• Title/Summary/Keyword: hand strength

Search Result 1,509, Processing Time 0.03 seconds

Study on a recipe of recycled bumper and pristine materials for application of vehicle parts (재활용 범퍼의 효율적인 적용을 위한 신재의 최적 배합비율에 관한 연구)

  • Son, Younggon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.175-180
    • /
    • 2016
  • Waste bumpers from out-of-service vehicles are recycled in the manufacturing process of plastic parts by incorporating pristine materials after removing the coated paint on a bumper. This study examined the chemical properties and mechanical properties of a mixture of recycled bumper and pristine materials as a function of the mixing ratio. When the pristine materials and the recycled bumper pieces were mixed, the stiffness (tensile strength and the flexural modulus) was provided by their composition averages. On the other hand, the toughness (Izod impact strength and the elongation-at-break) was lower than their composition averages (i.e., negative deviation). FTIR analysis showed that these results were due to the absence of the compatibility between the pristine materials and recycled bumper pieces. When the recycled bumper pieces were loaded at more than 30 wt. %, the toughness decreased drastically. A previous study showed that a paint removal efficiency up to 80 wt.% was easily attainable. The other 20 wt.% of paint on the bumper is very difficult to remove. Therefore, this study examined the mechanical properties of a mixture of recycled bumper pieces containing the unremoved paint and recycled bumper pieces without paint. When the recycled bumper pieces containing the unremoved paint were incorporated in only small quantities, the mechanical properties were decreased to a great extent. These results show that the paint removal efficiency is very important in the recycled bumper industry.

Durability of GFRP Rebar with Ribs Containing Milled Alkaline Resistant Glass Fibers (알카리저항 초단유리섬유를 리브에 사용한 유리섬유 보강근의 내구성능)

  • Moon, Do Young;Oh, Hong Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.281-287
    • /
    • 2011
  • GFRP rebars could be deteriorated by concrete alkalinity. This paper focuses on the investigation of durability of GFRP rebars with ribs exposed to alkaline environment of concrete. It has been reported that the milled E-glass fibers in the ribs of GFRP rebar can increase bond strength between GFRP rebars and the concrete. In this study, the effect of milled alkaline resistant glass fibers (milled AR glass) and milled E-glass in the ribs on the durability of GFRP rebar is investigated through ISS tests and moist absorption tests of the bare rebar. To accelerate the effect of the alkalinity, high temperature($40^{\circ}C$) was applied. According to the test results, mix ratio of milled glass fibers in the ribs by weight had significant effect on durability of GFRP rebars with ribs. It is because that the high mix ratio may leads more voids in the ribs due to lower workability and formability. On the other hand, changing fiber type in the ribs from E-glass to AR-glass had no improvements on ISS strength of the GFRP rebar. Therefore, it is found that determination of proper mix ratio of milled glass fiber in the mixture for the formation of the ribs of the GFRP rebar is important.

Investigation on Influencing Environmental Factors on Health Status of Korean Septuagenarians Dwelling in Longevity Region in Jeonla Province (전라도 농촌장수지역 거주 70대 노인의 건강상태에 영향을 미치는 환경적 요인에 대한 탐색 연구)

  • Kwak, Chung Shil;Yon, Miyong;Lee, Mee Sook;Oh, Se In;Park, Sang Chul
    • Korean Journal of Community Nutrition
    • /
    • v.19 no.2
    • /
    • pp.142-162
    • /
    • 2014
  • Objectives: To evaluate the critical environmental factors on healthy-aging of Korean people, we investigated the significant factors influencing health status of septuagenarians living in rural area of Jeonla province, known to be one of the representative longevity regions in Korea. Methods: We divided subjects into healthy group (36M/25F) or poor-health group (26M/73F) based on self-reported health status, body mass index, a number of prescription, and blood test data. General characteristics, physical measurements, lifestyle, dietary behavior and nutrient intake, physical health and mental health data were statistically compared between the two groups. Results: Average age was not different between healthy group and poor-health group in men and women, respectively. In men, significantly favorable factors to health were observed to be higher education, regular exercise, higher grip strength and walking function, body mass index (${\geq}18.5kg/m^2$), moderate frequency of drinking and eating-out, non-smoking, normal red blood cell (RBC) count, higher serum dehydroepiandrosterone-sulfate (DHEAS) level, good digestive function and appetite, normal hearing function, regular meals, adequate vegetable and fruit intake, diverse food intake, adequate energy and nutrients (protein, vitamin $B_1$, $B_6$, C and E, folate, niacin, P, Zn and K) intake, higher mini-nutrient status assessment (MNA) score and low level of depression. On the other hand, in women, those were literacy, living arrangement, moderate frequency of drinking, healthy teeth, higher grip strength and walking function, bone mineral density, normal RBC and white blood cell (WBC) count, higher DHEAS concentration, higher MNA score, normal cognition and memory function, having snack and adequate fruit intake. Conclusions: These results could be useful to plan effective strategies to increase health-life expectancy of Korean old people living in rural areas.

