• 제목/요약/키워드: harmonic lock

검색결과 28건 처리시간 0.029초

A Reset-Free Anti-Harmonic Programmable MDLL-Based Frequency Multiplier

  • Park, Geontae;Kim, Hyungtak;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권5호
    • /
    • pp.459-464
    • /
    • 2013
  • A reset-free anti-harmonic programmable multiplying delay-locked loop (MDLL) that provides flexible integer clock multiplication for high performance clocking applications is presented. The proposed MDLL removes harmonic locking problems by utilizing a simple harmonic lock detector and control logic, which allows this MDLL to change the input clock frequency and multiplication factor during operation without the use of start-up circuitry and external reset. A programmable voltage controlled delay line (VCDL) is utilized to achieve a wide operating frequency range from 80 MHz to 1.2 GHz with a multiplication factor of 4, 5, 8, 10, 16 and 20. This MDLL achieves a measured peak-to-peak jitter of 20 ps at 1.2 GHz.

계통연계 인버터를 위한 새로운 고조파 보상법 (A Novel Harmonic Compensation Technique for the Grid-Connected Inverters)

  • Ashraf, Muhammad Noman;Khan, Reyyan Ahmad;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.71-73
    • /
    • 2019
  • The output current of the Grid Connected Inverter (GCI) can be polluted with harmonics mainly due to i) dead time in switches, ii) non-linearity of switches, iii) grid harmonics, and iv) DC link fluctuation. Therefore, it is essential to design the robust Harmonic Compensation (HC) technique for the improvement of output current quality and fulfill the IEEE 1547 Total harmonics Distortion (THD) limit i.e. <5%. The conventional harmonic techniques often are complex in implementation due to their i) additional hardware needs, ii) complex structure, iii) difficulty in tuning of parameters, iv) current controller compatibility issues, and v) higher computational burden. In this paper, to eliminate the harmonics from the GCI output current, a novel Digital Lock-In Amplifier (DLA) based harmonic detection is proposed. The advantage of DLA is that it extracts the harmonic information accurately, which is further compensated by means of PI controller in feed forward manner. Moreover, the proposed HC method does not require additional hardware and it works with any current controller reference frame. To show the effectiveness of the proposed HC method a 5kW GCI prototype built in laboratory. The output current THD is achieved less than 5% even with 10% load, which is verified by simulation and experiment.

  • PDF

Detection and Quantification of Defects in Composite Material by Using Thermal Wave Method

  • Ranjit, Shrestha;Kim, Wontae
    • 비파괴검사학회지
    • /
    • 제35권6호
    • /
    • pp.398-406
    • /
    • 2015
  • This paper explored the results of experimental investigation on carbon fiber reinforced polymer (CFRP) composite sample with thermal wave technique. The thermal wave technique combines the advantages of both conventional thermal wave measurement and thermography using a commercial Infrared camera. The sample comprises the artificial inclusions of foreign material to simulate defects of different shape and size at different depths. Lock-in thermography is employed for the detection of defects. The temperature field of the front surface of sample was observed and analysed at several excitation frequencies ranging from 0.562 Hz down to 0.032 Hz. Four-point methodology was applied to extract the amplitude and phase of thermal wave's harmonic component. The phase images are analyzed to find qualitative and quantitative information about the defects.

Modulated Finite Control Set - Model Predictive Control for Harmonic Reduction in a Grid-connected Inverter

  • Nguyen, Tien Hai;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.268-269
    • /
    • 2017
  • This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. Distorted grid condition is undesirable due to negative effects such as power losses and heating problem in electrical equipments. To enhance the power quality of distributed generation systems under such a condition, a modulated finite control set - model predictive control (MFCS-MPC) scheme will be proposed, in which the optimal switching signals of inverter are chosen by online basis using the principle of current error minimization. In addition, the moving average filter (MAF) is used to improve the phase-lock loop in order to obtain the harmonic-free reference currents on the stationary frame. The usefulness of the proposed MFCS-MPC method is proved by the comparative simulation results under different operating conditions.

