DOI QR코드

DOI QR Code

Implant-assisted full denture using digital guide: a case report

무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례

  • Kim, Wook Tae (Department of Dental Technology and Science, The College of Biotechnology and Health, Shinhan University)
  • 김욱태 (신한대학교 바이오-생태 보건대학 치기공학과)
  • Received : 2021.11.01
  • Accepted : 2021.12.10
  • Published : 2021.12.30

Abstract

By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

Keywords

References

  1. Seitz H, Tille C, Irsen S, Bermes G, Sader R, Zeilhofer HF. Rapid prototyping models for surgical planning with hard and soft tissue representation. Int Congr Ser. 2004;1268:567-572. https://doi.org/10.1016/j.ics.2004.03.139
  2. Korean Council on Complete Denture Education. Prosthodontic treatment for edentulous patients. 2nd ed. Seoul: Dental Wisdom, 2014. p. 14-18.
  3. Lee JH, Kim DG, Park CJ, Cho LR. A literature review on implant assisted removable partial denture. J Dent Rehabil Appl Sci. 2012;28:179-190.
  4. Ohkubo C, Kobayashi M, Suzuki Y, Hosoi T. Effect of implant support on distal-extension removable partial dentures: in vivo assessment. Int J Oral Maxillofac Implants. 2008;23:1095-1101.
  5. DeBoer J. Edentulous implants: overdenture versus fixed. J Prosthet Dent. 1993;69:386-390. https://doi.org/10.1016/0022-3913(93)90186-R
  6. van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants. 2002;17:663-670.
  7. van Steenberghe D, Glauser R, Blomback U, Andersson M, Schutyser F, Pettersson A, et al. A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res. 2005;7 Suppl 1:S111-S120. https://doi.org/10.1111/j.1708-8208.2005.tb00083.x
  8. Marchack CB. An immediately loaded CAD/CAM-guided definitive prosthesis: a clinical report. J Prosthet Dent. 2005;93:8-12. https://doi.org/10.1016/j.prosdent.2004.10.012
  9. Balshi SF, Wolfinger GJ, Balshi TJ. Surgical planning and prosthesis construction using computed tomography, CAD/CAM technology, and the Internet for immediate loading of dental implants. J Esthet Restor Dent. 2006;18:312-323; discussion 324-325. https://doi.org/10.1111/j.1708-8240.2006.00029.x
  10. Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hammerle CH, et al. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2009;24 Suppl:92-109.