Preparation and Characterization of Polyurethane Waterproof Coatings Containing Fly Ash

  • Lee, Sung-Il;Kim, Duk-Bae;Yang, Go-Su;Kim, Wan-Young;Byoun, Youn-Seop;Lee, Youn-Sik
    • Elastomers and Composites
    • /
    • v.38 no.3
    • /
    • pp.243-250
    • /
    • 2003
  • Polyurethane waterproof (PW) coatings are increasingly demanded in Korea for repairing cracks on old building roofs and construction of many sporting facilities. Calcium carbonate, a common filler, is incorporated in PW compositions. In this study, PW coatings were prepared by substituting a part of calcium carbonate with fly ash. The maximum amounts of calcium carbonate which can be substituted by fly ash obtained in the cyclone and bag filter dust collectors were 20 and 10%, respectively. It was found that the curing rate of PWs ran be controlled by varying the amount of Pb-octoate catalyst. The elongations at break as well as tensile strength and tear strength of PW coatings containing fly ash could also be adjusted such that their values were comparable to those of a standard PW coating by varying relative amounts of some components. However, the amount of cadmium, mercury, and lead leached from PW coatings containing fly ash obtained from the bag filter collector exceeded the respective allowed upper limits, mainly due to the initial high contents of them in the fly ash. On the other hand, PW coatings containing fly ash obtained from the cyclone collector exhibited better mechanical properties and did not release any significant amounts of the heavy metals. Thus, it was concluded that PW coatings containing fly ash can be utilized for practical applications as long as an appropriate fly ash is used.

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Study on the Scan Field of Modified Octupole and Quadrupole Deflector in a Microcolumn (마이크로칼럼에서 변형된 4중극 디플렉터와 8중극 디플렉터의 스캔 영역 비교)

  • Kim, Young Chul;Kim, Ho-Seob;Ahn, Seong Joon;Oh, Tae-Sik;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.1-7
    • /
    • 2018
  • In a microcolumn, a miniaturized electrostatic deflector is often adopted to scan an electron beam. Usually, a double octupole deflector is used because it can avoid excessive spherical aberrations by controlling the electron beam path close to the optical axis of the objective lens and has a wide scan field. Studies on microcolumns have been performed to improve the low throughput of an electron column through multiple column applications. On the other hand, as the number of microcolumns increases, the number of wires connected to the components of the microcolumn increases. This will result in practical problems during the process of connecting the wires to electronic controllers outside of the vacuum chamber. To reduce this problem, modified quadrupole and octupole deflectors were examined through simulation analysis by selecting an ultraminiaturized microcolumn with the Einzel lens eliminated. The modified deflectors were designed changing the size of each electrode of the conventional Si octupole deflector. The variations of the scan field and electric field strength were studied by changing the size of active electrodes to which the deflection voltage was to be applied. The scan field increased linearly with increasing deflection voltage. The scan field of the quadrupole deflector and the electric field strength at the center were calculated to be approximately 1.3 ~ 2.0 times larger than those of the octupole deflector depending on the electrode size.

An Analytical Study on Composite Beam Performance with Post-Fire Temperature Using ANSYS Program (ANSYS를 이용한 화재 후 온도에 따른 합성보 성능에 관한 해석적 연구)

  • Kwak, Sung-Shin;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.391-400
    • /
    • 2019
  • In the case of fire, a structure loses its original stiffness due to the temperature rise, and the load bearing capacity decreases. The loss of structural strength increases with increasing fire time of the structure. To prevent the collapse of buildings, it is very important to understand whether or not the members are damaged. On the other hand, there is insufficient data to be a guideline for diagnosing and evaluating the residual strength of the members in Korea. Therefore, this study examined the resistance performance by Finite-Element-Analysis of composite beams, which are composite structures among structural members. Composite beam modeling was carried out based on the model used in the Electrical Penetration Room (EPR) in cooperation with KEPCO. The heat transfer analysis and structural analysis of the critical phase were performed using ANSYS, a finite element analysis program. ANSYS was used to perform heat transfer analysis and structural analysis at the static analysis. To analyze the residual performance, the temperature distribution of the composite beam and the maximum displacement result of the heat-affected structure analysis were derived and the experimental data and the structural analysis result data were compared and analyzed.

