• Title/Summary/Keyword: in-process measurement

Search Result 4,836, Processing Time 0.033 seconds

A 12Bit 80MHz CMOS D/A Converter with active load inverter switch driver (능동부하 스위치 구동 회로를 이용한 12비트 80MHz CMOS D/A 변환기 설계)

  • Nam, Tae-Kyu;Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Kim, Soo-Jae;Lee, Sang-Min;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.38-44
    • /
    • 2007
  • This paper describes a 12 bit 80MHz CMOS D/A converter for wireless transceiver. Proposed circuit in the paper employes segmented structure which consists of four stage 3bit thermometer decoders. Proposed D/A converter is manufactured 0.35um CMOS n-well digital standard process and measurement results show a ${\pm}1.36SB/{\pm}0.62LSB$ of INL/DNL and $46pV{\cdot}s$ of glitch energy. SNR and SFDR are measured to be 58.5dB and 64.97dB @ Fs=80MHz and Fin=19MHz with a total power consumption of 99mW. Such results proved that our work has low power consumption, high linearity, low glitch and improved dynamic performance. Therefore, our work can be appled to various high speed and high performance circuits.

An Index for Measuring the Degree of Completeness of BIM-based Quantity Take-Off (BIM기반 물량산출 완성도 측정을 위한 지수 개발)

  • Lee, Chang-Hee;Kim, Seong-Ah;Chin, Sang-Yoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.79-92
    • /
    • 2011
  • Quantity take-off is one of the critical tasks that determine the cost of a construction project, and its result should be accurate and reliable. BIM-based quantity take-off is a very attractive process for practitioners since the quantity take-off can be done automatically in a fast and accurate way. However, the result of BIM-based quantity take-off can be varied depending on how BIM was modeled. As a project progresses, more detailed design information is getting available, and it can be expected that the degree of completeness and accuracy for the BIMbased quantity take-off is going to be improved as well. However, when estimation is performed at each stage of a project life-cycle, there is no way to measure or forecast how accurate of the quantity take-off result from the BIM data given at the current stage. Therefore, this research derived factors that affect the BIM-based quantity takeoff and developed a methodology and framework to measure and forecast the completeness of BIM-based quantity take-off. The measurement framework and index that are proposed by this research was verified and validated for their consistency and feasibility through six pilot projects.

Platelet Rich Plasma Injection: Evidence Based Analysis (혈소판 풍부 혈장 주사 요법: 근거 중심의 분석)

  • Oh, Joo Han;Chung, Seok Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.111-122
    • /
    • 2011
  • Platelet rich plasma (PRP) has been widely used nowadays for several common orthopaedic-related sports medicine conditions with the theoretical basis that PRP supplies numerous autologous growth factors from concentrated platelets needed to promote the healing process of injured tissue. Even though there are many basic sciences, animal studies and some clinical studies regarding PRP injections for musculoskeletal injuries which suggested good results, it is difficult to compare these various studies due to marked methodological differences such as PRP preparation method, the timing, volume and number of injection, and the outcome measurement tool. In addition, many studies have no control groups or a limited sample size, and there are few prospective randomized controlled trials assessing the efficacy of PRP injections. Therefore, well designed high-quality randomized studies are required to confirm the preliminary results until now and provide scientific evidence to support its use, and the paucity of scientific clinical evidence suggest that the administration of PRP on humans for musculoskeletal injuries should be performed with caution.

  • PDF

Kinetic Measurement of the Step Size of DNA Unwinding by Bacteriophage T7 DNA Helicase gp4 (T7 박테리오파지 gp4 DNA helicase에 의한 DNA unwinding에서 step size의 반응속도론적 측정)

  • Kim, Dong-Eun
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.131-140
    • /
    • 2004
  • T7 bacteriophage gp4 is the replicative DNA helicase that unwinds double-stranded DNA by utilizing dTTP hydrolysis energy. The quaternary structure of the active form of T7 helicase is a hexameric ring with a central channel. Single-stranded DNA passes through the central channel of the hexameric ring as the helicase translocates $5'\rightarrow3'$ along the single-stranded DNA. The DNA unwinding was measured by rapid kinetic methods and showed a lag before the single-stranded DNA started to accumulate exponentially. This behavior was analyzed by a kinetic stepping model for the unwinding process. The observed lag phase increased as predicted by the model with increasing double-stranded DNA length. Trap DNA added in the reaction had no effect on the amplitudes of double-stranded DNA unwound, indicating that the $\tau7$ helicase is a highly processive helicase. Global fitting of the kinetic data to the stepping model provided a kinetic step size of 10-11 bp/step with a rate of $3.7 s^{-1}$ per step. Both the mechanism of DNA unwinding and dTTP hydrolysis and the coupling between the two are unaffected by temperature from $4∼37^{\circ}C$. Thus, the kinetic stepping for dsDNA unwinding is an inherent property of tile replicative DNA helicase.

