• Title/Summary/Keyword: imaging techniques

Search Result 1,053, Processing Time 0.031 seconds

Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가)

  • Kwark, Cheol-Eun;Chung, June-Key;Lee, Myung-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI (Sestamibi) myocardial SPECT along with TI-201 tomographic Imaging has demonstrated wide application and high image quality sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow. The qualitative values of myocardial SPECT with Tc-99m-MIBI as well ds the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection (FBP) Is the common standard method for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected litter parameters such as cutoff frequencies and order (Butterworth case) The cutoff frequencies used in clinicAl practice partially remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for Identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable threshold of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Wyquist frequency would reveal severe degradation of radioactive distribution near inferior and/or inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Usefulness of Superparamagnetic Iron Oxide (SPIO) as a Negative Oral Contrast Agent in MR Cholangiopancreatography (자기공명 담관췌장초영술에서 음성 경구 조영제로 사용한 초상자성 산화철 제재의 유용성)

  • 이정민;송원규;이종덕
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.49-56
    • /
    • 2001
  • Purpose : To evaluate value of superparamagnetic iron oxide (SPIO) as a negative oral contrast agent in MR cholangiopancreatography (MRCP). Materials and methods : Forty-eight patients with suspected biliary tract or pancreatic diseases and six healthy volunteers were enrolled in this study. All MR images were obtained using a 1.5 T MR unit. MR-CP using fat-suppressed half-Fourier acquisition single-shot turbo spin echo (HASTE) and turbo spin echo (TSE) techniques were performed and reconstructed with maximal intensity projection (MIP). To determine the most optimal concentration of SPIO to obliterate the high signal intensity of water, a phantom experiment was conducted with various concentrations of SPIO-water mixture. Two radiologists evaluated pre- and postcontrast MRCPS. The contrast enhancement was assessed on the basis of loss of signal intensity in the stomach and duodenum. Results : In the phantom experiment, a significant increase of percentage of signal intensity loss (PSIL) occurred in concentration of 22.4 ugFe/ml (Feridex1 ml diluted with water 500 ml). Postcontrast MRCP showed an improved image quality compared with precontrast images. The rate of improvement in the diagnosis of diseases of the common bile duct and pancreatic duct was 25% (12/48). Conclusion : In patients with suspected biliary tract and pancreatic diseases, the SPIO is useful as a negative oral contrast agent for MRCP and provides an improvement of image quality.

  • PDF

A Neurobiological Measure of General Intelligence in the Gifted (뇌기능영상 측정법을 이용한 영재성 평가의 타당성 연구)

  • Cho, Sun-Hee;Kim, Heui-Baik;Choi, Yu-Yong;Chae, Jeong-Ho;Lee, Kun-Ho
    • Journal of Gifted/Talented Education
    • /
    • v.15 no.2
    • /
    • pp.101-125
    • /
    • 2005
  • We applied functional magnetic resonance imaging (fMRI) techniques to examine whether general intelligence (g) could be assessed using a neurobiological signal of the brain. Participants were students in a national science academy and several local high schools. They were administered diverse intelligence (RAPM and WAIS) and creativity tests (TTCT-figural and TTCT-verbal). Forty of them were scanned using fMRI while performing complex and simple g tasks. In brain regions of greater blood flow in complex compared with simple g tasks, the gifted group with an exceptional g level was not significantly different from the average group with an ordinary g level: both of them activated the lateral prefrontal, anterior cingulate, posterior parietal cortices. However, the activation levels of the gifted group were greater than those of the average group, particularly in the posterior parietal cortex. Correlation analysis showed that the activity of the posterior parietal cortex has the highest correlation ($(r=0.73{\sim}0.74)$) with individual g levels and other regions also have moderate correlation ($(r=0.53{\sim}0.66)$). On the other hand, two-sample t test showed a striking contrast in intelligence tests scores between the gifted and the average group, whereas it did not show in creativity tests scores. These results suggest that it is within the bounds of possibility that a neurobiological signal of the brain is used in the assessment of the gifted and also suggest that creativity has to be given a great deal of weight on the assessment of the gifted.

