Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

Implant placement using a newly developed CT-based guide program and subtractive manufacturing: case reports (새로 개발된 3차원 영상 기반의 임플란트 가이드 프로그램과 삭제 공정을 이용한 임플란트 계획 및 식립: 증례보고)

  • Park, Jung-Wan;Kim, Kyung-Rok;Kang, Hye-Won;Lee, Kyu-Bok;Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2015
  • Computer-guided surgery utilizing computed tomography is advantageous in placing implants precisely and conveniently. The purpose of the cases was to report a newly developed CT-based guide fabrication program and subtractive manufacturing using resin block. The guided surgery with the program and subtractive manufacturing allows not only precise translation of the treatment plan, but also offers additional significant benefits.

Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립)

  • Kim, Soung Min;Kim, Myung Joo;Lee, Jee Ho;Myoung, Hoon;Lee, Jong Ho;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Buttock Augmentation with Elastomer Implants (엘라스토머 임플란트를 사용한 엉덩이 확대 성형술)

  • Park, Bong-Kwon;Kim, Youn-Hwan;Ahn, Hee-Chang
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.182-188
    • /
    • 2011
  • Purpose: The buttocks region has been associated with allure and sex appeal for centuries. Gluteal implants enable buttocks remodeling in a way that is not possible in other methods. One of the reasons that render gluteal implant surgeries unpopular is the fear of complications, the main problems being seroma, wound dehiscence, extrusion, and a visible or palpable implant. The authors present the XYZ technique, which provides anatomical reference points to guide the intramuscular dissection procedure in a feasible and safe way, resulting in a lower complication rate. Methods: The XYZ procedure was done for buttock augmentation on 8 patients from December 2009 to June 2010. Patient's ages ranged from 27 to 44 with a mean age of 36. Seven patients were applied the 250cc sized Elastomer implants with one patient 290cc sized implant. Preoperative marking was done with the patients in the standing position. Bisection of the gluteus maximus muscle was done at the midpoint thickness to create a plane for implant insertion, which is called the sandwich plane. Results: The 8 cases were performed safely without major complications. However one patient had minor wound dehiscence, and was managed with conservative treatment. Another patient had a discomfort on the buttocks for a long time. The patients were followed up for average 6 months. All patients were satisfied with the aesthetic results. Conclusion: In performing the XYZ technique for gluteal augmentation, the surgeon must split the muscle into two equal halves with anatomical reference points to guide the muscle detachment in a symmetrical way at an adequate depth. This method provides a guideline for the surgeon in determining the ideal plane during intramuscular dissection and gives predictable results with low complication rates. Intramuscular gluteoplasty with gluteal implants offers predictable, aesthetically pleasing results without contour irregularities and only a low incidence of major complications.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.

Planning of Multiple Tooth Implant Placement Using the Standardized Data in Teeth Size and Position (표준 치아 크기 및 배열 정보를 이용한 다중 치아 임플란트 식립계획 방안)

  • Park, Hyung-Wook;Park, Sang-Jin;Park, Hyungjun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.348-356
    • /
    • 2015
  • It is important to devise methods for assisting dentists to consistently determine implant positions and directions and to accurately perform drilling tasks during dental implant surgery. In this paper, we propose a novel approach to tooth implant placement planning which deals with the determination of the positions and directions of multiple implant fixtures for a set of missing mandibular teeth and suggests the selection of the sizes and types of the implant fixtures. We combine Korean standard data in the sizes and positions of human teeth with the patient specific 3D models of mandibular jawbones, nerve curves, and neighboring teeth around the missing teeth in order to determine the positions and directions of the implant fixtures for the missing teeth. Using the geometric and spatial information of the jawbones, the teeth and the implant fixtures, we can construct the 3D models of surgical guide stents which are crucial to perform drilling tasks with ease and accuracy. Adopted in 3D simulation of dental implant placement, the approach can provide surgeon students with good educational contents. We also expect that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.