• 제목/요약/키워드: implant impression

검색결과 109건 처리시간 0.023초

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

폐구인상채득법을 이용한 임플란트 인상채득 증례 (Implant impression using closed mouth impression technique: a case report)

  • 김소연;김주현;정경화;전혜미;강은숙;윤미정
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.223-229
    • /
    • 2017
  • 단일 치아의 인상채득을 위해서는 바이트 트레이를 이용한 폐구인상법이 선호된다. 그러나 임플란트 인상채득을 위해서는 단일치와 다수치 구분 없이 편악 트레이를 이용한 개구인상법이 주로 사용되고 있다. 바이트 트레이를 이용하는 폐구인상법은 시간이 절약되고 재료가 적게 들며, 모형의 교합기 부착 시 상하악 악간 위치 관계 오차 발생 확률이 적다. 본 증례에서는 2 가지 종류의 폐구인상용 코핑을 이용해 바이트 트레이로 인상채득 후 단일 임플란트 고정성 보철물을 제작함에 있어 만족할 만한 결과를 얻어 보고하고자 한다.

Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

  • Jo, Si-Hoon;Kim, Kyoung-Il;Seo, Jae-Min;Song, Kwang-Yeob;Park, Ju-Mi;Ahn, Seung-Geun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.128-133
    • /
    • 2010
  • PURPOSE. The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS. The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with $10^{\circ}$ of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (${\alpha}$= .05), and the statistical significance was set at P < .05. RESULTS. The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION. Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and $10^{\circ}$ mesial angulated groups.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

인상채득 방법이 임플란트 보철 작업모형의 정확도에 미치는 영향 (EFFECT OF IMPRESSION TECHNIQUES ON ACCURACY OF MASTER CASTS FOR IMPLANT PROSTHESES)

  • 홍은희;한동후
    • 대한치과보철학회지
    • /
    • 제32권3호
    • /
    • pp.445-454
    • /
    • 1994
  • Osseointegrated implant prostheses are to provide normal function without compromising the unique interaction between the tissue and the implant. The essential requirement for the osseointegrated implant prostheses is passive fit of abutment. Therefore, the impression must be accurate and reproduciable since the resultant master cast precisely duplicates the clinical condition. The purpose of this study was to compare the accuracy of the master casts obtained from five impression techniques. Group 1 : To take impression with indirect technique and Impregum F. Group 2 : To take impression with unsplinted direct technique and Impregum F. Group 3 : To take impression with splinted direct technique and Impregum F. Group 4 : To take impression with unsplinted direct technique and Xanthano. Group 5 : To take impression with splinted dierct technique and Xanthano. The results were as follow : 1. In taking impression of Impregum F, there was no significant difference between to use of indirect technique and unsplinted direct technique.(p<0.05) 2. Unsplinted direct technique with Impregum F is less accurate than splinted direct technique with Impregum F or Xanthano and unsplinted direct technique with Xanthano.(p<0.05). 3. There was no significant difference between splinted direct technique with Impregum F and unsplinted direct technique with Xanthano.(p<0.05) 4. Splinted direct technique reproduce more accurate than unsplinted direct technique.(p<0.05) 5. Impression plaster produced less distortion than polyether.(p<0.05) As a result, splinted direct technique with Xanthano was the most accurate technique. As a result, splinted direct technique with Xanthano was the most accurate technique in this study. In addition to dimensinal changes in the materials used, positional errors were also attributed to the mechanical components used in the transfer porocess. Although the errors measured were relatively small, this study demonstrates the potential for distortions with the transfer technique used. Further study is indicated that ?the technique will be able to reproduce the intraoral relationship of implant fixtures reliably and predictably.

  • PDF

Strain gauge를 사용한 임플랜트 인상법의 정확도 비교 (A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE)

  • 한인택;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil;Park, Sang-Hun;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.66-70
    • /
    • 2014
  • A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례 (Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report)

  • 장윤정;김홍준;송미경;문지은;이한라;박찬익
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.234-243
    • /
    • 2015
  • 디지털 기술의 발달로 무치악 부위의 임플란트 수복 시 그 진단과 치료 과정 전반에 걸쳐 구강 내 3차원 정보를 데이터화하여 보철물을 제작하는 것이 가능해졌다. 전통적인 인상채득 방식을 이용하여 모델을 만들고 이것을 스캔하여 보철물을 제작하던 CAD/CAM 이용 방식에서 벗어나 디지털 인상 코핑(scanbody)을 사용함으로써 모델 없이 디지털 인상을 채득하고 임플란트 임시 보철물 및 해부학적 지대주를 제작하는 술식으로 변화하고 있다. 그러나 아직 이러한 술식은 활발히 이루어지고 있지 않으며 특히 심미성이 요구되어 연조직 외형의 인기가 중요한 상악 전치부 임플란트 즉시 부하에서의 사용은 그 사례가 많지 않다. 이에 따라 본 증례 보고에서는 3명의 상악 전치부 단일 임플란트 수복 환자에서 디지털 인상 코핑(scanbody)을 체결한 후 구강 내 스캐너인 CEREC Omnicam (Sirona, Bensheim, Germany) 또는 Trios (3shape, Copenhagen, Denmark)로 디지털 인상채득을 통해 임플란트 지대주 및 임시 보철물을 제작하였다. 그 결과 디지털 인상채득을 통한 편리성, 정확성 그리고 최종 보철물의 양호한 심미성을 얻어 보고하고자 한다.

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

인상채득방법이 임플란트 주모형의 정확성에 미치는 영향 (EFFECT OF IMPRESSION TECHNIQUE ON THE ACCURACY OF MASTER CAST FOR IMPLANT PROSTHESIS)

  • 김영오;양홍서
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.238-247
    • /
    • 2004
  • Statement of problem: Major objective in making on implant-supported prosthesis is the production of superstructure that exhibits a passive fit when connected to multiple abutments. One requirement to ensure passive fit is to make an accurate impression. Purpose : The purpose of this study was to compare the accuracy of master cast fabricated by using different impression methods at the different impression levels. Material and method: The master model used in this study was resin block having low implant analogs. Impression method studied were 1) direct method on fxiture level (Group FIX-D), 2) indirect method on fixture level(Group FIX-I), 3) modified indirect method on fixture level(Group FIX-M), 4) direct method on abutment level(Group AB-D) and 5) indirect method on abutment level(Group AB-I). Each of the five groups took 10 impressions. Fifty impressions were made for master cast by using Impregum $F^{(R)}$ impression material loaded on individual tray. Three dimensional measuring microscope was used to measure the inter-implant distance. Error rate of each inter-implant distance were calculated and evaluated. Results : The results were as follows. 1. Group FIX exhibited higher accuracy than group AB. 2. In group FIX, modified indirect method showed the highest accuracy, while indirect method showed the lowest accuracy. In group Ab, indirect method showed the higher accuracy than direct method. 3. Group FIX showed larger horizontal error than group AB. But, group AB showed the larger vertical error than group FIX. 4. Group Fix-M showed smallest vertical and horizontal error. Conclusion: An impression method have more effect on accuracy of master model than an impression level. A modified indirect method showed smallest vertical and horizontal error.