• Title/Summary/Keyword: guidance

Search Result 5,041, Processing Time 0.049 seconds

Study of Selected IPCC Methodologies for the Estimation of Greenhouse Gas Emissions from a Landfill (매립지 온실 가스 배출량 산정을 위한 IPCC 선정방법별 특성 연구)

  • Jung, Sung Hoon;Hwang, Hyeon Uk;Kim, Myung Gyun;Yan, Cao Zheng;Nzioka, Antony Mutua;Tinega, Joseph Nyamoko;Kim, Young Ju
    • Resources Recycling
    • /
    • v.25 no.5
    • /
    • pp.28-35
    • /
    • 2016
  • The purpose of this study was to estimate greenhouse gas emissions using IPCC 1996 Guideline Tier 1, Good Practice Guidance 2000 Tier 2 and IPCC 2006 Guideline First Order Decay methods from landfill disposal facility. In addition, a comparative analysis evaluating the pros and cons of each method based on assumptions and default factors was considered for each method. The greenhouse gas emission computed using IPCC 1996 Guideline Tier 1 method (2,760 ton/yr) was higher than the estimation of GPG 2000 Tier 2 and IPCC 2006 Guideline First Order Decay Model which showed 1500 and 880 ton/yr respectively between 2000 and 2013.

Ultrasound-guided Extracorporeal Shock Wave Therapy Combined with Multiple Needling for Calcific Tendinitis in Shoulder (견관절의 석회화 건염에 대한 초음파 유도하 다발성 천공술 및 고에너지 체외 충격파 병합치료)

  • Jung, Tae Wan;Song, Dong Ik;Lee, Soon Hyuck;Jeoung, Woong Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: To evaluate the effectiveness of ultrasonography-guided combined multiple needling and high-energy extracorporeal shock wave therapy (ESWT) for calcific tendinitis of the shoulder. Materials and Methods: We included 42 calcific tendinitis patients who underwent ultrasonograpy-guided multiple needling followed by high-energy ESWT who visited the clinic from January 2010 to June 2013. The average follow up period was 45 weeks. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using pain visual analogue scale (P-VAS), ASES, UCLA scores reflecting performance and symptom improvement, and in sonographic terms by studying the changes in size of the calcific nodules. Results: A statistically significant improvement was seen in P-VAS, ASES, UCLA scores and decreased calcification size on sonographic evaluation. Conclusion: Ultrasonography-guided combined multiple needling and high-energy ESWT is considered as a useful method which could provide clinical function improvement and reduction of calcification deposit.

  • PDF

Research of a plan setting Secondary School Teacher Recruitment Test of Electricity·Electronics·Communication Subject (중등교사 임용시험 전기·전자·통신 과목의 출제방안 연구)

  • kim, Jinsu;Rho, Taechun;Ryu, BungRho;Eun, Taeuk
    • 대한공업교육학회지
    • /
    • v.31 no.2
    • /
    • pp.128-154
    • /
    • 2006
  • In the knowledge-based society, the quality of education is the core factor of national development. Above all, for improving educational quality, it is important to advance teacher's quality. Therefore, in order to maintaining high-level quality of education, it is required to select and appoint competent teacher. It deserves emphasis on importance of teacher recruitment test for maintaining high-level quality of education in this changes of age. Specially, Secondary School Teacher Recruitment Test of Electricity Electronics Communication Subject is declined qualitatively as each Subject of Electricity Electronics Communication is integrated and criterion of examination is obscured. This research analyzed The seventh curriculum and curriculum of Institution of Teacher Education of Electricity Electronics Communication Subject and already known examination of it On the basis of analyzing result, A field, proportion and points of examination decided through a expert conference are as follow: first, Teacher Recruitment Test of Electricity Electronics Communication Subject consists of subject pedagogics and contents. a proportion of subject pedagogics is 20% and subject contents is 80%. second, a subfield of subject contents consists of industrial education, industrial curriculum, industrial instruction method, practical guidance method, management of practical field organization, assesment of industrial education, industrial-educational cooperation and vocation and career education. third, subject contents consists of a common special, foundation special and application special field. a common a proportion of special field is 7.4%, foundation special is 20% and application special field which consists of electric field(21.3%), electronic field(21.3%) and communication field(10%) is 52.6%. fourth, Teacher Recruitment Test of Electricity Electronics Communication Subject execute practical technique test after finishing writing test.

