• Title/Summary/Keyword: impedance responses

Search Result 111, Processing Time 0.033 seconds

Design of a Microstrip Bandpass Filter Using Step Impedance Resonators and Tapped Input/Output (스텝 인피던스 공전기와 입출력 텝핑을 이용한 마이크로 스트립 대역통과 필터의 설계)

  • 박동철;박정일;이병남
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1728-1735
    • /
    • 1989
  • A design procedure for microstrip bandpass filters using step impedance resonators (SIR's) and tapped input/output to a conventional parallel coupled line bandpass filter is presented. The filter configuration consisting of both half-wavelength and SIR's suppreses to spurious resonance response near the second harmonics, while tapping techniques offer benefit in situations where the impractical. The measured frequency responses of the designed filter are in close agreement with the computed responses.

  • PDF

Quantitative damage identification in tendon anchorage via PZT interface-based impedance monitoring technique

  • Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.181-195
    • /
    • 2017
  • In this study, the severity of damage in tendon anchorage caused by the loss of tendon forces is quantitatively identified by using the PZT interface-based impedance monitoring technique. Firstly, a 2-DOF impedance model is newly designed to represent coupled dynamic responses of PZT interface-host structure. Secondly, the 2-DOF impedance model is adopted for the tendon anchorage system. A prototype of PZT interface is designed for the impedance monitoring. Then impedance signatures are experimentally measured from a laboratory-scale tendon anchorage structure with various tendon forces. Finally, damage severities of the tendon anchorage induced by the variation of tendon forces are quantitatively identified from the phase-by-phase model updating process, from which the change in impedance signatures is correlated to the change in structural properties.

Electrical/Dielectric Characterization of 2-Dimenisonal Electron Gas Layers Formed between LaAlO3 and SrTiO3

  • Park, Chan-Rok;Kwon, Kyeong-Woo;Do, Woo-ri;Park, Da-Hee;Baek, Senug-Hyub;Kim, Jin Sang;Hwang, in-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.366.2-366.2
    • /
    • 2014
  • Impedance spectroscopy allows for simultaneous characterization of interface-controlled materials and/or devices in terms of electrical and dielectric aspects. Recently, there have tremendous interests in 2-dimensional electron gas layers (2DEGs) involving $LaAlO_3$ and $SrTiO_3$ whose features incorporates extremely high mobility and carrier concentrations along with metallic responses unlike the constituents, $LaAlO_3$ and $SrTiO_3$. Impedance spectroscopy offers the following unique features, such as simultaneous determination of conductivity and dielectric constants, identification of electrical origins among bulk-, grain boundary-, and electrode-based responses. Impedance spectroscopy was applied to the 2DEG $LaAlO_3/SrTiO_3$ system, in order to extract the electrical and dielectric information operating in the 2DEG system. The unique responses of the 2DEG system are investigated in terms of temperature and device structures. The underlying mechanism of the 2DEG system is proposed with the aim to optimizing the high-mobility 2DEG responses and to expedite the associated devices towards the high-density integrated chips.

  • PDF

Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation

  • Huynh, Thanh-Canh;Lee, Kwang-Suk;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.15 no.2
    • /
    • pp.375-393
    • /
    • 2015
  • In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their performances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses.

Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges

  • Kim, Jeong-Tae;Park, Jae-Hyung;Hong, Dong-Soo;Cho, Hyun-Man;Na, Won-Bae;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • v.5 no.1
    • /
    • pp.81-94
    • /
    • 2009
  • A vibration-impedance-based monitoring method is proposed to predict the loss of prestress forces in prestressed concrete (PSC) girder bridges. Firstly, a global damage alarming algorithm using the change in frequency responses is formulated to detect the occurrence of damage in PSC girders. Secondly, a local damage detection algorithm using the change in electro-mechanical impedance features is selected to identify the prestress-loss in tendon and anchoring members. Thirdly, a prestress-loss prediction algorithm using the change in natural frequencies is selected to estimate the extent of prestress-loss in PSC girders. Finally, the feasibility of the proposed method is experimentally evaluated on a scaled PSC girder model for which acceleration responses and electro-mechanical impedances were measured for several damage scenarios of prestress-loss.