Thyroglobulin Measurement in Fine Needle Aspirates for Diagnosing Cervical Lymphnode Metastasis from Differentiated Thyroid Malignancy (갑상선암의 경부 림프절 전이 진단을 위한 미세침세척액 티로글로불린 측정법)

  • Ko, Hee-Young;Kim, Seung-Su;Lee, Chun-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.181-185
    • /
    • 2010
  • Purpose: Several studies report that detection of thyroglobulin (Tg) in fine-needle aspiration (FNA) biopsy washout fluid from lymph nodes identifies recurrences or metastases of differentiated papillary thyroid cancer (DPTC) in the neck with higher sensitivity and specificity than fine-needle aspiration cytology (FNAC). We evaluate the diagnostic efficacy and usefulness of Tg measurement in FNA washout fluid (FNA-Tg) and compare with FNAC. Materials and Methods: Forty-eight FNA samples of 37 patients who undergone ultrasonography to detect cervical lymph node metastasis of DPTC, were included for this study. Lymph node metastasis was confirmed by histopathologic examination or long-term imaging follow-up. Sensitivity, specificity and accuracy of FNA-Tg and FNAC were calculated. In 34 patients, we evaluated diagnostic accuracy of FNA-Tg according to the presence or absence of Tg antibody. Results: Sensitivity, specificity and accuracy of FNAC were 75.0%, 97.2% and 91.7%, respectively, and those of FNA-Tg were 100%, 88.9% and 91.7%, respectively. The presence of Tg antibody was not relevant to the diagnostic accuracy of FNA-Tg. Conclusion: FNA-Tg is a as accurate as FNAC with higher sensitivity. FNA-Tg and FNAC are complement techniques for diagnosing lymph node metastasis of DTPC.

  • PDF

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.4
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Early and Mid-term Changes of the Distal Aorta after Total Arch Replacement for Acute Type A Aortic Dissection

  • Choi, Chang Hu;Park, Chul Hyun;Jeon, Yang Bin;Lee, So Young;Lee, Jae Ik;Park, Kook Yang
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • Background: Total arch replacement (TAR) is being more widely performed due to recent advances in operative techniques and cerebral protective strategies. In this study, the authors reviewed the relationship between TAR and early- and mid-term changes of the false lumen after TAR in acute type A aortic dissection. Materials and Methods: Twenty-six patients (aged, $54.7{\pm}13.3$ years) who underwent TAR for acute type A dissection between June 2004 and February 2012 were reviewed. The relationship between the percentage change in the aortic diameter and the false lumen patency status was assessed by examining the early and late postoperative computed tomography imaging studies. Results: There were two in-hospital mortalities, one late death, and three follow-up loses. The mean follow-up duration for the final 21 patients studied was $54{\pm}19.0$ months (range, 20 to 82 months). The incidence of false lumen thrombosis within 2 weeks of surgery in the proximal, middle, and distal thoracic aorta, and the suprarenal and infrarenal abdominal aorta were 67%, 38%, 38%, 48%, and 33%, respectively, and 57%, 67%, 52%, 33%, and 33% for those examined at a mean of $49{\pm}18$ months after surgery, respectively. The false lumen regressed in 11 patients (42.3%). The aortic diameters were larger in the patients with a patent false lumen than those with a thrombosed false lumen at all levels of the descending aorta (p <0.05). Conclusion: TAR and a more complete primary tear-resection can be accomplished with a relatively low-risk of morbidity and mortality. Enlargement of the distal aorta significantly correlated with the false lumen patency status.

