• Title/Summary/Keyword: in-position

Search Result 26,502, Processing Time 0.045 seconds

Comparison of error characteristics of final consonant at word-medial position between children with functional articulation disorder and normal children (기능적 조음장애아동과 일반아동의 어중자음 연쇄조건에서 나타나는 어중종성 오류 특성 비교)

  • Lee, Ran;Lee, Eunju
    • Phonetics and Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 2015
  • This study investigated final consonant error characteristics at word-medial position in children with functional articulation disorder. Data was collected from 11 children with functional articulation and 11 normal children, ages 4 to 5. The speech samples were collected from a naming test. Seventy-five words with every possible bi-consonants matrix at the word-medial position were used. The results of this study were as follows : First, percentage of correct word-medial final consonants of functional articulation disorder was lower than normal children. Second, there were significant differences between two groups in omission, substitution and assimilation error. Children with functional articulation disorder showed a high frequency of omission and regressive assimilation error, especially alveolarization in regressive assimilation error most. However, normal children showed a high frequency of regressive assimilation error, especially bilabialization in regressive assimilation error most. Finally, the results of error analysis according to articulation manner, articulation place and phonation type of consonants of initial consonant at word-medial, both functional articulation disorder and normal children showed a high error rate in stop sound-stop sound condition. The error rate of final consonant at word-medial position was high when initial consonant at word-medial position was alveolar sound and alveopalatal sound. Futhermore, when initial sounds were fortis and aspirated sounds, more errors occurred than linis sound was initial sound. The results of this study provided practical error characteristics of final consonant at word-medial position in children with speech sound disorder.

Design of Optimized Fuzzy Cascade Controller Based on HFCGA for Ball & Beam System (볼빔 시스템에 대한 계층적 공정 경쟁 유전자 알고리즘을 이용한 최적 퍼지 Cascade 제어기 설계)

  • Jang, Han-Jong;Oh, Sung-Kwun;Kim, Hyun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.391-398
    • /
    • 2009
  • In this study, we introduce the design methodology of an optimized fuzzy cascade controller with the aid of hierarchical fair competition-based genetic algorithm(HFCGA) for ball & beam system. The ball & beam system consists of servo motor, beam and ball, and remains mutually connected in line in itself. The ball & beam system determines the position of ball through the control of a servo motor. The displacement change the position of ball leads to the change of the angle of the beam which determines the position angle of a servo motor. Consequently the displacement change of the position of the moving ball and its ensuing change of the angle of the beam results in the change of the position angle of a servo motor. We introduce the fuzzy cascade controller scheme which consists of the outer(1st) controller and the inner(2nd) controller as two cascaded fuzzy controllers, and auto-tune the control parameters(scaling factors) of each fuzzy controller using HFCGA. The inner controller controls the position of lever arm which corresponds to the position angle of a servo motor and the outer controller decides the set-point value of the inner controller. HFCGA is a kind of parallel genetic algorithms(PGAs), and helps alleviate the premature convergence being generated in conventional genetic algorithms (GAs). For a detailed comparative analysis from the viewpoint of the performance results and the design methodology, the proposed method for the ball & beam system which is realized by the fuzzy cascade controller based on HFCGA, is presented in comparison with the conventional PD cascade controller based on serial genetic algorithms.

Comparison of the Joint Position Sense at Knee Joint According to Surface Conditions (지지 면 조건에 따른 무릎관절의 관절 위치 재현능력 비교)

  • Hong, Young-Ju;Weon, Jong-Hyuck;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.90-96
    • /
    • 2007
  • The purpose of this study was to compare the joint position sense at the knee joint at 3 different surface conditions by using the active knee joint angle reproduction test in the standing position. Twenty healthy volunteers (10 males and 10 females) age 20~29 years were recruited for this study. The knee joint position senses were assessed at three different surface conditions: on the floor (stable condition), TOGU (soft condition), and seat fit (unstable condition) in a closed kinetic chain. Testing orders were selected randomly. The absolute angle error was defined as the absolute difference between target angles ($30^{\circ}{\sim}45^{\circ}$ knee flexion) and subject perceived angle of the knee flexion. One way ANOVA was used to compare the absolute angle of error among 3 different conditions. The Independent t-test was used to compare the absolute angle of error between male and female. The error angles were significantly different among surface conditions ($1.3^{\circ}{\pm}1.2^{\circ}$ for the floor, $2.1^{\circ}{\pm}0.9^{\circ}$ for the TOGU, and $4.4^{\circ}{\pm}1.8^{\circ}$ for the seat fit, p<.05). There was no significant difference in error angle between male and female. In conclusion, the joint position sense of the knee joint in the closed kinetic chain decreased at unstable surface conditions. The result of this study indicates that surface conditions should be considered when assessing and training the joint position sense of the knee joint in clinical setting.

