DOI QR코드

DOI QR Code

Implant placement using a newly developed CT-based guide program and subtractive manufacturing: case reports

새로 개발된 3차원 영상 기반의 임플란트 가이드 프로그램과 삭제 공정을 이용한 임플란트 계획 및 식립: 증례보고

  • Park, Jung-Wan (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Kim, Kyung-Rok (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Kang, Hye-Won (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Lee, Kyu-Bok (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Lee, Du-Hyeong (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
  • 박정완 (경북대학교 치의학전문대학원 치과보철학교실) ;
  • 김경록 (경북대학교 치의학전문대학원 치과보철학교실) ;
  • 강혜원 (경북대학교 치의학전문대학원 치과보철학교실) ;
  • 이규복 (경북대학교 치의학전문대학원 치과보철학교실) ;
  • 이두형 (경북대학교 치의학전문대학원 치과보철학교실)
  • Received : 2014.11.12
  • Accepted : 2015.01.08
  • Published : 2015.03.31

Abstract

Computer-guided surgery utilizing computed tomography is advantageous in placing implants precisely and conveniently. The purpose of the cases was to report a newly developed CT-based guide fabrication program and subtractive manufacturing using resin block. The guided surgery with the program and subtractive manufacturing allows not only precise translation of the treatment plan, but also offers additional significant benefits.

컴퓨터 단층영상에 기반한 임플란트의 삼차원 컴퓨터 유도 수술은 임플란트 가이드를 이용함으로써 수술시 정확도와 편의성을 향상시킨다. 본 증례에서는 최근에 개발된 임플란트 가이드를 제작 프로그램을 이용하여 가이드를 설계하고 아크릴릭 레진을 절삭하는 방식으로 제작하여 임상에 적용하였다. 본 프로그램을 이용한 가이드의 설계와 제작시 이로운 점이 있었기에 이를 보고하는 바이다.

Keywords

References

  1. Tolstunov L. Implant zones of the jaws: implant location and related success rate. J Oral Implantol 2007;33:211-20. https://doi.org/10.1563/1548-1336(2007)33[211:IZOTJI]2.0.CO;2
  2. Buser D, Martin W, Belser UC. Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants 2004;19 Suppl:43-61.
  3. Beretta M, Poli PP, Maiorana C. Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study. J Periodontal Implant Sci 2014;44:184-93. https://doi.org/10.5051/jpis.2014.44.4.184
  4. Tarnow DP, Cho SC, Wallace SS. The effect of inter- implant distance on the height of inter-implant bone crest. J Periodontol 2000;71:546-9. https://doi.org/10.1902/jop.2000.71.4.546
  5. Garber DA, Belser UC. Restoration-driven implant placement with restoration-generated site development. Compend Contin Educ Dent 1995;16:796, 798-802, 804.
  6. Orentlicher G, Abboud M. Guided surgery for implant therapy. Oral Maxillofac Surg Clin North Am 2011;23:239-56, v-vi. https://doi.org/10.1016/j.coms.2011.01.008
  7. van Steenberghe D, Glauser R, Blomback U, Andersson M, Schutyser F, Pettersson A, Wendelhag I. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res 2005;7 Suppl 1:S111-20. https://doi.org/10.1111/j.1708-8208.2005.tb00083.x
  8. Van de Velde T, Glor F, De Bruyn H. A model study on flapless implant placement by clinicians with a different experience level in implant surgery. Clin Oral Implants Res 2008;19:66-72.
  9. Patras M, Martin W, Sykaras N. A novel surgical template design in staged dental implant rehabilitations. J Oral Maxillofac Res 2012;3:e5.
  10. Kennedy BD, Collins TA Jr, Kline PC. Simplified guide for precise implant placement: a technical note. Int J Oral Maxillofac Implants 1998;13:684-8.
  11. D'Souza KM, Aras MA. Types of implant surgical guides in dentistry: a review. J Oral Implantol 2012;38:643-52. https://doi.org/10.1563/AAID-JOI-D-11-00018
  12. Becker CM, Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000;83:248-51. https://doi.org/10.1016/S0022-3913(00)80018-9
  13. Marquardt P, Witkowski S, Strub J. Three-dimensional navigation in implant dentistry. Eur J Esthet Dent 2007;2:80-98.
  14. Cassetta M, Stefanelli LV, Giansanti M, Calasso S. Accuracy of implant placement with a stereolithographic surgical template. Int J Oral Maxillofac Implants 2012;27:655-63.
  15. Pattanaik S, Pattanaik BK. Fabrication of a surgical guide with help of a milling machine by ridge mapping method. J Indian Prosthodont Soc 2013;13:61-5. https://doi.org/10.1007/s13191-012-0199-5
  16. Azari A, Nikzad S. Computer-assisted implantology: historical background and potential outcomesa review. Int J Med Robot 2008;4:95-104. https://doi.org/10.1002/rcs.188