Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study  

Jo, Si-Hoon (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Kim, Kyoung-Il (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Seo, Jae-Min (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Song, Kwang-Yeob (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Park, Ju-Mi (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Ahn, Seung-Geun (Department of Prosthodontics, College of Dentistry, Chonbuk National University)
Publication Information
The Journal of Advanced Prosthodontics / v.2, no.4, 2010 , pp. 128-133 More about this Journal
Abstract
PURPOSE. The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS. The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with $10^{\circ}$ of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (${\alpha}$= .05), and the statistical significance was set at P < .05. RESULTS. The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION. Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and $10^{\circ}$ mesial angulated groups.
Keywords
Impression coping; Implant angulation; Master cast accuracy;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Rubenstein JE, Ma T. Comparison of interface relationships between implant components for laser-welded titanium frameworks and standard cast frameworks. Int J Oral Maxillofac Implants 1999;14:491-5.
2 Assif D, Fenton A, Zarb G, Schmitt A. Comparative accuracy of implant impression procedures. Int J Periodontics Restorative Dent 1992;12:112-21.
3 Carr AB, Master J. The accuracy of implant verification casts compared with casts produced from a rigid transfer coping technique. J Prosthodont 1996;5:248-52.   DOI   ScienceOn
4 Carr AB. Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991;6:448-55.
5 Kan JY, Rungcharassaeng K, Bohsali K, Goodacre CJ, Lang BR. Clinical methods for evaluating implant framework fit. J Prosthet Dent 1999;81:7-13.   DOI   ScienceOn
6 Barrett MG, de Rijk WG, Burgess JO. The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 1993;2:75-82.   DOI   ScienceOn
7 Michaels GC, Carr AB, Larsen PE. Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1997;83:198-205.   DOI   ScienceOn
8 Jemt T, Lekholm U, Johansson CB. Bone response to implantsupported frameworks with differing degrees of misfit preload: in vivo study in rabbits. Clin Implant Dent Relat Res 2000;2:129-37.   DOI   ScienceOn
9 Burns J, Palmer R, Howe L, Wilson R. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-5.   DOI   ScienceOn
10 Carr AB, Gerard DA, Larsen PE. The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. J Prosthet Dent 1996;76:500-9.   DOI   ScienceOn
11 Lee H, Ercoli C, Funkenbusch PD, Feng C. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 2008;99:107-13.   DOI   ScienceOn
12 Ma T, Nicholls JI, Rubenstein JE. Tolerance measurements of various implant components. Int J Oral Maxillofac Implants 1997;12:371-5.
13 Phillips KM, Nicholls JI, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three-dimensional analysis. Int J Oral Maxillofac Implants 1994;9:533-40.
14 Rodney J, Johansen R, Harris W. Dimensional accuracy of two implant impression copings. J Dent Res 1991;70:385.
15 Conrad HJ, Pesun IJ, DeLong R, Hodges JS. Accuracy of two impression techniques with angulated implants. J Prosthet Dent 2007;97:349-56.   DOI   ScienceOn
16 Wee AG. Comparison of impression materials for direct multi-implant impressions. J Prosthet Dent 2000;83:323-31.   DOI   ScienceOn
17 Wenz HJ, Hertrampf K. Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 2008;23:39-47.
18 Assuncao WG, Filho HG, Zaniquelli O. Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 2004;13:358-66.
19 Lee H, So JS, Hochstedler JL, Ercoli C. The accuracy of implant impressions: a systematic review. J Prosthet Dent 2008;100:285-91.   DOI   ScienceOn
20 Choi JH, Lim YJ, Yim SH, Kim CW. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models. Int J Oral Maxillofac Implants 2007;22:761-8.
21 Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.   DOI
22 Jemt T, Book K. Prosthesis misfit and marginal bone loss in edentulous implant patients. Int J Oral Maxillofac Implants 1996;11:620-5.
23 Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410.   DOI   ScienceOn
24 Rangert B, Jemt T, Jorneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989;4:241-7.