• Title/Summary/Keyword: h-system

Search Result 20,637, Processing Time 0.05 seconds

Improvement of Group Delay and Reduction of Computational Complexity in Linear Phase IIR Filters

  • Varasumanta, Saranuwaj;Sookcharoenphol, Dolchai;Sriteraviroj, Uthai;Janjitrapongvej, Kanok;Kanna, Channarong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.955-959
    • /
    • 2003
  • A technique for realizing linear phase IIR filters has been proposed by Powell-Chau which gives a real-time implementation of H(z-1).H(z), where H(z) is a causal nonlinear phase IIR filter. Powell-Chau system is linear but not timeinvariant system. Therefore, that system has group delay response that exhibits a minor sinusoidal variation superimposed on a constant value. In the signal processing, this oscillation seriously degrade the signal quality. Unfortunately, that system has a large sample delay of 4L and also more computational complexity. Proposed system is present a reduced computational complexity technique by moved the numerator polynomial of H(1/z) out to cascade with causal filter H(z) and remain only all-pole of H(1/z), then applied truncated infinite impulse response to finite with truncated IIR filtel $H_L$(z) and L sample delay to subtract the output sequence from the top and bottom filter. Proposed system is linear time invariance and group delay response and total harmonic distortion are also improved.

  • PDF

Medium Voltage Inverter System Using Decentralized Control (분산제어를 이용한 고압인버터 시스템)

  • Jang, H.K.;Kim, H.J.;Jeon, J.H.;Yun, H.M.;Na, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.464-466
    • /
    • 2007
  • H-Bridge Multi-Level (HBML) 고압인버터는 저압의 반도체 소자를 사용하는 단상 H-Bridge 인버터로 구성 된 셀을 직렬로 연결함으로써 정현파에 가까운 고전압을 얻을 수 있고, 입 출력 고조파가 낮아서 필터가 필요 없는 토폴로지로 산업분야에서 사용이 확대되고 있다. 본 논문은 HBML 고압인버터의 마스터 제어기와 셀 제어기의 통신 하드웨어를 병렬로 구성하여서 하나의 전압지령 값과 Angle 값으로 셀에서 PWM을 구현 할 수 있는 분산제어 방식을 제안한다. 이 방식에서 셀 제어기가 전압, 전류, 주파수, 보호기능, 통신감시 정보 등 셀 제어의 대부분을 담당함으로써 마스터 제어기의 부담을 줄이고, 따라서 신호선의 개수를 줄일 수 있다. 또 통신하드웨어의 종단에 마스터 제어기를 연결만 하면 마스터제어기의 2중화가 가능하므로 사용하고 있던 마스터 제어기의 고장 발생 시에 대체하여 사용할 수 있으므로 시스템의 안정성 향상에 도움을 준다. 선간전압 33레벨로 구성된 HBML 고압인버터 시험을 통해 제안된 방식의 타당성과 신뢰성을 검증한다.

  • PDF

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

Development of a Rough Rice Handling Equipment for In-Bin Drying and Storage System (개량 곳간용 벼이송장치(移送裝置) 개발(開發))

  • Chang, D.I.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.44-51
    • /
    • 1988
  • The objective of this study is to develop a grain handling system for loading, unloading and transporting of rough rice stored at the in-bin drying and storage (IBDS) developed by the Korea Advanced Institute of Science and Technology(KAIST). A mechanized Fain handling system consisted of a portable auger and a gate was developed and tested. The test results can be summarized as the following: 1) The loading capacity of the handling system developed is $16.2m^3/h$ (8.3 ton/h) for the Indica type rice and $13.0m^3/h$(7.3 ton/h) for the Japonica type. It is greater than that of manual handling as much as 2.5 - 2.7 times. 2) The unloading capacity of the handling system developed is $16.0m^3/h$(8.2 ton/h) for the Indica type rice and $12.6m^3/h$(7.0 ton/h) for the Japonica type. It is greater than that of the manual as much as 4.7 - 5.5 times. 3) For 3-ton capacity of the storage, the loading and unloading can be performed for 20 and 30 minutes by one man operation of equipment. while 60 and 120 minute for the manual of 2 men, respectively. 4) The volumetric efficiency of the system developed is 0.42 - 0.54 and the power efficiency is 4.0 - 4.4. 5) The break-even quantity of the handling system developed is about 38.6 ton($68.7m^3$) of rough rice and the initial investment for the system would be returned within five years for the most owners of the KAIST IBDS system.

  • PDF

A Design of Model Following Optimal Multivariable BOiler-Turbine H_\infty Control System using Genetic Algorithm (유전 알고리즘을 이용한 모델 추종형 최적 다변수 보일러-터빈 H_\infty제어 시스템의 세계)

  • Hwang, Hyeon-Jun;Kim, Dong-Wan;Park, Jun-Ho;Hwang, Chang-Seon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.127-135
    • /
    • 1999
  • Multivarialbe Boiler-Turbine H_\infty Control System Genetic Algorithm Weighting Functions $W_1$(s), $W_2$(s), and design parameter $\gamma$ that are given by Glover-Doyle algorithm, to optimally follow the output of reference model. The first method to do this is that the gains of weighting functions $W_1$(s), $W_2$(s), and design parameter are optimized simultaneously by genetic algorithm with the tournament method that can search more diversely, in the search domain which guarantees the robust stability of system. And the second method is that not only by genetic algorithm with the roulette-wheel method that can search more fast, in that search domain. The boiler-turbine H_\infty control system designed by theabove second method has not only the robust stability to a modeling error but also the the better command tracking preformance than those of the H_\infty control system designed by trial-and-error method and the above first method. Also, this boiler-turbine H_\infty control system has the better performance than that of the LQG/LTR contro lsystem. The effectiveness of this boiler-turbineH_\infty control system is verified by computer simulation.

