased with decreasing the mixtures ratio of $N_2$gas, and corona inception voltage of Kr/$N_2$gas mixtures under non-uniform fields were increased than those of Ar/$N_2$gas mixtures. In case of tactical incandescent lamps, luminous and lifetime of Kr(70%)/$N_2$(30%) gas mixtures were increased about 94[lm] and 380[hr] than those of Ar(70%)/$N_2$(30%) gas mixtures. and injection pressure of gas mixtures with cooling temperature of 20[$^{\circ}C$] in incandescent lamps were increased about 13[%] than those with cooling temperature of 40[$^{\circ}C$].