Comparative Evaluation of UAV NIR Imagery versusin-situ Point Photo in Surveying Urban Tributary Vegetation (도심소하천 식생조사에서 현장사진과 UAV 근적외선 영상의 비교평가)

  • Lee, Jung-Joo;Hwang, Young-Seok;Park, Seong-Il;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.475-488
    • /
    • 2018
  • Surveying urban tributary vegetation is based mainly on field sampling at present. The tributary vegetation survey integrating UAV NIR(Unmanned Aerial Vehicle Near Infrared Radiance) imagery and in-situ point photo has received only limited attentions from the field ecologist. The reason for this could be the largely undemonstrated applicability of UAV NIR imagery by the field ecologist as a monitoring tool for urban tributary vegetation. The principal advantage of UAV NIR imagery as a remote sensor is to provide, in a cost-effective manner, information required for a very narrow swath target such as urban tributary (10m width or so), utilizing very low altitude flight, real-time geo-referencing and stereo imaging. An exhaustive and realistic comparison of the two techniques was conducted, based on operational customer requirement of urban tributary vegetation survey: synoptic information, ground detail and quantitative data collection. UAV NIR imagery made it possible to identify area-wide patterns of the major plant communities subject to many different influences (e.g. artificial land use pattern), which cannot be acquired by traditional field sampling. Although field survey has already gained worldwide recognition by plant ecologists as a typical method of urban tributary vegetation monitoring, this approach did not provide a level of information that is either scientifically reliable or economically feasible in terms of urban tributary vegetation (e.g. remedial field works). It is anticipated that this research output could be used as a valuable reference for area-wide information obtained by UAV NIR imagery in urban tributary vegetation survey.

Trend of Multigenerational Transfer and Toxicity Studies Using Nanomaterials (나노물질을 이용한 다세대전이 및 독성 연구 추세)

  • Moon, Jongmin;An, Youn-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.7
    • /
    • pp.395-401
    • /
    • 2016
  • Nano-saftey has become an emerging issue recently, because of the broad use of nanomaterials in nano-industries and commercial areas. For a sustainable development in the nano-industry, active studies on nano-safety should be executed, especially on the potential risks in engineered nanomaterials (ENMs). Although acute and chronic assessments of nanomaterials have been extensively studied in many studies, multigenerational studies are very scarce. Overall, multigenerational studies have progressed as two different trends, studying post-generational effects or trans-generation effects. This study intended to suggest further nano-safety studies based on the trends and limitations of current ones. Through a comparative analysis, we investigated peer-reviewed multigenerational studies that used nanomaterials. Thirteen studies on post-generation effects confirmed generational nano-toxicity via several bioassays, such as mortality, fertility, and behavioral assays. Seven studies on trans-generation effects demonstrated nanomaterial pathways to next generations, using imaging techniques. Until now, mechanisms for post-generational nano-toxicity has been rarely proposed. Thus, we propose that complementary studies on such mechanisms are imperative for future studies.

Studies on North Korean Documentary Films: Structures as to How Meanings of Film Literature are Made (북한 기록영화 연구: 영화문헌의 의미생성 구조)

  • Kim, Seung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.82-89
    • /
    • 2017
  • This paper intends to examine how North Korea has incited and persuaded its people by figuring out the structure regarding the meaning creation of its documentary film "Kim Jong-un, the Respected Comrade Supreme Commander, Giving On-site Guidance on the Grand Project of the People's Army" produced in 2015, which was North Korea's politically important year. The analysis results show that its narrative structure of the film took the form of an introduction, body, and conclusion to substantiate it obviously given theme. Its imaging techniques are geared towards uplifting the public's combat mentality and its sound contributes to achieving their adherence. In this regard, its film literature has the following meaning structure: first, the film takes the form of both film annals and the structure for the public to easily comprehend; second, the film clearly demonstrates its deep-rooted theme asking for the public to follow in the footsteps of the party's late father for its leadership; and third, the film also aims to establish the images of an always awake working leader by implanting and arranging the leader's diligence about his revolutionary activities in the documentary film. North Korea's documentary films serve as a weapon used for instigating revolution and construction. Given this, the producers of all documentary films have made sure to turn film literatures into the film literatures of the great leader. It was identified that under the social vision that the Kim Jong-un regime is a "socialist civilized country", he has tightened his grip on power in North Korea through the propaganda tool of film literatures.