• Title/Summary/Keyword: image geometry

Search Result 534, Processing Time 0.028 seconds

Epipolar Geometry of Alternative Sensor Models for High-Resolution Satellite Imagery (간략모형식의 에피폴라 기하 생성 및 분석)

  • 정원조;김의명;유복모;유환희
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.179-184
    • /
    • 2004
  • High-resolution satellite imagery are used in various application field such as generation of DEM, orthophto, and three dimensional city model. To define the relation between image and object space, sensor modelling and generation of the epipolar image is essential processes. As the header information or physical sensor model becomes unavailable for the end users due to the national security or commercial purpose, generation of epipolar images without these information becomes one of important processes. In this study, epipolar geometry is generated and analysed by applying two generalized sensor models; parallel and parallel-perspective model Epipolar equation of the parallel model has linear property which is relatively simple; Epipolar geometry of the parallel-perspective model is non-linear. This linear property enable us to generate epipolar image efficiently.

  • PDF

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • v.44 no.5
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

Generation of 3 Dimensional Image Model from Multiple Digital Photographs (다중 디지털 사진을 이용한 3차원 이미지 모델 생성)

  • 정태은;석정민;신효철;류재평
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1634-1637
    • /
    • 2003
  • Any given object on the motor-driven turntable is pictured from 8 to 72 different views with a digital camera. 3D shape reconstruction is performed with the integrated software called by Scanware from these multiple digital photographs. There are several steps such as configuration, calibration, capturing, segmentation, shape creation, texturing and merging process during the shape reconstruction process. 3D geometry data can be exported to cad data such as Autocad input file. Also 3D image model is generated from 3D geometry and texture data, and is used to advertise the model in the internet environment. Consumers can see the object realistically from wanted views by rotating or zooming in the internet browsers with Scanbull spx plug-in. The spx format allows a compact saving of 3D objects to handle or download. There are many types of scan equipments such as laser scanners and photogrammetric scanners. Line or point scan methods by laser can generate precise 3D geometry but cannot obtain color textures in general. Reversely, 3D image modeling with photogrammetry can generate not only geometries but also textures from associated polygons. We got various 3D image models and introduced the process of getting 3D image model of an internet-connected watchdog robot.

  • PDF

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

Image Resampling for Epipolar Geometry in Digital Photogrammetry (數値寫眞測量에 있어서 epipolar 幾何狀態를 形成하기 위한 映像再配列)

  • Yeu, Bock-Mo;Youn, Kyung-Chul;Jeong, Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.10 no.2
    • /
    • pp.25-30
    • /
    • 1992
  • Most algorithms in computer vision and digital photogrammetry assume that digital stereo pairs are registered in epipolar geometry. But, an aerial stereo pair is not likely to be in epiplar geometry since the attitude of the camera at the instant of exposure is different at every exposure station. In this paper, stereo digital imagery is obtained from aerial stereo pair by scanner. Then procesure to resample the digital imagery to epipolar geometry using exterior orientation elements after absolute orientation is described. As a result, a stereo imagery in epipolar geometry is produced from stereo digital imagery. Epipolar imagery in this paper is applied to the image matching method by digital image correlation technique. Then, a digital elevation model is produced from the result of image matching. The digital elevation model in this paper is compared to the other digital elevation model produced by analytical plotter. As a result, an economical method to generate digital elevation model is presented.

  • PDF

Preprocessing Method for Efficient Compression of Patch-based Image (패치 영상의 효율적 압축을 위한 전처리 방법)

  • Lee, Sin-Wook;Lee, Sun-Young;Chang, Eun-Youn;Hur, Nam-Ho;Jang, Euee-S.
    • Journal of Broadcast Engineering
    • /
    • v.13 no.1
    • /
    • pp.109-118
    • /
    • 2008
  • In mapping a texture image into a 3D mesh model for photo-realistic graphic applications, the compression of texture image is as important as geometry of 3D mesh. Typically, the size of the (compressed) texture image of 3D model is comparable to that of the (compressed) 3D mesh geometry. Most 3D model compression techniques are to compress the 3D mesh geometry, rather than to compress the texture image. Well-known image compression standards (i.e., JPEG) have been extensively used for texture image compression. However, such techniques are not so efficient when it comes to compress an image with texture patches, since the patches are little correlated. In this paper, we proposed a preprocessing method to substantially improve the compression efficiency of texture compression. From the experimental results, the proposed method was shown to be efficient in compression with a bit-saving from 23% to 45%.