  • PDF

Modulating the Voltage-sensitivity of a Genetically Encoded Voltage Indicator

  • Jung, Arong;Rajakumar, Dhanarajan;Yoon, Bong-June;Baker, Bradley J.
    • Experimental Neurobiology
    • /
    • v.26 no.5
    • /
    • pp.241-251
    • /
    • 2017
  • Saturation mutagenesis was performed on a single position in the voltage-sensing domain (VSD) of a genetically encoded voltage indicator (GEVI). The VSD consists of four transmembrane helixes designated S1-S4. The V220 position located near the plasma membrane/extracellular interface had previously been shown to affect the voltage range of the optical signal. Introduction of polar amino acids at this position reduced the voltage-dependent optical signal of the GEVI. Negatively charged amino acids slightly reduced the optical signal by 33 percent while positively charge amino acids at this position reduced the optical signal by 80%. Surprisingly, the range of V220D was similar to that of V220K with shifted optical responses towards negative potentials. In contrast, the V220E mutant mirrored the responses of the V220R mutation suggesting that the length of the side chain plays in role in determining the voltage range of the GEVI. Charged mutations at the 219 position all behaved similarly slightly shifting the optical response to more negative potentials. Charged mutations to the 221 position behaved erratically suggesting interactions with the plasma membrane and/or other amino acids in the VSD. Introduction of bulky amino acids at the V220 position increased the range of the optical response to include hyperpolarizing signals. Combining The V220W mutant with the R217Q mutation resulted in a probe that reduced the depolarizing signal and enhanced the hyperpolarizing signal which may lead to GEVIs that only report neuronal inhibition.

A study on potassium deficiency symptoms of flue-cured tobacco. (Interrelationship of nitrogen and potassium contents in leaves of stalk position applied with fertilizer levels) (황색종잎담배의 칼륨결핍증에 관한 연구 (시비수준에 따른 엽위 및 엽부위별 질소와 칼륨함량의 상호관계))

  • 홍순달;이윤환;김재정
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.4 no.1
    • /
    • pp.29-35
    • /
    • 1982
  • Potassium deficiency symptoms were studied with flue-cured tobacco which was applied with different levels of compound fertilizer (10-15-20) ; 75kg, 100hg, and 125kg/10a. Ratio of N/$K_2O$ in leaves was increased from bottom to top stalk position due to the increase of nitrogen content in leaves. Nitrogen content in leaves was increased from stalk to tip as wall as from midrib to laminae, but vice versa in potassium content. Consequently, resulting in potassium deficiency symptoms in tip of leaves. Rate of reabsorption by rainfall during the latter part of growth was highest at top stalk position in case of nitrogen, but lowest in potassium. This observation was more evident with higher application rate of fertilizer. Nitrogen content of about 4 % in leaves of top stalk position applied with 125kg/10a was maintained up to 85days after trans planting. No increase in potassium in upper leaves was observed over the level of 100kg/10a fertilizer application. As the result, N/$K_2O$ ratio in leaves of top stalk position applied with 125kg/10a was kept at more than 1.0 up to 85days after transplanting, but it was less than 0.9 at 65days after tracts planting with less than 100kg/10a fertilizer application.

  • PDF

Autonomic Nervous System Changes Associated with Respiratory Cycle and Posture (호흡 주기와 자세에 따른 자율신경계의 변화)

  • Song, Seongin;Goo, Bongoh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.2
    • /
    • pp.17-23
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate whether the respiratory cycle and posture can modulate the autonomic nervous system. Methods : Thirty-two healthy men and women, aged 20-30 years, were enrolled in this study. We conducted 2-second and 6-second respiratory cycle with the subjects in standing, sitting, and supine positions, respectively. Their heart rate variability was measured in each position for both cycle lengths. Results : The low frequency/high frequency (LF/HF) ratio is derived from heart rate variability. In the 2-second respiratory cycles, the LF/HF ratios were highest in standing, sitting, and supine position in descending order. There was a significant difference in heart rate between standing and sitting positions (P<.005). In addition, there was a significant difference in heart rate between standing and supine position (P<.000). In the 6-second respiratory cycles, the LF/HF ratios were again highest in a standing, sitting, and supine position in descending order. However, posture was not found to make a significant difference in this case. Conclusion : Respiratory cycle and posture effectively modulated the autonomic nervous system. Further studies of the clinical application of these results should be conducted.