  • PDF

Investigation on the effect of vibration frequency on vortex-induced vibrations by section model tests

  • Hua, X.G.;Chen, Z.Q.;Chen, W.;Niu, H.W.;Huang, Z.W.
    • Wind and Structures
    • /
    • 제20권2호
    • /
    • pp.349-361
    • /
    • 2015
  • Higher-mode vertical vortex-induced vibrations (VIV) have been observed on several steel box-girder suspension bridges where different vertical modes are selectively excited in turn with wind velocity in accordance with the Strouhal law. Understanding the relationship of VIV amplitudes for different modes of vibration is very important for wind-resistant design of long-span box-girder suspension bridges. In this study, the basic rectangular cross-section with side ratio of B/D=6 is used to investigate the effect of different modes on VIV amplitudes by section model tests. The section model is flexibly mounted in wind tunnel with a variety of spring constants for simulating different modes of vibration and the non-dimensional vertical amplitudes are determined as a function of reduced velocity U/fD. Two 'lock-in' ranges are observed at the same onset reduced velocities of approximately 4.8 and 9.4 for all cases. The second 'lock-in' range, which is induced by the conventional vortex shedding, consistently gives larger responses than the first one and the Sc-normalized maximum non-dimensional responses are almost the same for different spring constants. The first 'lock-in' range where the vibration frequency is approximately two times the vortex shedding frequency is probably a result of super-harmonic resonance or the "frequency demultiplication". The main conclusion drawn from the section model study, central to the higher-mode VIV of suspension bridges, is that the VIV amplitude for different modes is the same provided that the Sc number for these modes is identical.

광대역 아날로그 이중 루프 Delay-Locked Loop (Wide Range Analog Dual-Loop Delay-Locked Loop)

  • 이석호;김삼동;황인석
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.74-84
    • /
    • 2007
  • 본 논문에서는 기존의 DLL 지연 시간 잠금 범위를 확장하기 위해 새로운 이중 루프 DLL을 제안하였다. 제안한 DLL은 Coarse_loop와 Fine_loop를 포함하고 있으며, 와부 클럭과 2개의 내부 클럭 사이의 초기 시간차를 비교하여 하나의 루프를 선택하여 동작하게 된다. 2개의 내부 클럭은 VCDL의 중간 출력 클럭과 최종 출력 클럭이며 두 클럭의 위상차는 $180^{\circ}$이다. 제안한 DLL은 일반적인 잠금 범위 밖에 있을 경우 Coarse_loop를 선택하여 잠금 범위 안으로 이전 시킨 후 Fine_loop에 의하여 잠금 상태가 일어난다. 따라서 제안한 DLL은 harmonic lock이 일어나지 않는 한 항상 안정적으로 잠금 과정이 일어날 수 있게 된다. 제안한 DLL이 사용하는 VCDL은 두 개의 제어 전압을 받아 지연 시간을 조절함으로 일반적인 다 적층 currentstarved 형태의 인버터 대신에 TG 트랜지스터를 이용하는 인버터를 사용하여 지연 셀을 구성하였다. 새로운 VCDL은 종래의 VCDL에 비하여 지연시간 범위가 더욱 확장되었으며, 따라서 제안한 DLL의 잠금 범위는 기존의 DLL의 잠금 범위보다 2배 이상 확장되었다. 본 논문에서 제안한 DLL 회로는 0.18um, 1.8V TSMC CMOS 라이브러리를 기본으로 하여 설계, 시뮬레이션 및 검증하였으며 동작 주파수 범위가 100MHz${\sim}$1GHz이다. 또한, 1GHz에서 제안한 DLL의 잠금 상태에서의 최대 위상 오차는 11.2ps로 높은 해상도를 가졌으며, 이때 소비 전력은 11.5mW로 측정되었다.