  • PDF

Simulation and Testing of the Effect of Current Collection Performance According to Pre-sag in 400km/h Overhead Contact Lines (400km/h 전차선로에서 사전이도가 집전성능에 미치는 영향에 대한 시뮬레이션 및 시험)

  • Kwon, Sam Young;Cho, Yong Hyeon;Lee, Kiwon;Oh, Hyuck Keun
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.288-296
    • /
    • 2016
  • A 400km/h simple catenary system was constructed as a test line in Korea. In the design stage of this system, the pre-sag was one of the engineering issues most focused on. It is known that the pre-sag improves the current collection performance in a certain band of high speed. However, the effect of pre-sag at 400km/h has not yet been established. To grasp a better pre-sag in the 400km/h catenary, we transacted the dynamic performance prediction simulation between catenary and pantograph under conditions of 0 and 1/3000 pre-sag. The level of 0 pre-sag was adapted for the 400km/h catenary design after reviewing predictions. We constituted the 1/3000 pre-sag sample section (about 1km) while constructing the 400km/h catenary test-bed (28km) of 0 pre-sag. With a HEMU-430X train, the contact forces were measured in the test-bed including the pre-sag sample section. In this paper, the predicted and measured dynamic performance values (contact forces) for 0 and 1/3000 pre-sag are described and compared. It is conclusively confirmed by analytical and experimental examination that the non pre-sag showed better dynamic (current collection) performance than that of the 1/3000 pre-sag for the 400km/h catenary system.

Lipid Peroxidation Induced by the Reaction of Cytochrome c with Hydrogen Peroxide

  • Kang, Jung-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.830-834
    • /
    • 2006
  • Lipid peroxidation induced by the reaction of cytochrome c with $H_2O_2$ was investigated. When linoleic acid micelles or phosphatidyl choline liposomes were incubated with cytochrome c and $H_2O_2$, lipid peroxidation was increased in cytochrome c and $H_2O_2$ concentrations-dependent manner. Radical scavengers, azide, formate and ethanol prevented lipid peroxidation induced by the cytochrome c/$H_2O_2$ system. Iron specific chelator, desferoxamine also prevented the cytochrome c/$H_2O_2$ system-mediated lipid peroxidation. These results suggest that lipid peroxidation may be induced by the cytochrome c/$H_2O_2$ system via the generation of free radicals. Carnosine, homocarnosine and anserine are present in the muscle and brain of many animals and human. Previous studies show that these compounds have an antioxidant function. In the present study, carnosine, homocarnosine and anserine significantly prevented the cytochrome c/$H_2O_2$ system-mediated lipid peroxidation. Carnosine and related compounds also inhibited the free radical-generating activity of cytochrome c. The results suggest that carnosine, homocarnosine and anserine may prevent lipid peroxidation induced by the cytochrome c/$H_2O_2$ system through a free radical scavenging.

[ $H_{\infty}$ ] LATERAL CONTROL OF AN AUTONOMOUS VEHICLE USING THE RTK-DGPS

  • Ryu, J.H.;Kim, C.S.;Lee, S.H.;Lee, M.H.
    • International Journal of Automotive Technology
    • /
    • v.8 no.5
    • /
    • pp.583-591
    • /
    • 2007
  • This paper describes the development of the $H_{\infty}$ lateral control system for an autonomous ground vehicle operating a limited area using the RTK-DGPS(Real Time Kinematic-Differential Global Positioning System). Before engaging in autonomous driving, map data are acquired by the RTK-DGPS and used to construct a reference trajectory. The navigation system contains the map data and computes the reference yaw angle of the vehicle using two consecutive position values. The yaw angle of the vehicle is controlled by the $H_{\infty}$ controller. A prototype of the autonomous vehicle by the navigation method has been developed, and the performance of the vehicle has been evaluated by experiment. The experimental results show that the $H_{\infty}$ controller and the RTK-DGPS based navigation system can sufficiently track the map at low speed. We expect that this navigation system can be made more accurate by incorporating additional sensors.

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

Gas removal efficiency of air washer system according to pH of sprayed water (분무수 pH 변화에 따른 에어와셔의 가스제거 성능변화)

  • Nam, Seung-Baeg;Ha, Jong-Pil;Kim, Tae-Hyung;Moon, In-Ho;Cho, In-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.488-492
    • /
    • 2007
  • In this study, experiment was done to verify the relationship between sprayed water's pH and gas removal efficiency of the Air Washer system. The experiment was done with sprayed water's pH in between pH 4.7 to 7.7, and Ion Chromatography analysis was used to identify the system's gas removal efficiency. As a result, $NH_3$ is removal efficiency decreased under 50% above pH 7, and $SO_X$ and $NO_X$ removal efficiency decreased under pH 6. Through this research, the optimum pH operating condition of the Air Washer System was conformed to be in range between pH6 to pH6.5.

  • PDF