• Title/Summary/Keyword: hall measurement

Search Result 492, Processing Time 0.033 seconds

Measurement and Analysis of Electromagnetic field for DC electric railway train (직류철도차량에 대한 자계측정 및 분석)

  • Jang, Dong-Uk;Kim, Min-Cheol;Lee, Chang-Mu;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.

Objective evaluation of scattered sound field: Theory and methodology of diffuser design (확산음장의 물리적 평가 - 확산체 설계이론과 방법론 -)

  • Sato, Shin-Ichi;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.979-982
    • /
    • 2007
  • The effect of a scattering wall surfaces on sound diffusion can be assessed by determining the scattering and diffusion coefficients in the laboratory. However, the sound field in a concert hall including scattered reflections is different from the laboratory measurement condition. Therefore, there is a need for objective investigation of diffusion in real sound fields. In this paper, possible acoustical parameters of in-situ measurements are discussed.

  • PDF

A survey of actual conditions on the Kindergarten attached to colleges through actual measurement (실측을 통한 대학부설 유치원의 실태분석)

  • 석주영
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.10a
    • /
    • pp.51-55
    • /
    • 1994
  • This study was attempted to investigate the facilities and environments of kindergarten attached to colleges, and ultimately to make up the adequate environment of for children. For these purposes, investigators directly visited 6 kimdergartens attached to colleges, and actually measured the facilities and equipments of these kindergartens. Concretely, our invetigators analyzed the actual conditions of kindergarten attached to colleges contering around the lighting and illumination of classroom, corridor, hall, toile room, dining room, and furnitures, closing materials of the floor, wall, ceiling.

  • PDF

The Design of a Control & Measurement System for the Driving of Wheel-in Motor (휠인 모터 구동을 위한 제어 및 계측 시스템 설계)

  • Choi, Jung-Keyng
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.405-411
    • /
    • 2015
  • This paper sugg ests speed measurement and control system desig n methods to drive the Wheel-in Motor that is transfer rotational force to the hub of the wheel and drives it directly. The dsPIC30F2010 16 bit microprocessor specified to motion controller is used as a intelligent controller. The minimum functions of dsPIC30F2010, system clock, PWM output, I/O, timer, communication, applicable to motor control are used and operating characteristics of hall signal measurement and control software functions are tested. Also the algorithm including PDFF speed control program was implemented using this software functions and show the experimental results..

Efficient Measurement of Wind Velocity and Direction Using Dual Rotor Wind Power Generator in Vessel (Dual Rotor 풍력발전을 이용한 선박에서의 효과적인 풍향 풍속 측정)

  • Choi, Won-Yeon;Park, Gye-Do;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2010
  • This paper proposes an efficient measurement system for the velocity and direction of the wind using the dual rotor wind power generator in vessel. Conventional digital measurement system recognizes the direction and the velocity of the wind using the electric compass or synchronous motor and Vane probe method using hall sensors. But each system has its own short-comings: the synchronous motor has a larger measurement error than the magnetic compass and magnetic compass is weak for the external disturbances such as fluctuation of the vessel. To compensate these short-comings, this paper proposes a new compensation algorithm for the fluctuation errors according to the external interference and the unexpected movement of the vessel along the roll and pitch directions. The proposed system is implemented with the dual compasses and a synchronous motor. The proposed independent power generation system can be operated by itself and can raise the efficiency of the wind power generation systems of 30 ~ 400 W installed along the vertical and horizontal axes. The proposed system also realizes the efficient and reliable power production system by the MPPT algorithm for the real-time recognition of the wind direction and velocity. An advanced switching algorithm for the battery charging system has been also proposed. Effectiveness of the proposed algorithm has been verified through the real experiments and the results are demonstrated.

Investigation of the relationship between earthquakes and indoor radon concentrations at a building in Gyeongju, Korea

  • Kim, Jae Wook;Joo, Han Young;Kim, Rinah;Moon, Joo Hyun
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.512-518
    • /
    • 2018
  • This article measured and analyzed the indoor radon concentrations at one university building in Gyeongju, Republic of Korea, to investigate if there is any relationship between earthquakes and indoor radon concentration. Since 12 September 2016, when two 5.1 and 5.8 magnitude earthquakes occurred, hundreds of aftershocks affected Gyeongju until January 2017. The measurements were made at the ground floor of the Energy Engineering Hall of Dongguk University in Gyeongju over a period between February 2016 and January 2017. The measurements were made with an RAD7 detector on the basis of the US Environmental Protection Agency measurement protocol. Each measurement was continuously made every 30 minutes over the measurement period every month. Among earthquakes with 2.0 or greater magnitude, the earthquakes whose occurrence timings fell into the measurement periods were screened for further analysis. We observed similar spike-like patterns between the indoor radon concentration distributions and earthquakes: a sudden increase in the peak indoor radon concentration 1-4 days before an earthquake, gradual decrease before the earthquake, and sudden drop on the day of the earthquake if the interval between successive earthquakes was moderately longer, for example, 3 days in this article.