• Title/Summary/Keyword: hold time

Search Result 623, Processing Time 0.027 seconds

Time-Discretization of Nonlinear Systems with Delayed Multi-Input Using Taylor Series

  • Park, Ji-Hyang;Chong, Kil-To;Nikolaos Kazantzis;Alexander G. Parlos
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1107-1120
    • /
    • 2004
  • This study proposes a new scheme for the sampled-data representation of nonlinear systems with time-delayed multi-input. The proposed scheme is based on the Taylor-series expansion and zero-order hold assumption. The mathematical structure of a new discretization scheme is explored. On the basis of this structure, the sampled-data representation of nonlinear systems including time-delay is derived. The new scheme is applied to nonlinear systems with two inputs and then the delayed multi-input general equation is derived. The resulting time-discretization provides a finite-dimensional representation of nonlinear control systems with time-delay enabling existing controller design techniques to be applied to them. In order to evaluate the tracking performance of the proposed scheme, an algorithm is tested for some of the examples including maneuvering of an automobile and a 2-DOF mechanical system.

Time-Discretization of Non-Affine Nonlinear System with Delayed Input Using Taylor-Series

  • Park, Ji-Hyang;Chong, Kil-To;Kazantzis, Nikolaos;Parlos, Alexander G.
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.8
    • /
    • pp.1297-1305
    • /
    • 2004
  • In this paper, we propose a new scheme for the discretization of nonlinear systems using Taylor series expansion and the zero-order hold assumption. This scheme is applied to the sampled-data representation of a non-affine nonlinear system with constant input time-delay. The mathematical expressions of the discretization scheme are presented and the ability of the algorithm is tested for some of the examples. The proposed scheme provides a finite-dimensional representation for nonlinear systems with time-delay enabling existing controller design techniques to be applied to them. For all the case studies, various sampling rates and time-delay values are considered.

Time-Discretization of Nonlinear control systems with State-delay via Taylor-Lie Series (Taylor-Lei Series에 의한 지연이 있는 비선형 시스템의 시간 이산화)

  • Zhang, Yuanliang;Lee, Yi-Dong;Chong, Kil-To
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, we propose a new scheme for the discretization of nonlinear systems using Taylor series expansion and the zero-order hold assumption. This scheme is applied to the sample-data representation of a nonlinear system with constant state tine-delay. The mathematical expressions of the discretization scheme are presented and the effect of the time-discretization method on key properties of nonlinear control system with state tine-delay, such as equilibrium properties and asymptotic ability, is examined. The proposed scheme provides a finite-dimensional representation for nonlinear systems with state time-delay enabling existing controller design techniques to be applied to then. The performance of the proposed discretization procedure is evaluated using a nonlinear system. For this nonlinear system, various sampling rates and time-delay values are considered.

  • PDF

Analysis of a network for control systems in nuclear power plants and a case study (원자력 발전소 제어계통을 위한 네트워크의 해석과 사례 연구)

  • Lee, Sung-Woo;Yim, Han-Suck
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.734-743
    • /
    • 1999
  • In this paper, a real-time communication method using a PICNET-NP(Plant instrumentation and Control Network for Nuclear Power plant) is proposed with an analysis of the control network requirements of DCS(Distributed Control System) in nuclear power plants. The method satisfies deadline in case of worst data traffics by considering aperiodic and periodic real-time data and others. In addition, the method was used to analyze the data characteristics of the DCS in existing nuclear power plant. The result shows that use of this method meets the response time requirement(100ms).

  • PDF

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD

  • Han, J.M.;Bae, K.W.;Kim, S.Y.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.694-697
    • /
    • 2003
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by adjusting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by blinking drive. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

  • PDF

Real-Time Optimal Control for Nonlinear Dynamical Systems Based on Fuzzy Cell Mapping

  • Park, H.T.;Kim, H.D.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.388-388
    • /
    • 2000
  • The complexity of nonlinear systems makes it difficult to ascertain their behavior using classical methods of analysis. Many efforts have been focused on the advanced algorithms and techniques that hold the promise of improving real-time optimal control while at the same time providing higher accuracy. In this paper, a fuzzy cell mapping method of real-time optimal control far nonlinear dynamical systems is proposed. This approach combines fuzzy logic with cell mapping techniques in order to find the optimal input level and optimal time interval in the finite set which change the state of a system to achieve a desired obiective. In order to illustrate this method, we analyze the behavior of an inverted pendulum using fuzzy cell mapping.

