• 제목/요약/키워드: high linearity

검색결과 1,062건 처리시간 0.027초

Multiple Gated Transistors의 Derivative Superposition Method를 이용한 CMOS Low Noise Amplifier의 선형성 개선 (Improving the Linearity of CMOS Low Noise Amplifier Using Multiple Gated Transistors)

  • 양진호;김희중;박창준;최진성;윤제형;김범만
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.505-506
    • /
    • 2006
  • In this paper, the linearization technique for CMOS low-noise amplifier (LNA) using the derivative superposition method through the multiple gated transistors configuration is presented. LNA based on 0.13um RF CMOS process has been implemented with a modified cascode configuration using multiple gated common source transistors to fulfill a high linearity. Compared with a conventional cascode type LNA, the third order input intercept point (IIP3) per DC power consumption (IIP3/DC) is improved by 3.85 dB. The LNA achieved 2.5-dBm IIP3 with 13.4-dB gain, 3.6 dB NF at 2.4 GHz consuming 8.56 mA from a 1.5-V supply.

  • PDF

위사번수와 조직이 면직물의 역학특성 및 태에 미치는 영향 (Influence of Weft's Cotton Count & Weave Construction on the Mechanical Properties & Hand of Cotton Woven Fabrics)

  • 배진화;박정환;안승국
    • 한국의류산업학회지
    • /
    • 제7권5호
    • /
    • pp.553-559
    • /
    • 2005
  • Hand characteristics related with structural properties of fabrics have something to do with mechanical properties of fabric. In this study, the mechanical properties and hand characteristics have been analyzed according to fabric structural parameters such as the weave structure and the linear density of weft of cotton fabric. Mechanical properties have been used by KES-FB system which measures hand characteristics and mechanical properties of fabric. Linear density of weft, tensile, bending, and shear properties are decreasing with increasing weft linear density, and there is no considerable effects on compression and surface properties. In case of formability with weft linear density, B/W, 2HG/G, 2HB/B, 2HB/W, $\sqrt[3]{B/W}$, $\sqrt{2HB/W}$, W/T except MMD/SMD, WC/T, and WC/W have been effected. There is a high correlation between the crimp, tightness, hand, formability and mechanical properties specially tensile linearity, bending, shear, and compression properties. The weft crimp influences the bending rigidity, shear properties, and the tightness which have effects on the tensile linearity, bending, shear, compression properties, hand, and formability.

비선형모델을 이용한 matrix convertor로 구동되는 축소차원 확장 루엔버거 관측기기반의 유도전동기 센서리스 벡터제어의 성능개선 (Performance Improvement of Reduced Order Extended Luenberger Observer(ROELO) based Sensorless Vector Control Fed by Matrix Converter With Non-linearity Modeling)

  • 이교범
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.363-372
    • /
    • 2005
  • 본 논문에서는 비선형 모델링 기법을 이용하여 matrix convertor로 구동되는 유도전동기 구동장치의 성능개선을 위한 새로운 센서리스 기법을 제안한다. 각 스위치에서 발생하는 전환지연과 스위치 소자의 전압강하등과 같은 matrix converter의 비선형 특성을 모델링하여 보상함으로써 저속영역에서의 속도제어성능을 향상시킨다. 전속도 영역에서의 속도 센서리스 제어성능을 향상시키기 위해 축소차원 확장 루엔버거 관측기를 적용하고, 제안한 관측기 이득의 설정방법을 제안한다. 실험을 통해 제안한 제어 알고리즘의 타당성을 검증한다

Validation and measurement uncertainty of HPLC-UV method for quercetin quantification in various foods

  • Seo, Eunbin;Lim, Suji;Yun, Choong-In;Shin, Jae-Wook;Kim, Young-Jun
    • 한국식품과학회지
    • /
    • 제53권6호
    • /
    • pp.682-687
    • /
    • 2021
  • The purpose of this study was to validate a high-performance liquid chromatography (HPLC) method for the quantitative analysis of quercetin in various foods. The method was based on HPLC-UV (360 nm). The method was validated using candy, beverage, and sausage which were tested for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. Matrix-matched calibration was also applied. The calibration curves (0.5-50 mg/L) showed good linearity (r2≥0.9998). LOD and LOQ ranged from 0.15 to 0.31 mg/kg and from 0.44 to 0.93 mg/kg, respectively. The average accuracy and precision at 0.5, 2.5, and 10 mg/kg ranged from 84.3 to 102.0% and 0.7 to 3.0 relative standard deviation (RSD%), respectively. This study confirmed the applicability of the proposed method by applying it to commercial products, such as teas and beverages. Thus, the proposed analytical method is suitable for quantifying quercetin in various foods.

Analytical Method Validation of (-)Epicatechin gallate in Penthorum chinense Pursh Extract using HPLC

  • Kwon, Jin Gwan;Jung, Yeon Woo;Seo, Changon;Hong, Seong Su;Lee, Ji Eun;Shin, Hyun Tak;Jung, Su Young;Choi, Chun Whan;Kim, Jin Kyu
    • 한국자원식물학회:학술대회논문집
    • /
    • 한국자원식물학회 2019년도 춘계학술대회
    • /
    • pp.100-100
    • /
    • 2019
  • This study attempted to establish a High Performance Liquid Chromatography (HPLC) analysis method for the determination of (-)-epicatechin gallate as a part of the quality control for the development of functional cosmetic materials from Penthorum chinense Pursh extracts. HPLC was performed on a Unison US-C18 column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.05% (v/v) trifluoroacetic acid (TFA) and methyl alcohol at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 280 nm. The HPLC method was performed in accordance with the International Conference on Harmonization (ICH) guideline (version 4, 2005) of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation were 0.11 and 0.33 mg/mL, respectively. Calibration curves showed good linearity (r2 > 0.9999), and the precision of analysis was satisfied (less than 0.6%). Recoveries of quantified compounds ranged from 99.51 to 101.92%. This result indicates that the established HPLC method is very useful for the determination of marker compound in P. chinense Pursh extracts.