Performance Evaluation of the Serially Connected Two Stage Fiber Filter for the RO Membrane Pre-treatment (2단 섬유여과 공정의 역삼투막 전처리 성능평가)

  • Bae, Si-Youl;Yun, Chang-Han;Kang, Dong-Hyo
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • This study was for the evaluation of adaptability of the fiber filter as the pre-treatment of the RO membrane through SDI (Silt Density Index) measurement. The turbidity of raw waters were $0.76{\sim}1.6$ NTU for the effluent of sewer treatment plants (STP) and $2.2{\sim}3.3$ NTU for sea waters and 100 NTU for the surface water. The turbidity of the $2^{nd}$ filtrate of the serially connected two fiber filters was $0.07{\sim}0.25$ NTU and $SDI_{15}$ was $1.4{\sim}2.8$ when the 17% PAC was dosed $10{\sim}30ppm$. Results of the turbidity and $SDI_{15}$ of the $2^{nd}$ filtrate of the fiber filter which were compared with them of the lab scale MF/UF disc filter for the same STP's effluents showed that filtrate quality were enhanced with a little on the order of two stage fiber filter>MF>UF, the difference in $SDI_{15}$ was only $0.7{\sim}1.0$. So, the filtrate of the serially connected two stage fiber filter could satisfy $SDI_{15}$ 5.0 safely which was normally required for the feed water by the RO membrane supplier and it means the serially connected two stage fiber filter could be applied as the pre-treatment process of the RO membrane.

Influence of Precursor on the Electrochemical Properties of Li(Ni0.5Co0.2Mn0.3)O2 Cathode for the Lithium Secondary Battery (전구체의 물성에 따른 리튬 2차전지용 Li(Ni0.5Co0.2Mn0.3)O2의 전기화학적 특성 변화)

  • Kang, Donghyun;Arailym, Nurpeissova;Chae, Jeong Eun;Kim, Sung-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.4
    • /
    • pp.191-197
    • /
    • 2013
  • The one of the cathode material, $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$, was synthesized by the precursor, $Ni_{0.5}Co_{0.2}Mn_{0.3}(OH)_2$, from the co-precipitation method and the morphologies of the primary particle of precursors were flake and needle-shape by controlling the precipitation parameters. Identical powder properties, such as particle size, tap density, chemical composition, were obtained by same process of lithiation and heat-treatment. The relation between electrochemical performances of $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$ and the primary particle morphology of precursors was analyzed by SEM, XRD and EELS. In the $Li(Ni_{0.5}Co_{0.2}Mn_{0.3})O_2$ cathode from the needle-shape precursor, the primary particle size was smaller than that from flake-shape precursor and high Li concentration at grain edge comparing grain center. The cycle and rate performances of the cathode from needle-shape precursor shows superior to those from flake-shape precursor, which might be attributed to low charge-transfer resistance by impedance measurement.

Thermal Performance of a Heating Board with a Microencapsulated Myristic Acid (Myristic acid를 사용한 축열장판의 열성능 연구)

  • Kwak, H.Y.;Kang, Y.H.;Jeon, M.S.;Lee, T.K.;Lee, D.G.;Han, G.Y.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.177-183
    • /
    • 1998
  • The thermal performance of a heating board with microencapsualted PCM was investigated and compared to conventional heating board. The employed PCM was the myristic acid $$ and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $1{\sim}1.5mm$. Accoring to ANSI/ASHRAE test procedure, the close-loop test configuration was installed. Air was used as the heat transfer fluid and a calibrated orifice was employed for the measurement of air flow rates. The thermal performance test of two different heating boards(with 10 wt% PCM and without PCM) was conducted for different air flow rates and the heat transfer characteristics during cooling was compared. The test results showed that the surface temperature of heating board with 10 wt% PCM maintained higher during the cooling process than that of the heating board without PCM and experimentally determined heat transfer coefficient in heating board with PCM showed higher value compared to heating board without PCM.

