Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System  

An, Hyeon (부산가톨릭대학교 대학원 방사선학과)
Kim, Changsoo (부산가톨릭대학교 보건과학대학 방사선학과)
Kim, Jung-Hoon (부산가톨릭대학교 보건과학대학 방사선학과)
Publication Information
Abstract
The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.
Keywords
IEC Radiation Quality; MTF; NPS;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 M. Strotzer, J. Gmeinwieser, M. Spahn, M. Volk, R. Frund, J. Seitz, V. Spies, J. Alexander, and S. Feuerbach, "Amorphous silicon flat-panel X-ray Detector versus screen-film Radiography Effect of dose reduction on the Detectability of cortical bone defects and Fractures," Invest in Radiology's Future, Vol.33, No.1, pp.33-38, 1998.
2 김창수, 고성진, 강세식, "디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가", 한국콘텐츠학회논문지, 제10권, 제6호, pp.329-335, 2010.   DOI
3 이대형, DR Detector 의 Raw Data 분석을 통한 NPS, MTF, DQE 측정과 성능평가연구, 고려대학교 의용과학대학원, 석사논문, pp.15-29, 2008.
4 IEC62220-1: Medical Electrical Equipment Characteristics of Digital X-Ray Imaging Devices - Part 1, Determination of the Detective Quantum Efficiency, 2003.
5 J. Rowlands and S. Kasap, "Amorphous semiconductors Usher in digital x-ray imaging," Physics Today, Vol.50, No.11, pp.24-30, 1997.   DOI
6 R. A. Street, S. Nelson, L. Antonuk, and V. Perez Mendez, "Amorphous silicon sensor arrays for radiation imaging," Proceeding Materials Reserch Socitey, Vol.192, pp.441-452, 1990.
7 E. Samei, N. T. Ranger, J. T. Dobbins III, and Y. Chen, "Intercomparison of methods for image quality characterization: I. modulation transfer function," Medical Physics, Vol.33, No.5, pp.1454-1465, 2006.   DOI   ScienceOn
8 J. T. Dobbins III, E. Samei, N. T. Ranger, and Y. Chen, "Intercomparison of methods for image quality characterization. II. noise power spectrum," Medical Physics, Vol.33, No.5, pp.1466-1475, 2006.   DOI   ScienceOn
9 J. T. Dobbins III, D. L. Ergun, L. Rutz, D. A. Hinshaw, H. Blume, and D. C. Clark, "DQE (f) of four generations of computed radiography acquisition devices," Medical Physics, Vol.22, No.10, pp.1581-1593, 1995.   DOI   ScienceOn
10 양한준, CMOS 영상센서를 이용한 디지털 엑스선 영상의 특성평가에 관한 연구, 명지대학교 대학원, 박사학위논문, 2008.
11 IEC 61267 "Medical diagnostic X-ray Equipment Radiation Conditions for use in the Determination of Characteristics," 2005.
12 Jerold T. Bushberg, The Essential physics of Medical imaging 3rd Ed., pp.70-95, LIPPINCOTT WILLIAMS & WILKINS, 2012.
13 김창복, "CR을 이용한 일반촬영장치의 MTF 측정", 한국방사선기술연구회지, 제28권, 제1호, pp.111-115, 2005
14 신동규, 평판 X선 영상 시스템 개발에 관한 연구, 연세대학교 대학원, 박사학위논문, 2005.
15 정회원, 민정환, 김정민, 박민석, 이광용, "CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가", 방사선 기술과학, Vol.35, No.2, pp.108-116, 2012.