  • PDF

왕벚나무 껍질로부터 Naringenin, Sakuranetin, Prunetin의 분리 및 함량 분석 (Isolation and Quantitative Analysis of Naringenin, Sakuranetin and Prunetin from the Barks of Prunus yedoensis)

  • 김은남;김성철;정길생
    • 생약학회지
    • /
    • 제50권3호
    • /
    • pp.226-231
    • /
    • 2019
  • Prunus yedoensis Matsum. (Rosaceae) has been used for cough, urticaria, pruritus, dermatitis, asthma and relaxation in traditional Korean medicine. In this study, naringenin, sakuranetin and prunetin were isolated from the barks of P. yedoensis and quantification were performed by using high performance liquid chromatography (HPLC) method with diode array detector. The structures of naringenin and sakuranetin, prunetin were identified NMR spectroscopic data analysis. The content of each compound was analyzed by HPLC and the analytical method was validated through linearity, precision, accuracy and specificity test. The result showed that calibration curves of three compounds naringenin, sakuranetin and prunetin indicated great linearity with a correlation coefficient ($R^2$) of 1.00, 1.00 and 0.99. Intra and inter day measurement accuracy of the three compounds ranged from 92.70 ~ 112.70%, and showed precision was less than 3%. Therefore, the content analysis showed that naringenin ($0.132{\pm}0.016%$), sakuranetin ($0.108{\pm}0.023%$), and prunetin ($0.059{\pm}0.014%$).

꾸지뽕나무 뿌리로부터 Cudratricusxanthone A와 Cudraxanthone D의 분리 및 함량 분석 (Isolation and Quantitative Analysis of Cudratricusxanthone A and Cudraxanthone D from Roots of Cudrania tricuspidata Bureau)

  • 박수연;김은남;정길생
    • 생약학회지
    • /
    • 제50권1호
    • /
    • pp.59-64
    • /
    • 2019
  • Cudrania tricuspidata Bureau (Moraceae) has been used for physical weakness, impotence and insomnia in traditional Korean medicine. In this study, cudratricusxanthone A and cudraxanthone D were isolated from roots of C. tricuspidata and quantification were achieved by using high performance liquid chromatography (HPLC) method with diode array detector. The isolated compound was identified by NMR analysis and HPLC method was validated by linearity, precision and specificity test. The results showed that calibration curves of two compounds indicated great linearity with a correlation coefficient ($R^2$) of 0.9976 and 0.9995. The limits of detection (LOD) for cudratricusxanthone A and cudraxanthone D were 1.15, $0.11{\mu}g/ml$. Intra-day precision of cudratricusxanthone A and cudraxanthone D were 0.32~1.99%, 0.09~3.32% and inter-day precision were 0.59~2.40%, 0.28~1.55% RSD (%) values, respectively. The specificity was confirmed by chromatograph and quantitative contents of cudratricusxanthone A and cudraxanthone D were $0.46{\pm}0.02%$ and $1.53{\pm}0.06%$. Therefore, this study can be used as a basic research data for the quantitative analysis of derived compounds from roots of C. tricuspidata.

LC-MS/MS를 이용한 반려동물 사료에서 곰팡이독소 동시분석법 유효성 확인 (Validation of simultaneous mycotoxin analysis method in pet food using LC-MS/MS)

  • 최윤화;안우석;김지은;김두환
    • 한국동물위생학회지
    • /
    • 제45권3호
    • /
    • pp.237-242
    • /
    • 2022
  • The simultaneous analysis of mycotoxins using LC-MS/MS, a food official analysis method, was applied with compound feed for pets with high consumer preferences. In this study, the linearity of all calibration curves showed good linearity of 0.99 or more. and both the accuracy (recovery rate) and precision (repeatability) criteria of the concentration range for each mycotoxin in the National Agricultural Products Quality Management Service's Validation and Verification Guidelines were met. And as a result of analyzing FAPAS QCM in the same way, it was assesed that the z-scores of Aflatoxin B1, Ochratoxin A, Zearalenone, and Fumonisin B1, were within ±2 range. This study showed that the application of the food official analysis method to compound feed for pets is suitable.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • 분석과학
    • /
    • 제36권2호
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

Humidity and Temperature Response Characteristics of Optical Fiber Dislocation Fusion Sensor Coated with Graphene Quantum Dots

  • Dailin Li;Xiaodan Yu;Ning Wang;Wenting Liu;Shiqi Liu;Liang Xu;Dong Fang;Huapeng Yu
    • Current Optics and Photonics
    • /
    • 제7권5호
    • /
    • pp.504-510
    • /
    • 2023
  • An optical fiber dislocation fusion humidity sensor coated with graphene quantum dots is investigated. A Mach-Zehnder interferometer is fabricated with three dislocated single-mode fibers with graphene quantum dots coating humidity-sensitive materials. Humidity response experiments showed a good linear response and high sensitivity with easy fabrication and low-cost materials. From 22% to 98% RH, the humidity response sensitivity of the sensor is 0.24 dB/% RH, with 0.9825 linearity. To investigate the cross-response of humidity and temperature, temperature response experiments are conducted. From 30 ℃ to 70 ℃, the results showed 0.02 dB/℃ sensitivity and 0.9824 linearity. The humidity response experimental curve is compared with the temperature experimental curve. The big difference between humidity sensitivity and temperature sensitivity is very helpful to solve the cross-response of humidity and temperature. The influence of temperature fluctuations in humidity measurements is not obvious.