• Title/Summary/Keyword: in-situ Calibration

Search Result 110, Processing Time 0.031 seconds

Streaming potential and groundwater contamination

  • Baker Simon S.;Cull James P.
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 2004
  • Measurements of streaming potential can provide a means for the detection and quantification of contaminants in groundwater prior to remediation. However, laboratory determinations of specific electrolyte properties are required for an adequate analysis of the hydraulic gradient in complex situations. Data obtained for the King River in Tasmania confirm a linear relationship linking streaming potential data and hydraulic gradients. Laboratory samples at low concentration (0.001M KCl) indicate values in the range 20-80 mV/cm of water pressure, while for higher concentrations (0.01M KCl) values are less than 25 mV/cm. Similar ion concentrations are observed in the King River, consistent with field correlations indicating values for streaming potential close to 15 mV/cm. In-situ fluid samples are required for more detailed analysis of local anomalies that may be associated with variations in recharge and migration of contaminants.

A Study on the Soil Deformation Due to a Pile Penetration in Sandy Soils. (사질토 지반에서의 말뚝관입으로 인한 흙의 변형에 관한 연구)

  • 백세환;이장덕
    • Geotechnical Engineering
    • /
    • v.6 no.3
    • /
    • pp.31-40
    • /
    • 1990
  • The soil deformation due to a pile penetration in sandy soils has been analysed in model pile penetration tests. To simulate the actual ground conditions, especially the in-situ stress levee the tests were performed in a calibration chamber where both the vertical and the horizontal stresses could be applied separately. The deformation was monitored via 5 earth pressure cells. The results, were compared with the theortical values based on the theory of cavity expansion.

  • PDF

Airborne Hyperspectral Imagery availability to estimate inland water quality parameter (수질 매개변수 추정에 있어서 항공 초분광영상의 가용성 고찰)

  • Kim, Tae-Woo;Shin, Han-Sup;Suh, Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.61-73
    • /
    • 2014
  • This study reviewed an application of water quality estimation using an Airborne Hyperspectral Imagery (A-HSI) and tested a part of Han River water quality (especially suspended solid) estimation with available in-situ data. The estimation of water quality was processed two methods. One is using observation data as downwelling radiance to water surface and as scattering and reflectance into water body. Other is linear regression analysis with water quality in-situ measurement and upwelling data as at-sensor radiance (or reflectance). Both methods drive meaningful results of RS estimation. However it has more effects on the auxiliary dataset as water quality in-situ measurement and water body scattering measurement. The test processed a part of Han River located Paldang-dam downstream. We applied linear regression analysis with AISA eagle hyperspectral sensor data and water quality measurement in-situ data. The result of linear regression for a meaningful band combination shows $-24.847+0.013L_{560}$ as 560 nm in radiance (L) with 0.985 R-square. To comparison with Multispectral Imagery (MSI) case, we make simulated Landsat TM by spectral resampling. The regression using MSI shows -55.932 + 33.881 (TM1/TM3) as radiance with 0.968 R-square. Suspended Solid (SS) concentration was about 3.75 mg/l at in-situ data and estimated SS concentration by A-HIS was about 3.65 mg/l, and about 5.85mg/l with MSI with same location. It shows overestimation trends case of estimating using MSI. In order to upgrade value for practical use and to estimate more precisely, it needs that minimizing sun glint effect into whole image, constructing elaborate flight plan considering solar altitude angle, and making good pre-processing and calibration system. We found some limitations and restrictions such as precise atmospheric correction, sample count of water quality measurement, retrieve spectral bands into A-HSI, adequate linear regression model selection, and quantitative calibration/validation method through the literature review and test adopted general methods.

Method for Measuring Mechanical Behaviors of Thin Films at High Temperature (고온에서 박막의 기계적 거동 측정 방법)

  • Lim, Sang-Chai;Joo, Jae-Hwang;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.102-108
    • /
    • 2003
  • Recently, the authors have developed a new material test system fur thin film at the high temperature. It is so compact and precise with sub micron resolution that it seems to be a useful tool fur research of the oxide film growth, its mechanical behavior and failure mechanism. To this end. in this paper three methologies are described for in-situ monitoring of the displacement & strain and the temperature, the oxide thickness. These are the Laser Speckle analysis with digital image correlation technique, the two-color infra-red thermometer and the laser reflection interferometry respectively. The calibration results and some issues which should be addressed for practical application are presented.

Estimation of Deformation Modulus of Cemented Sand using CPT and DMT (CPT와 DMT를 이용한 고결모래의 변형계수 추정)

  • Lee, Moon-Joo;Choi, Sung-Kun;Hong, Sung-Jin;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.484-491
    • /
    • 2008
  • The purpose of this study is to compare the cementation effect on cone resistance and DMT indices and to evaluate the deformation characteristic of cemented sand using cone resistance and dilatometer modulus. Specimens of various relative densities with three different cementation levels are prepared in a large calibration chamber under different vertical stress levels. Test result shows that the cone resistance and dilatometer modulus underestimate the deformation modulus of cemented sand, since in situ penetration tests such as CPT and DMT damage the cementation bonds during penetration. By regression analysis, the constrained modulus of cemented sand is related with the cone resistance and the dilatometer modulus.

