Acknowledgement
In memoriam, the authors extend their deepest gratitude to Prof. Dr. Alexander Tadeu Sverzut for his invaluable contributions to this research.
References
- Special Committee to Revise the Joint AAE/AAOMR Position Statement on use of CBCT in Endodontics. AAE and AAOMR joint position statement: use of cone beam computed tomography in endodontics 2015 update. Oral Surg Oral Med Oral Pathol Oral Radiol 2015; 120: 508-12. https://doi.org/10.1016/j.oooo.2015.07.033
- Patel S, Brown J, Semper M, Abella F, Mannocci F. European Society of Endodontology position statement: use of cone beam computed tomography in endodontics: European society of endodontology (ESE) developed by. Int Endod J 2019; 52: 1675-8. https://doi.org/10.1111/iej.13187
- Patel S, Brown J, Pimentel T, Kelly RD, Abella F, Durack C. Cone beam computed tomography in endodontics - a review of the literature. Int Endod J 2019; 52: 1138-52. https://doi.org/10.1111/iej.13115
- Oenning AC, Jacobs R, Salmon B. ALADAIP, beyond ALARA and towards personalized optimization for paediatric cone-beam CT. Int J Paediatr Dent 2021; 31: 676-8. https://doi.org/10.1111/ipd.12797
- Freitas DQ, Nascimento EHL, Vasconcelos TV, Noujeim M. Diagnosis of external root resorption in teeth close and distant to zirconium implants: influence of acquisition parameters and artefacts produced during cone beam computed tomography. Int Endod J 2019; 52: 866-73. https://doi.org/10.1111/iej.13065
- Freitas DQ, Vasconcelos TV, Noujeim M. Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography. Clin Oral Investig 2019; 23: 1263-70. https://doi.org/10.1007/s00784-018-2558-z
- Gaeta-Araujo H, Nascimento EH, Oliveira-Santos N, Pinheiro MC, Coelho-Silva F, Oliveira-Santos C. Influence of adjacent teeth restored with metal posts in the detection of simulated internal root resorption using CBCT. Int Endod J 2020; 53: 1299-306. https://doi.org/10.1111/iej.13348
- Marinho Vieira LE, Diniz de Lima E, Peixoto LR, Oliveira Pinto MG, Sousa Melo SL, Oliveira ML, et al. Assessment of the influence of different intracanal materials on the detection of root fracture in birooted teeth by cone-beam computed tomography. J Endod 2020; 46: 264-70. https://doi.org/10.1016/j.joen.2019.10.028
- Fontenele RC, Farias Gomes A, Nejaim Y, Freitas DQ. Do the tube current and metal artifact reduction influence the diagnosis of vertical root fracture in a tooth positioned in the vicinity of a zirconium implant? A CBCT study. Clin Oral Investig 2021; 25: 2229-35. https://doi.org/10.1007/s00784-020-03538-4
- Gaeta-Araujo H, Silva de Souza GQ, Freitas DQ, de Oliveira-Santos C. Optimization of tube current in cone-beam computed tomography for the detection of vertical root fractures with different intracanal materials. J Endod 2017; 43: 1668-73. https://doi.org/10.1016/j.joen.2017.04.003
- Nascimento EH, Fontenele RC, Santaella GM, Freitas DQ. Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant. Dentomaxillofac Radiol 2019; 48: 20190058.
- Fontenele RC, Nascimento EH, Santaella GM, Freitas DQ. Does the metal artifact reduction algorithm activation mode influence the magnitude of artifacts in CBCT images? Imaging Sci Dent 2020; 50: 23-30. https://doi.org/10.5624/isd.2020.50.1.23
- Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol 2011; 40: 265-73. https://doi.org/10.1259/dmfr/30642039
- Jones DE, Raine HC. Correspondence. Br J Radiol 1949; 22: 549-50. https://doi.org/10.1259/0007-1285-22-261-549-b
- Brand JW, Kuba RK, Braunreiter TC. An improved head-and-neck phantom for radiation dosimetry. Oral Surg Oral Med Oral Pathol 1989; 67: 338-46. https://doi.org/10.1016/0030-4220(89)90367-8
- Oliveira ML, Tosoni GM, Lindsey DH, Mendoza K, Tetradis S, Mallya SM. Influence of anatomical location on CT numbers in cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 115: 558-64. https://doi.org/10.1016/j.oooo.2013.01.021
- Candemil AP, Salmon B, Freitas DQ, Ambrosano GM, Haiter-Neto F, Oliveira ML. Metallic materials in the exomass impair cone beam CT voxel values. Dentomaxillofac Radiol 2018; 47: 20180011.
- Pauwels R, Stamatakis H, Bosmans H, Bogaerts R, Jacobs R, Horner K, et al. Quantification of metal artifacts on cone beam computed tomography images. Clin Oral Implants Res 2013; 24 Suppl A100: 94-9. https://doi.org/10.1111/j.1600-0501.2011.02382.x
- Pauwels R, Araki K, Siewerdsen JH, Thongvigitmanee SS. Technical aspects of dental CBCT: state of the art. Dentomaxillofac Radiol 2015; 44: 20140224.
- Kuusisto N, Abushahba F, Syrjanen S, Huumonen S, Vallittu P, Narhi T. Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study. Dentomaxillofac Radiol 2023; 52: 20230252.
- Khurana S, Parasher P, Creanga AG, Geha H. Effect of mandible phantom inclination in the axial plane on image quality in the presence of implant using cone-beam computer tomography. Cureus 2023; 15: e36630.
- Wanderley VA, Freitas DQ, Haiter-Neto F, Oliveira ML. Influence of tooth orientation on the detection of vertical root fracture in cone-beam computed tomography. J Endod 2018; 44: 1168-72. https://doi.org/10.1016/j.joen.2018.04.006
- Vanderstuyft T, Tarce M, Sanaan B, Jacobs R, de Faria Vasconcelos K, Quirynen M. Inaccuracy of buccal bone thickness estimation on cone-beam CT due to implant blooming: an ex-vivo study. J Clin Periodontol 2019; 46: 1134-43. https://doi.org/10.1111/jcpe.13183
- Wanderley VA, Nascimento EH, Gaeta-Araujo H, Oliveira-Santos C, Freitas DQ, Oliveira ML. Combined use of 2 cone-beam computed tomography scans in the assessment of vertical root fracture in teeth with intracanal material. J Endod 2021; 47: 1132-7. https://doi.org/10.1016/j.joen.2021.04.001
- Nascimento EH, Gaeta-Araujo H, Fontenele RC, Oliveira-Santos N, Oliveira-Santos C, Freitas DQ. Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT? Clin Oral Investig 2021; 25: 5281-91. https://doi.org/10.1007/s00784-021-03836-5
- Freitas DQ, Fontenele RC, Nascimento EH, Vasconcelos TV, Noujeim M. Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts. Dentomaxillofac Radiol 2018; 47: 20180151.
- Queiroz PM, Oliveira ML, Groppo FC, Haiter-Neto F, Freitas DQ. Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials. Clin Oral Investig 2018; 22: 419-23. https://doi.org/10.1007/s00784-017-2128-9