A Study on GHS Classification of 3-Methylpentane by Subacute Inhalation Toxicity (아급성흡입독성시험을 이용한 3-Methylpentane의 GHS 분류·표시)

  • Chung, Yong Hyun;Han, Jeong Hee;Shin, Seo Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.6-17
    • /
    • 2017
  • Objectives : The purpose of this study was to obtain information regarding Globally Harmonized System(GHS) classification and health hazards that may result from a 4 weeks inhalation exposure of 3-Methylpentane in Sprague-Dawley rats. Methods : The testing method was conducted in accordance with OECD guidelines for the testing of chemicals No. 412(Subacute Inhalation Toxicity). The Rats were divided into 4 groups(5 male and 5 female rats in each group) and exposed to 0 ppm, 284 ppm, 1,135 ppm, 4,540 ppm 3-Methylpentane in each exposure chamber for 6 h/day, 5 days/week, for 4 weeks. After two weeks, the test animals were autopsied and carried out blood test and biochemical tests and histopathological examination. We used PRISTIMA (Toxicology data management system) to confirm the system and to have confidence of the raw data. Results : No death and particular clinical presentation including weight change and change of feed rate was observed. Relationship between dose, gender and response was also not significantly changed in hematologic examination, biochemical examination of blood and blood coagulation time. The histopathologic lesions caused by the test substance did not appear. Conclusions : NOAEL(No Observable Adverse Effect Level) of 3-Methylpentane is more than 4,540 ppm in male group and female group and the Ministry of Employment and Labor Guidance Announcement No. 2013-37(criteria for the classification marks and Safety of Chemicals) Specific target organ toxicity(repeated exposure) was determined with a substance that is not the separator material.

Terms Standardization between the Rules of Diagnosis Radiation Equipment Safety Management and Atomic Energy Law : Problems and Suggestions (진단용 방사선발생장치의 안전관리에 관한 규칙과 원자력법의 용어통일 개선 방향)

  • Kim, Hwa-Gon;Kang, Se-Sik;Kim, Chang-Soo;Park, Cheol-Seo
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • The rules and terms are described different meaning, in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. 1. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. 2. The following is omitted. 1) The radiation protection against tile patient and the hospital visitor. 2) Radiation dose limit of the woman patient who is in the process of becoming pregnant. 3) Radiation dose limit of the person who is not regarded as madical madical exposure. 4) The control of the exposure of pregnant of women at work.

  • PDF

Characteristics of Heavy Rainfall for Landslide-triggering in 2011 (2011년 집중호우로 인한 산사태 발생특성 분석)

  • Kim, Suk-Woo;Chun, Kun-Woo;Kim, Jin-Hak;Kim, Min-Sik;Kim, Min-Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.28-35
    • /
    • 2012
  • Rainfall is widely recognized as a major landslide-triggering factor. Most of the latest landslides that occurred in South Korea were caused by short-duration heavy rainfall. However, the relationship between rainfall characteristics and landslide occurrence is poorly understood. To examine the effect of rainfall on landslide occurrence, cumulative rainfall(mm) and rainfall intensity(mm/hr) of serial rain and antecedent rainfall(mm) were analyzed for 18 landslide events that occurred in the southern and central regions of South Korea in June and July 2011. It was found that all of these landslides occurred by heavy rainfall for one or three days, with the rainfall intensity exceeding 30 mm/hr or with a cumulative rainfall of 200 mm. These plotted data are beyond the landslide warning criteria of Korea Forest Service and the critical line of landslide occurrence for Gyeongnam Province. It was also found that the time to landslide occurrence after rainfall start(T) was shortened with the increasing average rainfall intensity(ARI), showing an exponential-decay curve, and this relation can be expressed as "T = $94.569{\cdot}exp$($-0.068{\cdot}ARI$)($R^2$=0.64, p<0.001)". The findings in this study may provide important evidences for the landslide forecasting guidance service of Korea Forest Service as well as essential data for the establishment of non-structural measures such as a warning and evacuation system in the face of sediment disasters.

The relation between a practical life and a bone mineral density for college students (일부대학생의 생활습관과 골밀도의 관계)

  • Kim, Sun-Chil;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.235-239
    • /
    • 2005
  • The bone mineral density built in adolescence and college term is formed to the highest level between 25 years old and 35 years old and the formed bone mineral density is decreasing in the middle years and senescence. Decrease of the bone mineral density causes Osteopenia and an increase of dangerousness of a bone fracture which become social health problems. This research is to give guidance for the right living style by surveying the relation between the bone mineral density and college students' life. The result is like below. First of all, most objects of the research were insufficient of quantity of motion and the diet they have was consisted of instant food. It was far from the right living habit and exercise and the bone mineral density was also low. Second of all, male students showed more osteopenia than female students in this research and the smokers' bone mineral density was lower than nonsmokers, which proved that smoking in adolescence was related to the bone mineral density. Finally, the opportunistic eating and living style and the excessive diet and unequal caloric intake caused by the notion of preference for a slim person are considered to be the main reasons for the decrease of the bone mineral density.