  • PDF

Application of Laser-Induced Breakdown Spectroscopy (LIBS) for In-situ Detection of Heavy Metals in Soil (토양내 중금속 실시간 탐지를 위한 레이저 유도붕괴 분광법의 활용에 대한 소개)

  • Ko, Eun-Joung;Hamm, Se-Yeong;Kim, Kyoung-Woong
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.563-574
    • /
    • 2007
  • Laser induced breakdown spectroscopy (LIBS) is a recently developed analytical technique that is based upon the measurement of emission lines generated by atomic species close to the surface of the sample, thus allowing their chemical detection, identification and quantification. With powerful advantages of LIBS compared to the conventional analytical methodology, this technique can be applied in the detection of heavy metals in the field. LIBS allows the rapid analysis by avoiding laborious chemical steps. LES have already been applied for the determination of element concentration in a wide range of materials in the solid, liquid and gaseous phase with simplicity of the instrument and diversity of the analytical application. These feasibility of rapid multi elemental analysis are appealing proprieties for the in-situ analytical technique in geochemical investigation, exploration and environmental analysis. There remain still some limitations to be solved for LIBS to be applied in soil environment as an in-situ analytical technology. We would like to provide the basic principle related to the plasma formation and laser-induced breakdown of sample materials. In addition, the matrix effect, laser properties and the various factors affecting on the analytical signal of LIBS was dealt with to enhance understanding of LIBS through literature review. Ultimately, it was investigated the feasibility of LIBS application in soil environment monitoring by considering the basic idea to enhance the data quality of LIBS including the calibration method for the various effects on the analytical signal of LIBS.

The preliminary evaluation of semi-quantitative analysis by in situ pre-chromatographic derivatization of amines and image analysis in TLC (TLC상 분리 전 직접적 유도체화 반응과 이미지 분석을 통한 아민 화합물의 반정량분석을 위한 선행평가)

  • Kim, Younsu;Choi, Sung-Woon
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.79-85
    • /
    • 2015
  • A preliminary experiment was performed to develop a fast, convenient, and economical semi-quantitative method of analyzing amphetamine-like amines from images of derivatives. These were generated from the reaction (in situ, co-spot) of three amphetamine-like compounds with three derivatization reagents on a TLC plate. The attempt was made to optimize the reaction conditions for an efficient derivatization reaction, and TLC images taken by a digital camera were analyzed using two types of image analysis program (CP Atlas 2.0 and ImageJ) for repeatability (RSD, %) and linearity (R2). Then, their results were compared. For efficient derivatization, the reaction conditions needed to be modified. The results of image analysis of each of the samples at two different concentrations (0.5 mg/mL and 0.01 mg/mL) showed that the RSD values for reaction repeatability were in the range of 0.69-5.50%. From the calibration curves between the area of the derivative and the concentration of amines, the R2 values (R2 > 0.9906) for good linear correlation were found to be high, in a concentration range of 0.1-0.005 mg/mL of amines. In addition, the two programs demonstrated little difference in the analysis of repeatability and linearity of the derivatization, so that the current method has the potential to be used for the semi-quantitative analysis of amines.

In situ Measurement of Lateral Side-Necking of a Fracture Specimen Using a Stereo Vision and Digital Image Correlation (Stereo Vision과 디지털 화상상관법을 이용한 파괴시험편의 측면 함몰의 현장 측정)

  • Lee Jeong-Hyun;Kang Ki-Ju
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.154-161
    • /
    • 2004
  • An experimental method for measuring side-necking deformation near a crack-tip is described. It is based on Stereoscopic Digital Speckle Photography and Digital Image Correlation, and it is simple and robust to mechanical vibration inherent to a hydraulic material test system. The validity and accuracy are evaluated through a calibration fur rigid body translation. A case study has been performed for a CT specimen made of a ductile steel and the three dimensional profiles of the side-necked region are presented as the load increases. Also, the details of the procedure and the surface treatment are discussed.

Development of Pressuremeter for Evaluation of Deformation Characteristic at Whole Strain Ranges (전체변형률 범위에서 변형특성 평가를 위한 공내재하시험 장치 개발)

  • 권기철
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.335-342
    • /
    • 2003
  • In order to analyze the deformational behavior accurately, the in-situ testing technique which provides the reliable deformational characteristics at whole strain ranges, needs to be developed. The pressuremeter is a unique method for assessing directly the in-situ shear modulus of soils with strain amplitude. This paper introduces a new alternative, the cavity strain measuring system in pressuremeter designed for whole strain ranges of $10^{-5}$%∼20%. Not only in the synthetic calibration chamber but also in the field, the pressuremeter tests were performed to determine the compliance of the new developed pressuremeter system. The variation in shear modulus with strain amplitude above $5\times 10^{-2}$% was reliably determined by the developed pressuremeter. It is concluded that the major cause of error in small cavity strain measuring is not from the cavity strain measuring system but from the friction between measuring arm and membrane during unloading-reloading loops.

Simulating Ammonia Volatilization from Applications of Different Urea Applied in Rice Field by WNMM

  • Park, Ki-Do;Lee, Dong-Wook;Li, Yong;Chen, Deli;Park, Chang-Young;Lee, Young-Han;Lee, Chang-Hoon;Kang, Ui-Gum;Park, Sung-Tae;Cho, Young-Son
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.1
    • /
    • pp.8-14
    • /
    • 2008
  • Ammonia ($NH_3$) volatilization from a silty clay loam paddy soil applied with non, straight urea, and coated urea, respectively, under transplanting in Milyang, Korea from 2002 and 2003 was simulated by a Water and Nitrogen Management Model (WNMM). Based on the data from the in-situ measurements, $NH_3$ volatilization during the rice growth was 6.04% and 1.46% of the applied nitrogen (N) from straight urea and coated urea, respectively. The bulk aerodynamic approach in WNMM satisfactorily predicted the difference in $NH_3$ loss during the given rice growing seasons from the two urea fertilizers. $R^2$ for the correlation between the predicted and observed NH3 loss during the calibration year (2002) was 0.53 less than 0.68 of the application year (2003). This difference could be due to the weather condition such as heavy rainfall and temperature during the calibration year.