Preparation and Properties of DMF-Based Polyurethanes Containing Bio-Polyol/Ester-Polyol for Wet-Type Polyurethane Artificial Leather (습식 인조피혁용 바이오 폴리올/폴리에스터 폴리올을 함유한 DMF 기반 폴리우레탄의 제조 및 물성)

  • Sur, Suk-Hun;Choi, Pil-Jun;Ko, Jae-Wang;Park, Ji-Hyeon;Lee, Jae-Yeon;Lee, Young-Hee;Kim, Han-Do
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2019
  • Recently, attention has been paid to obtaining bio-polyols from renewable resources. Successful use of these natural ingredients successfully produced in the industry for the synthesis of various polyurethanes is a very important task. In this study, a series of dimethylformamide (DMF) based polyurethanes were synthesized from methylene diphenyl diisocyanate (MDI)/1, 4-butanediol and bio-polyol (polytrimethylene ether glycol based on 1, 3-propanediol : B-POL)/polyester polyol (polyadipate diol based on 1,4-butandiol : H-PET). The effect of different ratio of bio-polyol (B-POL)/polyester polyol (H-PET) on the physical properties of polyurethane was investigated. As the B-POL content in B-POL/H-PET mixture increased, the glass transition of soft segment (Tgs) and tensile strength of polyurethane decreased, however, the elongation at break and tear strength increased. On the other hand, artificial leather was produced by wet process using synthesized DMF-based polyurethanes. It was found that there was almost no difference in the effect of the B-POL/H-PET composition on the average size and density (the number of cells per unit volume) of the porous cells formed in artificial leather. These results show that there is no problem in using bio-polyol (B-POL) based polyurethane for artificial leather produced by wet process.

Effect of Maximum Aggregate, Porosity, and Temperature on Crack Resistance and Moisture Susceptibility of Porous Asphalt Mixtures (최대입경, 공극률, 온도가 다공성 아스팔트 혼합물의 균열저항성 및 수분민감성에 미치는 영향)

  • Yoo, In-Kyoon;Lee, Su-Hyung;Park, Ki-Soo;Yoon, Kang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.611-619
    • /
    • 2021
  • Porous asphalt pavement (PAP) has many functions, such as reducing accidents and decreasing noise. On the other hand, vulnerability is inevitable because PAP contains approximately 20% porosity. This study evaluated the effects of the maximum aggregate size (MAS), temperature, and porosity on the PAP durability. The indirect tensile strength measures durability. This study tested the samples that stayed dry and were moisturized by freezing and thawing for mixtures having the same porosity of 20% and MAS of 13mm, 10mm, and 8mm. The same test was performed on a mixture of 20% and 22% voids made of the same material with a MAS of 10mm. As a result, for 20% porosity, significant differences in the changes in MAS and temperature were found. A clear difference was observed between 8mm and 13mm under dry conditions, but there were no other significant differences in the MAS change. Furthermore, there was a clear difference in temperature for the change in porosity and temperature, but the gap in 2% porosity at 20% did not show a clear difference. Therefore, it is necessary to develop a more durable PAP through quantitative evaluations of the factors affecting the PAP durability.

A Study for Field Application of Environmental-friendly Waterproof Method for Riverbed (친환경 하상차수공법 현장 적용성에 관한 연구)

  • Park, Minchul;Kim, Seonggoo;Kwak, Nokyung;Shin, Hyohee;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.1
    • /
    • pp.71-80
    • /
    • 2011
  • In period of rapid economic development, as doing river conservation work by using harmful materials environmental pollution has adversely effected humans, animals and plants frequently. For recovery of environmental pollution it needs a lot of time and cost. Therefore, in this study, in order to take an environment-friendly method which is also economical and durable both results of the laboratory model test and field test were compared and analyzed. According to the results of the laboratory model test, those methods such as concrete paving, asphalt paving, bentonite mat, stabilized soil method and mixed soil method have small amount of seepage, but on the other hand compaction soil, grassland and permeable materials have considerable amount of seepage. The results of field test show a similar tendency with laboratory test and have been satisfied to assess standard of domestic water permeability below $1.0{\times}10^{-7}cm/sec$ and unconfined compressive strength is also than 1.0MPa so it has been satisfied about standard. In conclusion, as compaction rate increased, as unconfined compression strength increased and coefficient of permeability decreased.