• Title/Summary/Keyword: harmonics

Search Result 2,110, Processing Time 0.024 seconds

Characteristics on the Harmonic Sensitivity of an Induction Watthour Meter (유도형 적산전력량계의 고조파 민감도 특성)

  • Jang, Seok-Myeong;Lee, Seong-Ho;Park, Yeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.587-596
    • /
    • 1999
  • The use of Switching elements in power systems causes the current or voltage to involve harmonic waves. Harmonics bring about registration errors of the equipment for measuring power. In case the induction watthour meter designed on sinusoidal source is used in the measurement of power with harmonics, the precise measurement of power has many problems because harmonics cause a decrease of power factor and vibration by the unstable driving force on the aluminum disc. In this paper, analysis and test results on the harmonic sensitivity of an induction watthour meter is reported when the input voltage and current with harmonics were supplied to single-phase watthour meter.

  • PDF

An Applicability of Teager Energy Operator and Energy Separation Algorithm for Waveform Distortion Analysis : Harmonics, Inter-harmonics and Frequency Variation

  • Cho, Soo-Hwan;Hur, Jin;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1210-1216
    • /
    • 2014
  • This paper deals with an application of Teager Energy Operator (TEO) and Energy Separation Algorithm(ESA) to detect and determine various voltage waveform distortions like harmonics, inter-harmonics and frequency variation. Because the TEO and DESA algorithm was initially proposed for speech or communication analysis, its applications are limited to some types of waveform in the power quality analysis area. For example, an undistorted voltage signal is similar with a pure sinusoid. A voltage fluctuation is very similar with an amplitude-modulated signal, from the viewpoint of signal theory. And a continuous frequency variation is similar with a frequency-modulated signal, which is also known as a chirp signal. This paper is written to show that the TEO and DESA algorithm can be used for detecting occurrences of the representative waveform distortions and determining their instantaneous information of amplitude and frequency.

Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement (누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향)

  • Kil, Gyung-Suk;Han, Joo-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

Influence of Torque Ripple Caused by Current Harmonics on Induction Motor Fed PWM Inverter (PWM 인버터로 구동되는 유도전동기 시스템에서 고조파가 토오크 맥동에 미치는 영향에 관한 연구)

  • Baek, S.H.;Kim, Y.;Ham, J.G.;Maeng, I.J.;Sohn, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.12-14
    • /
    • 1995
  • It is necessary to analyze exactly the torque ripple components in the harmonics as to decrease the torque ripple. Lower harmonics influence mainly on torque ripple. Among the harmonics, the pairs of 5's, 7's and 11's, 13's are dominant, and the magnitude of each pairs of current harmonics are very significant. Therefore, for decreasing the torque ripple, current harmonic pairs of 6n ${\pm}$1's orders must be simultaneously eliminated. In the case of eliminating one of current harmonic pairs, even though the magnitude of the current harmonics is small, It has great effect on torque ripple.

  • PDF

Harmonics Measurement and Analysis on Industrial load Facilities (산업용 부하설비의 고조파 측정 및 분석)

  • Han, Wun-Dong;Ji, Pyeong-Shik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • Harmonics happened due to nonlinear systems such as UPS, SCR controlled motors, and fluorescent lighting in distribute power system is very important subject to optimal operation and control of power system. Harmonics sometimes make incorrect operation of protective relaying system under normal condition on power system. In this study, total harmonics distortion(THD) of power were measured and analyzed by the field test on electrical facilities which were installed at the rural industrial complex in Chungbuk province. In addition, the deprivation of power factor by harmonics and the content of THD which is measured at neutral line was researched.

  • PDF

The Trend of suppression technology of harmonics for distribution system (고조파 유출 억제기술의 동향)

  • Koh Hee Seog;Lee Hyun Moo;Lee Chung Sik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.330-332
    • /
    • 2004
  • Reliance on electric power has increased together with customer's demand for delightful and convenient linging. Recently, as appeared in the rapid growth of the technology of power electronics, the installation and apparatus using semiconductor applicotion is widly supplied and used from a household goods to industrial goods. However, these machine generate harmonics current and voltage for electric power system. The harmonics current is increased voltage distortion and generate a lot of interference in the electric power system. In this paper, the trend of the trend of suppression technology of harmonics outflow and the fundamental theory about the suppression of harmonics current in the distribution system are investigated and evaluated Therefore we look forward to supply electric power of good quality to satisfy the harmonics current guide line which is applied to household goods in the world.

  • PDF

Elimination of Low Order Harmonics in Multilevel Inverters Using Genetic Algorithm

  • Salehi, Reza;Farokhnia, Naeem;Abedi, Mehrdad;Fathi, Seyed Hamid
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.132-139
    • /
    • 2011
  • The selective harmonic elimination pulse width modulation (SHEPWM) switching strategy has been applied to multilevel inverters to remove low harmonics. Naturally, the related equations do not have feasible solutions for some operating points associated with the modulation index (M). However, with these infeasible points, minimizing instead of eliminating harmonics is performed. Thus, harmful harmonics such as the $5^{th}$ harmonic still remains in the output waveform. Therefore, it is proposed in this paper to ignore solving the equation associated with the highest order harmonics. A reduction in the eliminated harmonics results in an increase in the degrees of freedom. As a result, the lower order harmonics are eliminated in more operating points. A 9-level inverter is chosen as a case study. The genetic algorithm (GA) for optimization purposes is used. Simulation results verify the proposed method.

Measurement of Saturation Magnetostriction by the Second-order Higher Harmonics of ac Perturbing Magnetic Field (교류 섭동 자기장의 제 2차 고조파를 이용한 포화자기변헝 측정)

  • Cha, S.Y.;Kim, J.K.;Ryu, K.S.;Cho, Y.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2005
  • The profiles of the second-order higher harmonics during B-H hysteresis loop have been measured as functions of the tensile stress in grain-oriented $3.2{\%}$ Si steels. The observed harmonics profiles have been analyzed in terms of the nonlinear, asymmetric magnetization which reflects the domain reorientation under the field. The field interval of the second-order higher harmonics is related to the nucleation and annihilation fields and a measurement method for the magnetostriction is proposed using the harmonics profiles under tensile stress.

Effect of Harmonics on Residual Current Protective Devices (고조파가 누전차단기에 미치는 영향)

  • Jeon, Jeong-Chay;Lee, Sang-Ick;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.84-89
    • /
    • 2006
  • Tripping of residual current protective devices(RCPDs) caused by harmonics has been continuously reported, but no literature is available on the behavior of RCPDs caused by harmonics. This paper, in order to find out the effects of harmonics on RCPDs, investigated the present condition on malfunction of RCPDs and measured harmonics at buildings where nuisance tripping of RCPDs was often occurred. Also, the operational characteristics of RCPDs were tested by the harmonics synthesizer that can generate distorted waveform. Results of experiment detected that there was minimum tripping current of RCPDs when third harmonic added to the fundamental frequency. And it was found that the leakage current to cause tripping of RCPDs increased with more higher order harmonics added to the fundamental frequency.

The Countermeasure about Harmonics of the High Voltage Power Facilities (고압수전설비의 고조파에 관한 대책)

  • Kim, Ju-Chan;Sin, Su-Han;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF