DOI QR코드

DOI QR Code

Implant overdenture impressions using a dynamic impression concept

  • Lee, Byung-Kil (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Park, Sang-Hun (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Lee, Cheong-Hee (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Cho, Jin-Hyun (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
  • 투고 : 2013.05.07
  • 심사 : 2013.11.05
  • 발행 : 2014.02.28

초록

A dynamic impression is a functional impression that records the functional movement of the patient's own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

키워드

참고문헌

  1. Chen IC, Brudvik JS, Mancl LA, Rubenstein JE, Chitswe K, Raigrodski AJ. Freedom of rotation of selected overdenture attachments: an in vitro study. J Prosthet Dent 2011;106:78-86. https://doi.org/10.1016/S0022-3913(11)60099-1
  2. Uludag B. An alternate pressure-free functional impression technique for implant-retained overdentures. J Oral Implantol 2010;36:205-7. https://doi.org/10.1563/AAID-JOI-D-09-00036
  3. Uludag B, Ozturk O, Celik G. Alternate functional impression technique for implant-retained overdentures. J Prosthet Dent 2007;97:242-3. https://doi.org/10.1016/j.prosdent.2007.02.010
  4. Uludag B, Cogalan K, Polat S. An alternative impression technique for implant-retained overdentures with locator attachments. J Oral Implantol 2010;36:451-3. https://doi.org/10.1563/AAID-JOI-D-09-00101
  5. Jannesar S, Siadat H, Alikhasi M. A dual impression technique for implant overdentures. J Prosthodont 2007;16:327-9. https://doi.org/10.1111/j.1532-849X.2007.00193.x
  6. Cho GC, Landesman M, Adomian JG. An alternative altered cast technique for a distal extension removable partial denture. J Calif Dent Assoc 1997;25:377-80.
  7. Razek MK. Assessment of tissue conditioning materials for functional impressions. J Prosthet Dent 1979;42:376-80. https://doi.org/10.1016/0022-3913(79)90135-5
  8. McCarthy JA, Moser JB. Tissue conditioners as functional impression materials. J Oral Rehabil 1978;5:357-64. https://doi.org/10.1111/j.1365-2842.1978.tb01254.x
  9. Wilson HJ, Tomlin HR, Osborne J. The assessment of temporary soft materials used in prosthetics. Br Dent J 1969;126: 303-6.
  10. Elsyad MA, El-Waseef FA, Al-Mahdy YF, Fouad MM. A comparison of mandibular denture base deformation with different impression techniques for implant overdentures. Clin Oral Implants Res 2013;24:127-33. https://doi.org/10.1111/j.1600-0501.2011.02395.x

피인용 문헌

  1. Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture vol.54, pp.3, 2016, https://doi.org/10.4047/jkap.2016.54.3.246
  2. An alternative impression technique based on McLean's functional impression concept vol.55, pp.1, 2017, https://doi.org/10.4047/jkap.2017.55.1.32
  3. Causes of failed implant attachments and application of double crown implant overdenture in one patient vol.56, pp.4, 2018, https://doi.org/10.4047/jkap.2018.56.4.368
  4. 하악 Milled Bar 임플란트 피개의치에서 12년 간의 임플란트 주변 치주조직 및 의치의 변화 vol.59, pp.1, 2021, https://doi.org/10.4047/jkap.2021.59.1.55