• Title/Summary/Keyword: half bridge inverter

Search Result 260, Processing Time 0.026 seconds

High frequency resonant inverter using time sharing control method for multipling output frequency (출력주파수체배 공진형 고주파 인버어터)

  • Bae, Y.H.;Hong, S.T.;Lee, H.W.;Kwon, S.K.;Seo, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1129-1132
    • /
    • 1992
  • This paper proposes a high frequency resonant inverter consisting of equivalent half bridge model using MOSFET. In this paper time-sharing control method is applied. as a result the output frequency is two times as high as switching frequency of device, and average current of device is incresed because of decreasing switching loss.

  • PDF

A Study on the Improvement of Performance of Power Supply for Ship's Emergency Lighting System (선박 비상조명용 전원장치의 성능개선)

  • Yang Hyun-Suk;Lee Su-Hun;Jeong Tae-Sun;Lee Sung-Geun;Kim Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.822-825
    • /
    • 2004
  • This paper describes the improvement of performance of power supply for ship's emergency lighting system(SELS). Proposed system is composed of power factor correction (PFC) circuit, emergency power supply system (EPSS), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit and microprocessor control system. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional relay type, and control power factor up to $97.5[\%]$ and input power up to $35.0[\%]$ by adjusting of pulse frequency of the HB inverter.

  • PDF

Analysis and Design of Single-stage Electronic Ballast for a Compact Fluorescent Lamps (컴팩트 형광램프용 일단계 전자식 안정기의 해석 및 설계)

  • Kim, Jong-Gil;Son, Yeong-Dae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.6
    • /
    • pp.441-449
    • /
    • 2000
  • Analysis, design and practical implementation of a single-stage electronic ballast for compact fluorecent lamps are presented in this paper. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bridge series resonant inverter. High power factor is achieved by using the boost semi-stage operating in discontinuous conduction mode, and inverter semi-stage operated above resonant frequency to provide zero voltage switching is employed to ballast the fluorescent lamp. Analytical and experimental results from the ballast system with 36W fluorescent lamps have demonstrated the feasibility of the proposed single-stage electronic ballast.

  • PDF

Frequency Control of an Electronic Ballast of Multiple Power Output for Fluorescent Lamps (주파수제어에 의한 형광램프용 다출력형 전자식 안정기의 설계)

  • 곽재영;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.47-52
    • /
    • 1995
  • This paper presents a new approach in the design of an electronic ballast for fluorescent lamps in the range of 10∼20W. The central point of the design lies in the equivalent concepts for a lamp and for the inverter part of an electronic ballast. The ballast, which adopts half-bridge inverter topology, is designed to adjust ifself to a predefined range of lamp power output by frequency control using MCU. At first, the circuit parameters were estimated using PSpice simulatio, and then were made varied according to the selection of an optimal frequency for each lamp. A series of experiments using fluorescent lamps of 11W, 15W, and 20W were carried out to verify the proposed design. As a result of the experiments, all the three lamps of different kind were run normally with the same ballast under consideration, And the characteristics on lamp starting and light output were satisfactory compared to existen single-output electronic ballasts.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

The Drive and Control Circuit Design of Cold Cathode Fluorescent Lamp for LCD Back Lighting (LCD 조광용 냉음극 형광램프의 구동 및 제어)

  • Kim Cherl-Jin;Hong Dae-Shik;Hwang Yo-Han;Yoon Shin-Yong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1211-1213
    • /
    • 2004
  • CCFL(cold cathode fluorescent lamp) are used to backlight of LCD(liquid crystal display). CCFL dimming methods are used to pulse frequency modulation(PFM) or pulse width modulation(PWM). In this paper, design of CCFL driving and control circuit by half-bridge type series and parallel resonant inverter that variable frequency modulation method to control the output voltage current. Inverter switching frequency is higher than resonant frequency for stable operating, and it is possible dimming control. On the basis of equivalent circuit, the validity of this study is confirmed by the comparison of simulation and experimental result.

  • PDF

A Study on Electronic Ballast with Improved Input Current Waveform (입력전류 파형 개선효과를 갖는 전자식 안정기에 관한 연구)

  • Heo Tae-Won;Son Young-Dae;Woo Jung-In
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1239-1241
    • /
    • 2004
  • In this paper, electronic ballast with Interleaved Boost Cell is presented. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bridge series resonant inverter High power factor and low THD(reduction of current ripple) are achieved by using the boost semi-stage operating in discontinuous conduction mode, and inverter semi-stage operated above resonant frequency to provide zero voltage switching is employed to ballast the fluorescent lamp. The experimental results from the ballast system with fluorescent lamps have demonstrated the feasibility of the proposed electronic ballast.

  • PDF

Design of 1500V solar inverter stack beyond megawatt in NPC1 topology

  • Hao, Xin;Ma, Kwok-Wai;Zhao, Jia;Sun, Xin-Yu
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.7-11
    • /
    • 2017
  • This paper describes a design concept of NPC1 power stack for 1500VDC megawatt level solar inverter. This stack uses three latest half-bridge IGBT modules with highest power density and operation junction temperature, which enable realization of power level beyond 1MW without paralleling. Critical design concept on loop inductance is explained. Dynamic characteristics are verified by double-pulse test. Thermal characteristics and output power limits are verified by thermal test. Temperature-sensitive component on PCB as output power constraint is identified. Different PCB repositioning solutions are tested to give the overall output power thermal derating curves, which enable output power of 1.15MW at $T_A=55^{\circ}C$ with $15^{\circ}C$ thermal margin. The power stack characteristic and performance change under different thermal environment is further analyzed.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

The suppression of high frequency leakage current using a new active Common Mode Voltage Damper (새로운 능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제)

  • Gu Jeong-Hoi;Bin Jae-Goo;Park Sung-Jun;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.151-154
    • /
    • 2001
  • This paper propose a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI. The new active common mode voltage damper is consisted of a half-bridge inverter and a common mode transformer with a blocking capacitor. Principle of the active common mode damper is as follow; by applying the compensation voltage which has the same amplitude and opposite polarity to the PWM inverter system. So, common mode voltage and high frequency leakage current can be reduced. Simulated and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF