Measurement and Analysis of Electromagnetic field for DC electric railway train

직류철도차량에 대한 자계측정 및 분석

  • 장동욱 (한국철도기술연구원 전력연구팀) ;
  • 김민철 (한국철도기술연구원 전력연구팀) ;
  • 이장무 (한국철도기술연구원 전력연구팀) ;
  • 한문섭 (한국철도기술연구원 전력연구팀)
  • Published : 2005.07.18

Abstract

The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.