  • PDF

Joining of Polymer Materials with Ultrasonic Welding (초음파 용접을 이용한 합성수지의 결합)

  • 이철구;정규창
    • Journal of Welding and Joining
    • /
    • v.16 no.2
    • /
    • pp.48-56
    • /
    • 1998
  • This study was performed to find the best bonding conditions by comparing mechanical properties in thermoplastic resin of polyethylene (PE) and polyamide (PA) adhesion. Following results were obtained from the tests with varying welding time and welding pressure. Satisfactory adhesion was executed in ultrasonic welding for the same materials of PE and PA. The best welding conditions were found to be welding time of 1 second, welding pressure of 250kPa for PE-PE weding, 2 second and 350kPa for PA-PA welding. Welding time and welding pressure end to increase with the increase of materials strength. Dissimilar materials were adhered when adhesion and ultrasonc welding were performed simultaneously. The observation of the structure of ultrasonic welding area with microscope showed differenticated structures between well adhered region and badly adhered region.

  • PDF

Quasi-breath-hold (QBH) Biofeedback in Gated 3D Thoracic MRI: Feasibility Study (게이트 흉부자기 공명 영상법과 함께 사용할 수 있는 의사호흡정지(QBH) 바이오 피드백)

  • Kim, Taeho;Pooley, Robert;Lee, Danny;Keall, Paul;Lee, Rena;Kim, Siyong
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • The aim of the study is to test a hypothesis that quasi-breath-hold (QBH) biofeedback improves the residual respiratory motion management in gated 3D thoracic MR imaging, reducing respiratory motion artifacts with insignificant acquisition time alteration. To test the hypothesis five healthy human subjects underwent two gated MR imaging studies based on a T2 weighted SPACE MR pulse sequence using a respiratory navigator of a 3T Siemens MRI: one under free breathing and the other under QBH biofeedback breathing. The QBH biofeedback system utilized the external marker position on the abdomen obtained with an RPM system (Real-time Position Management, Varian) to audio-visually guide a human subject for 2s breath-hold at 90% exhalation position in each respiratory cycle. The improvement in the upper liver breath-hold motion reproducibility within the gating window using the QBH biofeedback system has been assessed for a group of volunteers. We assessed the residual respiratory motion management within the gating window and respiratory motion artifacts in 3D thoracic MRI both with/without QBH biofeedback. In addition, the RMSE (root mean square error) of abdominal displacement has been investigated. The QBH biofeedback reduced the residual upper liver motion within the gating window during MR acquisitions (~6 minutes) compared to that for free breathing, resulting in the reduction of respiratory motion artifacts in lung and liver of gated 3D thoracic MR images. The abdominal motion reduction in the gated window was consistent with the residual motion reduction of the diaphragm with QBH biofeedback. Consequently, average RMSE (root mean square error) of abdominal displacement obtained from the RPM has been also reduced from 2.0 mm of free breathing to 0.7 mm of QBH biofeedback breathing over the entire cycle (67% reduction, p-value=0.02) and from 1.7 mm of free breathing to 0.7 mm of QBH biofeedback breathing in the gated window (58% reduction, p-value=0.14). The average baseline drift obtained using a linear fit was reduced from 5.5 mm/min with free breathing to 0.6 mm/min (89% reduction, p-value=0.017) with QBH biofeedback. The study demonstrated that the QBH biofeedback improved the upper liver breath-hold motion reproducibility during the gated 3D thoracic MR imaging. This system can provide clinically applicable motion management of the internal anatomy for gated medical imaging as well as gated radiotherapy.

A Study on Properties of Patents in the Applicants and Possibility of Economical Usage-Focused on Pharmaceutical Chemistry Industry Sector (기업의 보유 특허 특성과 경제적 활용 가능성에 대한 연구-의료화학산업 특허를 중심으로)

  • Ko, Young-Hee;Lee, Mi-Hyun
    • Knowledge Management Research
    • /
    • v.14 no.1
    • /
    • pp.39-55
    • /
    • 2013
  • As the importance of intellectual property rights for the 21st century challenge became prominent, many companies have been trying to secure many rights competitively. In particular, application numbers of patent that represents technology has been increased continuously. Korean companies were not exception; mainly in large companies, there have been continued the efforts to grow the number of patent applications in quantitative volume. But the issues that how viable patents the companies have, how effectively the companies manage, and how economically usable the patents are, are totally different from quantitative management level. As such, the issue is connected to how to assess the patent management level of companies. On the other side of quantitative growth of patent that companies hold, there are some problems such as the difficulties to determine if the patents hold substantial values, and the difficulties to determine whether the patent are managed effectively. In addition, as the numbers of patent application and registration of companies are increased, the cost for patent holding and managing increase. It is required to pay continuous attention to the cost of patent management because patent registration fee has a property that increases rapidly with time and burden for patentee become heavier. As a result of analysis and interpretation, we confirmed that quantitative management, particularly the number of patent applicant does not make positive impact on how to use patent after application. Rather, it is observed that the economical usage is influenced positively by the efforts of patent applicants such as considering for the time of patent examination, paying attention to receive patent registration decision. Therefore, this study shows that efforts patent applicants provide in management level after application time are important to maintain the value of patents.

  • PDF

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.