A Study on the Effect of Fatigue and Crack Propagation Behavior in Spot Weld of High Strength Steel( I ) - Experimental Examination - (고장력 강판의 점용접부에서 면내 굽힘 모멘트가 피로특성 및 균열 성장 거동에 미치는 영향에 관한 연구(I) - 실험적 검토 -)

  • 성기찬;장경복;정진우;김기순;강성수
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.112-117
    • /
    • 2001
  • The factor affecting on the fatigue strength of spot welded specimen have been studied. To analyze and predict crack initiation position and propagation directions on the spot welded area are very important for strength design of the automobile body structure. In fact, there are a various of loads in running automobile but, it is impossible to replay like an actual conditions in the laboratory. So, in this study tensile-shear type and in-plane bending type specimens were used in fatigue test and includes an analysis of fatigue crack initiation position and propagation directions about earth specimens. The results obtained in the present study are summarized as follows: 1. In tensile-shear type fatigue test, the region of fatigue crack initiation position was affected by out-of-plane bending deformation due to bending angle. 2 In in-plane bending type fatigue test, the behavior of fatigue crack initiation position and propagation derections due to angle between upper plate and lower plate was dominated by magnitude of in-plane bending moment.

  • PDF

A Study on the Relation between Treatment posture and Musculoskeletal disorders Between Dental hygienist and Dental hygiene student some areas (일부지역 치과위생사와 치위생과 재학생의 진료자세와 통증과의 관계연구)

  • Kwag, Jung-Suk;Jang, Sun-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.381-393
    • /
    • 2007
  • The objectives of this study was to suggest for prophylatic of Musculoskeletal system disorders in Dental Hyginists and Dental hygiene students to maintain good posture in the dental hygiene curriculum. This study was carried with 100 dental hygienists in "M" city located in Jolla Province and 82 college students majoring in dental hygiene. The results were as follows: 1. During the operators' medical treatment, 41.7% answered that the patients' head was located in the operators' chest during their treatment. Also, 58.3% answered that the patients' head was located in the operators' abdomen. For this reason, 81.3% said that the patients' mouth became close to the operators' eyes - less than 30cm. And 65.1% said that they performed an operation in various directions. 2. The most common posture -between the position of operating and the position of assisting- is the position of operationg 1. The position of operationg 1 and 5 have an effect on the waist, and the position of assisting 3 has an effect on pains of the waist, bottoms, knees, ankles and feet. 3. The common symptoms of musculoskeletal system disorders in dental hygienists and student was the neck ache and the shoulders, and was followed by the lower back. From the cases that they visited in health care or apothecary to the above pain, symptoms were highest in the shoulders(18.3%) and were followed by the lower back(13.4%) and neck(9.1%). 4. On The necessity of education related to, According to researches, 96.3% college students and 92.5% dental hygienists answered that education related to Musculoskeletal system disorders is necessary. 5. In this study, I have 3 limitations. First, the subject of survey was selected for specific people in the specific city, Second, the personal judgment was made in judging the relations of the position of operating, the position of assisting and the aches. Third, the relations of the position of operating, the position of assisting and the aches don't have supporting medical evidences. Therefore, this study will be carried on more people with more objectives and medical method.

  • PDF

Design of a Radiation Spectroscopy Detector using a Spherical Scintillator and Development of a Radiation Source Position Tracking System (구형의 섬광체를 이용한 방사선 스펙트로스코피 검출기 설계 및 방사선원 위치 추적 시스템 개발)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • A radiation spectroscopy detector using a spherical scintillator was designed, and a system was developed to track the position of a radiation source using several detectors. The position tracking algorithm was designed based on the theory that the number of radiations decreases according to the inverse square law of distance, and the position of the radiation source was calculated by measuring the number of radiations generated from the radiation sources at various positions. The radiation generated from the radiation source is detected by different coefficients in each detector, and the difference between these detected coefficients varies in proportion to the inverse square of the distance. Geant4 Application for Tomographic Emission (GATE) simulation was performed to verify and evaluate the performance of the designed radiation source position tracking system, and radiation generated from radiation sources placed at different positions was counted with each detector. The number of measured radiations was tracked through the radiation source position tracking algorithm, and the error between the actual radiation source position and the position calculated by the algorithm was evaluated. The error between the position of the actual radiation source and the calculated position was measured as an average of 0.11% on the X-axis and 0.37% on the Y-axis, and it was verified that the position can be measured very accurately.

Position Estimation of Switched Reluctance Motors Using Binary Observer (이원 관측기를 이용한 스위치드 릴럭턴스 모터의 위치 추정)

  • Shin, Jae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2008.11b
    • /
    • pp.95-97
    • /
    • 2008
  • The binary observer estimates the rotor position and rotor flux with alleviation of the high-frequency chattering, and retains the benefits achieved in the conventional sliding observer, such as robustness to parameter and disturbance variations. The position sensorless control of SRM under the load and inductance variation is verified by the experimental results.

  • PDF