Numerical Simulation of Electro-Mechanical Impedance Response in Cable-Anchor Connection Interlace

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.11-23
    • /
    • 2011
  • In this study, a finite element(FE) analysis on electro-mechanical impedance response of cable-anchor connection interface under various anchor force is presented. In order to achieve the objective, the following approaches are implemented. Firstly, an interface washer coupled with piezoelectric(PZT) material is designed for monitoring cable-force loss. The interface washer is a small aluminum plate on which a PZT patch is surface-bonded. Cable-force loss could be monitored by installing the interface washer between the anchor plate and the anchorage of cable-anchor connection and examining the changes of impedance of the interface washer. Secondly, a FE model for cable-anchor connection is established to examine the effect of cable-force on impedance response of interface washer. Also, the effects of geometrical and material properties of the interface washer on impedance responses under various cable-forces are investigated. Finally, validation of the FE analysis is experimentally evaluated by a lab-scale cable-anchor connection.

A study on nonlinear seismic response analysis of building considering frequency dependent soil impedance in time domain

  • Nakamura, Naohiro
    • Interaction and multiscale mechanics
    • /
    • v.2 no.1
    • /
    • pp.91-107
    • /
    • 2009
  • In order to accurately estimate the seismic behavior of buildings, it is important to consider both nonlinear characteristics of the buildings and the frequency dependency of the soil impedance. Therefore, transform methods of the soil impedance in the frequency domain to the impulse response in the time domain are needed because the nonlinear analysis can not be carried out in the frequency domain. The author has proposed practical transform methods. In this paper, seismic response analyses considering frequency dependent soil impedance in the time domain are shown. First, the formulation of the proposed transform methods is described. Then, the linear and nonlinear earthquake response analyses of a building on 2-layered soil were carried out using the transformed impulse responses. Through these analyses, the validity and efficiency of the methods were confirmed.

Electrical Impedance Response Model of Concrete in Setting Process (응결 과정 콘크리트의 전기 임피던스 응답 해석 모델)

  • Shin, Sung Woo;Hwang, Garam;Lee, Chang Joon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.116-122
    • /
    • 2014
  • Assessment of setting process of concrete is important as it provides useful information to schedule concreting work in construction site. Electrical impedance measurement method, which utilizes the change of electrical resistance of concrete, has been applied to assess setting process of cement-based materials. However, the applicability of the method has been demonstrated only for cement paste and mortar. The main purpose of this research is to develop the electrical impedance based setting process assessment for concrete. To this end, electrical impedance response model for concrete should be developed in advance since it is essential to estimate the electrical resistance of concrete from measured impedance response. The electrical resistance of concrete is a key parameter for the setting process assessment. In this study electrical impedance responses of the concrete in setting process are measured and analyzed. Thereby, an electrical impedance response model of the liquid state concrete is developed and schematically validated.

Poisson Effect on Electromechanical Impedance of Unconstrained Piezoelectric Patch

  • Shin, Sung-Woo;Kwon, Oh-Heon
    • International Journal of Safety
    • /
    • v.8 no.2
    • /
    • pp.26-30
    • /
    • 2009
  • In this study, the Poisson effect on resonant frequency behaviors of the unconstrained piezoelectric patch is investigated. The electromechanical impedance models for the un-bonded patch are derived from the two existing bonded patch models and numerical analysis for a given piezoelectric material is performed. From the analysis, it is found that the Poisson effect is not important as long as the electromechanical impedance model is used to predict the locations of resonant frequencies. However, Poisson effect should be considered when predicting the location of the largest resonant frequency of the patch since the amplitude responses are different with the model used.

Effects of Electrical and Acoustical Variations for Loudspeaker due to Fabrication Processes (조립과정이 스피커의 전기 및 음향특성에 미치는 영향)

  • Park, Seok-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.155-159
    • /
    • 2004
  • In this paper, it was analyzed the characteristics of electrical and acoustical variations for loudspeaker due to fabrication processes. First, mass of each components of loudspeaker was measured by electric precision scale and performed statistical analysis. Second. Thiele-Small parameters of sample loudspeakers produced by unskilled students were identified by known mass parameter identification method using electrical impedance method and investigated on the variations of each parameter. Electrical impedance tests and acoustic frequency responses were measured on sample loudspeakers and variations were examined to grasp relationship between components variation and fabrication processes. Main factors to effect the changes of electrical impedance were concluded by fabrication processes errors not by components of loudspeaker.

  • PDF