  • PDF

Analysis report for readiness posture against north korea nuclear threat - Focused mainly in non-military area of government readiness posture - (북한의 핵위협 대비태세 분석 - 정부의 비군사분야 대비태세를 중심으로 -)

  • Kim, In-Tae
    • Korean Security Journal
    • /
    • no.42
    • /
    • pp.205-227
    • /
    • 2015
  • The Korean Peninsula is put in a position to carry out a highly strategic game vis-a-vis nK, which is asserting itself as a nuclear power amongst Northeast Asia's complex dynamics. While the international community recognizes nK's possession of nuclear weapons as released secret based on nK's three nuclear tests, shrewd strategic thinking is needed by ROK to secure itself as a non-nuclear nation in order to assume a responsible role to the international community, while simultaneously being ready to respond at all times for nK's military provocations. ROK must continue with its twofold strategy, by firm response to military confrontation with nK and maintaining flexible policy of tolerance in the areas of economy and ethnicity. Various strategic options to overcome nK's nuclear threats have been presented to ROK, whose possession of nuclear weapons have been difficult, and nK's nuclear capability is a real threat to ROK's national security. We must be able to respond to nK's nuclear threats strictly from ROK's national security perspective. This thesis aims to propose a response policy for nK's nuclear capability and nK's nuclear attack based on analysis of such nuclear damage, ROK Government's response posture against nK's nuclear threats, centered around ROK Government's non-military response posture.

  • PDF

A three-dimensional kinematic analysis of the field goal kicking motion in American football (미식축구의 필드골(Field Goal) 킥(Kick)에 대한 운동학적 분석)

  • Ahn, Chan-Gyu;Kim, Ky-Hyung;Choi, Seung-Bang
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.1
    • /
    • pp.139-153
    • /
    • 2003
  • The purpose of the study was to present technical guidance about the field goal kicking motion in American football for novices. For this purpose, kinematic analysis on the field goal kicking motion of two skilled players and two unskilled players was carried out. The following conclusions were made: 1. In comparison on the total elapsed time of the kicking, there were no significant differences between two groups. The progressing time from BP event to impact among experts group, however, took 0.141 second less than that of novices group. 2. The experts group showed right hip rotatier horizontally toward the targeted ball fixing left hip as the axis. On the other hand, the novices group didn't use the left hip as the axis in the kicking motion. 3. At the impact of kicking the ball, regarding with the distance of the ball and the supporting leg, the right and left distance of experts was 3.45cm longer than that of novices, the front and the rear distance of experts was 5.14cm shorter than novices. 4. At the impact, experts' initial velocity of the targeted ball was $5.27^m/s$ faster than novices', besides experts' incidence angular displacement was $3.78^{\circ}$ larger than novices'. 5. After BP event, experts showed a stable movement maintaining flexion and extension at left hip joint and knee joint. On the other hand, for novices, the angle of the left lower extremities became larger. 6. Experts showed the efficient flexion and extension of the hip joint and the knee joint during following procedure in the whole event of the kicking motion. At the BP event, the right knee joint angle of novices was $11.46^{\circ}$ larger than that of experts. However, the duration of the impact event and FT event among, novices had less extension of knee joint than experts. 7. At the 2nd phase, for both of the groups, the angular velocity of the knee joint drastically increased as the angular velocity of hip joint decreased. However, only novices showed the largest negative angular velocity at the impact.

Small Break LOCA Analysis for RCP Trip Strategy for YGN 3&4 Emergency Procedure Guidelines (영광3, 4호기 비상운전지침용 원자로냉각재펌프 정지전략을 위한 소형냉각재상실사고 분석)

  • Seo, Jong-Tae;Bae, Kyoo-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.203-215
    • /
    • 1995
  • A continued operation of RCPs during a certain small break LOCA may increase unnecessary inventory loss from the RCS causing a severe core uncovery which might lead to a fuel failure. After TMI-2 accident, the CEOG developed RCP trip strategy called “Trip-Two/Leave-Two” (T2/L2) in response to NRC requests and incorporated it in the generic EPG for CE plants. The T2/L2 RCP trip strategy consists of tripping the first two RCPs on low RCS pressure and then tripping the remaining two RCPs if a LOCA has occurred. This analysis determines the RCP trip setpoint and demonstrates the safe operational aspects of RCP trip strategy during a small break LOCA for YGN 3&4. The trip setpoint of the first too RCPs for YGN 3&4 is calculated to be 1775 psia in pressurizer pressure based on the limiting small break LOCA with 0.15 ft$^2$ break size in the hot leg. The analysis results show that YGN 3&4 can maintain the core coolability even if the operator fails to trip the second too RCPs or trips at worst time. Also, the YGN 3&4 RCP trip strategy demonstrates that both the 10 CFR 50.46 requirements on PCT and the ANSI standards 58.8 requirements on operator action time can be satisfied with enough margin. Therefore, it is concluded that the T2/L2 RCP trip strategy with a trip setpoint of 1775 psia for YGN 3&4 can provide improved operator guidance for the RCP operation during accidents.

  • PDF