S/W Cinderella for Student's mental Representation about Non-Euclidean Geometry (비유클리드 기하의 정신적 표상을 위한 S/W Cinderella)

  • Kye Younghee;Shin Kyunghee
    • The Mathematical Education
    • /
    • v.44 no.2 s.109
    • /
    • pp.297-306
    • /
    • 2005
  • In this paper, we propose a computer environment class for student's mental representations about non-Euclidean geometry. Through the software Cinderella, students construct knowledge about non-Euclidean geometry and recognize differentness between Euclidean and non-Euclidean geometry. Also they recognize an existence of non-Euclidean geometry newly and its mental representations with images represented in Cinderella. In geometry class, we make students can use many representations systematically and can figure a visual internal image by emphasizing a transform process. And then students can reason about non-Euclidean geometry.

  • PDF

Haptic Interaction with Objects Displayed in a Picture based on Surface Normal Estimation (사진 속 피사체의 법선 벡터 예측에 기반한 햅틱 상호 작용)

  • Kim, Seung-Chan;Kwon, Dong-Soo
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.3
    • /
    • pp.179-185
    • /
    • 2013
  • In this paper we propose a haptic interaction system that physically represents the underlying geometry of objects displayed in a 2D picture, i.e., a digital image. To obtain the object's geometry displayed in the picture, we estimate the physical transformation between the object plane and the image plane based on homographic information. We then calculate the rotated surface normal vector of the object's face and place it on the corresponding part in the 2D image. The purpose of this setup is to create a force that can be rendered along with the image without distorting the visual information. We evaluated the proposed haptic rendering system using a set of pictures of objects with different orientations. The experimental results show that the participants reliably identified the geometric configuration by touching the object in the picture. We conclude this paper with a set of applications.

High-Speed Image Matching Method Using Geometry - Phase Information (기하 위상 정보를 이용한 고속 영상 정합 기법)

  • Chong Min-Yeong;Oh Jae-Yong;Lee Chil-Woo;Bae Ki-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.9
    • /
    • pp.1195-1207
    • /
    • 2005
  • In this paper, we describe image matching techniques which is automatically retrieving the exact matching area using geometry-phase information. We proposed a Matching Method which is rapidly estimating the correspondent points between adjacent images that included big-rotation and top-bottom movement element. It is a method that reduce computation quantity to be required to find an exact correspondent position using geometry-phase information of extracted points in images and DT map which set the distance value among feature points and other points on the basis of each feature point of a image. The proposed method shows good performance especially in the part to search a exact correspondent position between adjacent images that included big-rotation and top-bottom movement element.

  • PDF

Sub-Pixel Analysis of Hyperspectral Image Using Linear Spectral Mixing Model and Convex Geometry Concept

  • Kim, Dae-Sung;Kim, Yong-Il;Lim, Young-Jae
    • Korean Journal of Geomatics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • In the middle-resolution remote sensing, the Ground Sampled Distance (GSD) that the detector senses and samples is generally larger than the actual size of the objects (or materials) of interest, and so several objects are embedded in a single pixel. In this case, as it is impossible to detect these objects by the conventional spatial-based image processing techniques, it has to be carried out at sub-pixel level through spectral properties. In this paper, we explain the sub-pixel analysis algorithm, also known as the Linear Spectral Mixing (LSM) model, which has been experimented using the Hyperion data. To find Endmembers used as the prior knowledge for LSM model, we applied the concept of the convex geometry on the two-dimensional scatter plot. The Atmospheric Correction and Minimum Noise Fraction techniques are presented for the pre-processing of Hyperion data. As LSM model is the simplest approach in sub-pixel analysis, the results of our experiment is not good. But we intend to say that the sub-pixel analysis shows much more information in comparison with the image classification.

  • PDF