  • PDF

A Study of Arrow Performance using Artificial Neural Network (Artificial Neural Network를 이용한 화살 성능에 대한 연구)

  • Jeong, Yeongsang;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.5
    • /
    • pp.548-553
    • /
    • 2014
  • In order to evaluate the performance of arrow that manufactures through production process, it is used that personal experiences such as hunters who have been using bow and arrow for a long time, technicians who produces leisure and sports equipment, and experts related with this industries. Also, the intensity of arrow's impact point which obtains from repeated shooting experiments is an important indicator for evaluating the performance of arrow. There are some ongoing researches for evaluating performance of arrow using intensity of the arrow's impact point and the arrow's flying image that obtained from high-speed camera. However, the research that deals with mutual relation between distribution of the arrow's impact point and characteristics of the arrow (length, weight, spine, overlap, straightness) is not enough. Therefore, this paper suggests both the system that could describes the distribution of the arrow's impact point into numerical representation and the correlation model between characteristics of arrow and impact points. The inputs of the model are characteristics of arrow (spine, straightness). And the output is MAD (mean absolute distance) of triangular shaped coordinates that could be obtained from 3 times repeated shooting by changing knock degree 120. The input-output data is collected for learning the correlation model, and ANN (artificial neural network) is used for implementing the model.

Chip-level NFP Calibration and Verification Using Improved Probe for NFS Standardization (NFS 표준을 위한 개선된 프로브를 이용한 칩 수준 NFP 측정값 교정 및 검증)

  • Lee, Pil-Soo;Wee, Jae-Kyung;Kim, Boo-Gyoun;Choi, Jai-Hoon;Yeo, Soon-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.25-34
    • /
    • 2012
  • New calibration method for the near-field scanning (NFS) system is presented. The proposed calibration method consisted of a new near-field antenna (NFP) and newly devised patterns as circular patch patterns (CPPs) and meander patterns (MPs). The proposed patterns were used for improving spatial resolutions and simplifying a calibration procedure of the NFP compared to the conventional method defined in the IEC61967-3 and 6. Also, the effect of the length of NFPs on attenuation characteristics was investigated with length of 8mm and 30mm. For them, we designed and fabricated CPPs of diameter (D) = 20, 40, 60, and 100mm and MPs of various widths and spaces. We found the reverse relations between spatial resolutions and heights of measuring points by using simplified calibration procedure. The testing result shows that the spatial resolution of $120{\mu}m$ at height of $200{\mu}m$ was verified without complex correlation algorithms under 8GHz. For manufacturing cost all patterns and the NFP were realized with low-cost fabrication using PCB (FR-4) not by a conventional LTCC process. For verification of chip-level EMC from the results, near-field scanning system (NFSS) having step resolution of Sub-micron scale was produced and by using the proposed NFSS and proposed NFP measurement of chip shows accurately the shape of the resolution of $200{\mu}m$ patterns for securing a high level of chip-level EMC verification.

Post-Linearization Technique of CMOS Cascode Low Noise Amplifier Using Dual Common Gate FETs (두 개의 공통 게이트 FET를 이용한 캐스코드형 CMOS 저잡음 증폭기의 후치 선형화 기법)

  • Huang, Guo-Chi;Kim, Tae-Sung;Kim, Seong-Kyun;Kim, Byung-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.41-46
    • /
    • 2007
  • A novel post-linearization technique is proposed for CMOS cascode low noise amplifier (LNA). The technique uses dual common gate FETs one of which delivers the linear currents to a load and the other one sinks the $3^{rd}$ order intermodulation currents of output currents from the common source FET. Selective current branching can be implemented in $0.18{\mu}m$ CMOS process by using a thick oxide FET as an IM3 sinker with a normal FET as a linear current buffer. A differential LNA adopting this technique is designed at 2.14GHz. The measurement results show 11dBm IIP3, 15.5dB power gain and 2.85dB noise figure consuming 12.4mA from 1.8V power supply. Compared with the LNA with turning off the IM3 sinker, the proposed technique improves the IIP3 by 7.5 dB.