전압 제어 임피던스 변환기를 이용한 전원주파수 적응형 능동 전력 필터의 구현 (An Implementation of Active Power Filler that Adopts to a Frequency Variation using the VCGIC(Voltage Controlled Generalized Impedance Converter)

  • 장목순;김상훈;이후찬;박종연
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.88-95
    • /
    • 2006
  • 본 논문은 분산전원의 주파수 변동에 적응하는 아날로그형의 능동 전력 필터를 제안하였다. 주파수 변동이 심한 분산전원에서 비선형부하에 의해 발생한 고조파의 제거를 위해 전원의 고조파 전류와 주파수가 같고 위상차가 $180[^{\circ}]$인 보상 전류를 투입함으로써 전원의 고조파를 제거하였다. 이때 보상전류의 생성을 위한 기준전류 검출회로는 변동하는 전원 주파수를 추적하고 적응하도록 PLL과 VCGIC(Voltage Controlled Generalized Impedance Converter)를 사용하였다. 시뮬레이션과 실험을 통해 제안된 시스템이 주파수가 변동하는 분산전원의 고조파 전류를 효과적으로 제거함을 증명하였다.

왜곡된 전원 전압하에서 Composite 관측기를 이용한단상 PWM 컨버터의 정현파 전류 제어 (Sinusoidal Current Control of Single-Phase PWM Converters under Voltage Source Distortion Using Composite Observer)

  • ;이동훈;이석규
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.466-476
    • /
    • 2011
  • 본 논문에서는 composite 관측기를 이용하여 전원전압 왜곡시 단상 PWM 컨버터의 고성능 전류제어를 제안한다. composite 관측기를 적용함으로써 전원 전압 및 전류의 기본파와 고조파 성분을 시간지연 없이 추출할 수 있다. 추출된 기본파 성분은 전원단의 페이저 각을 찾는 PLL시스템에 이용된다. 멀티 비례-공진 제어기로 단상 입력전류를 정현파로 제어하고 고조파 성분을 제거한다. 시뮬레이션과 실험 결과로 제안된 방법의 타당성을 검증한다.

밀리미터파 대역 국부발진 시스템 설계연구 (A Design Study of the Local Oscillator System for Millimeter Wave Band)

  • 이창훈;김광동;한석태;정문희;김효령;제도흥;김태성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 통신소사이어티 추계학술대회논문집
    • /
    • pp.77-80
    • /
    • 2003
  • We design the local oscillator system of the 100 GHz band radio receiving system for a cosmic radio observation. We use the YIG oscillator with digital driver which is the main oscillator. This oscillator has a good frequency and phase stability at some temperature variation, and the easy computer aided control characteristics. This total system designed to two subsystem, first is the oscillator system include YIG oscillator, tripler, harmonic mixer and triplexer etc., second is the PLL system to supply the precise and stable local oscillator frequency to mixer. The proposed local oscillator system in this paper can be use a single or multi pixel receiver because this system can be lock the local oscillator frequency automatically using PC.

  • PDF

YIG 발진기를 이용한 100㎓ 대역 국부발진 시스템 설계연구 (A DESIGN STUDY OF 100㎓ BAND LOCAL OSCILLATOR SYSTEM BY USING YIG OSCILLATOR)

  • 이창훈;김광동;김효령;정문희;한석태;제도흥;김태성
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권3호
    • /
    • pp.185-196
    • /
    • 2003
  • 본 논문에서는 100㎓ 대역 우주전파 수신시스템의 국부발진시스템에 대한 설계연구를 다루었다. 이 시스템의 기본 발진기로는 온도변화에 따른 주파수 및 위상 안정도가 좋고, 컴퓨터 제어가 용이한 디지털 드라이버를 사용하는 YIG 발진기를 사용하였다. 전체 시스템은 YIG 발진기, 3체 배기, 고조파 믹서 및 triplexer 등의 부품을 사용하는 발진부와 정확하고 안정된 국부발진 주파수를 만들어 믹서로 인가될 수 있도록 하는 PLL 시스템으로 구분하여 설계되었다. 본 연구에서 설계된 국부발진 시스템은 PC를 사용해 자동 혹은 수동으로 국부발진 주파수를 lock 할 수 있도록 설계되었으므로 밀리미터파 대역의 단일 픽셀 수신기나 다중 픽셀 수신기에 활용될 수 있다.