• Title/Summary/Keyword: groundwater flux

Search Result 83, Processing Time 0.02 seconds

Sulfur Cycle in the Rehabilitated Forest Catchment in Tanakami Mountain, Kansai District, Japan (일본 칸사이 지방 타나카미 산지의 황폐지 복구 산림유역 내 황(黃)순환에 관한 연구)

  • Kim, Su-Jin;Ohte, Nobuhito;Park, Jong-Kwan
    • Journal of the Korean Geographical Society
    • /
    • v.44 no.4
    • /
    • pp.429-446
    • /
    • 2009
  • To understand the sulfur flux and cycle in the forest catchment, the hydrological processes and chemical variation of soil solution, groundwater and stream water were analyzed at the Matsuzawa catchment located in the Kiryu Experimental Basin, Shiga Prefecture, central Japan. Unsaturated soil layer at the upper slope of catchment was the source area of ${SO_4}^{2-}$, and deep soil layer and groundwater were the sink zone of ${SO_4}^{2-}$. The vertical distribution of ${SO_4}^{2-}$ concentrations in groundwater affected seasonal variation of ${SO_4}^{2-}$ concentrations in stream water, as groundwater level changed. It is reasonable to assume that each hydrological processes in the forest catchment play an important roles in the retention and discharge of ${SO_4}^{2-}$.

Removal of Silica and Humic Acid from Brackish Water with Calcite (Calcite를 이용한 brackish water 내의 실리카와 휴믹산의 제거에 관한 연구)

  • 박소희;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.243-245
    • /
    • 2002
  • Brackish water desalination using reverse osmosis(RO) membrane is more useful and economic than sea water to solve the shortage of fresh water supply because of its low total dissolved solid(TDS) contents. Silica and humic acid in brackish water make serious fouling problems and cause the decline of permeate flux and increase of operating pressure. In this study, the experiments for removal of silica and humic acid were conducted with calcite particles to prevent membrane fouling and investigated the effect of pH of feed water Adsorption of silica to calcite was higher at pH=7.5 than 9.5 and removal rate was increased according to increase of initial concentration of silica. The effect of pH on adsorption of humic acid was not significant but at low initial concentration the adsorption of humic acid was enhanced at pH 7.5. The result of this study expect to apply to brackish water desalination experiment of flat-sheet reverse osmosis membrane.

  • PDF

Numerical simulations and related problems in multiphase flow and multicomponent transport (다중상 흐름과 다종성분의 거동에 관한 수치적 모의와 문제점)

  • 이강근;이진용;천정용;유동렬;하규철;이철효
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.27-31
    • /
    • 1998
  • Most models for the simulation of multi-phase flow and multi-species transport employ the capillary approach which uses the Darcy's law for the representation of mass flux of each phase. The capillary approach based on the Darcy's law require many empirical coefficients with complex functional dependencies rather than rigrous mathematical and physical formulation. The shortcoming of the capillary approach cause the numerical errors in the simulations by the multi-phase flow and transport models. This study discuss some of the problems related with the use of models.

  • PDF

Comparison of different surfactant system for simultaneous removal of nitrate and phosphate using micellar-enhanced ultrafiltration

  • 김보경;백기태;김호정;이율리아;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.417-421
    • /
    • 2003
  • Three kinds of surfactant systems - cationic surfactant (system 1), combinition of two cationic surfactants (system 2), and combination of two cationic surfactant and non-ionic surfactant (system 3) - for the simultaneous removal of nitrate and phosphate by micellar-enhanced ultrafiltration (MEUF) were investigated. The highest removal efficiencies of nitrate and phosphate were observed in system 2, which were 90 % of nitrate and 72 % of phosphate. The COD of permeate in system 3 was the lowest, because the added non-ionic surfactant made critical micelle concentration (CMC) lower than that of other surfactant systems. In all systems, the flux decline was similar.

  • PDF

Swelling and Relative Hydraulic Conductivities of transformed Ca-bentonite with various Na-cemicals

  • Chung Doug-Young;Lee Kyo-S.;Lee Dong-S.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.220-223
    • /
    • 2006
  • To investigate the effect of solution pH and particle size of Na-bentonite on swelling characteristics and relative hydraulic conductivity, four kinds of acids and two alkali were selected. The results showed that the swelling was decreased to half of the original Na-bentonite's swelling index. Also the decrease in SI was most distinctive in pH 3.5 of HCl. But changes of swelling index between initial and stabilized were minimal in alkali treatment, compared to the change by acid treatment. No flux was detected under atmospheric pressure although there was drastic decrease in swelling. However, leaching started after application of 1.5 bars of air-pressure equivalent to 15 m of water head.

  • PDF

2-Chlorophenol에 오염된 토양을 현장에서 처리하기 위한 Ozone-Venting 공정

  • 김정선;하현정;김현승;김일규
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.322-325
    • /
    • 2003
  • The feasibility of treating 2-chlorophenol (2CP) contaminated soils with ozone venting was investigated in this research. Adding ozone to the existing air-venting process provides an alternative to achieve a complete in-situ treatment by oxidizing the contaminant in the process. A column study with artificial soil was used to simulate the venting process. Ozone concentrations at 2.4, 7.6 and 19.4 mg/L, and flow rates at 100 and 150 mL/min were used. The reaction times were 10, 20, 50, and 60 minutes. Blank samples using air venting were also run for comparison. It is obvious that ozone-venting had a much faster removal rate than air-venting. As higher concentration of ozone is applied, the reaction rate increased significantly. As higher concentration was applied, the flux of ozone to the liquid film increased. This also increased the removal rate of 2CP and therefore the breakthrough curve came out earlier.

  • PDF

Application of PAC-Membrane System for Treating Groundwater Contaminated with Chlorinated Organic Compounds (유기염소화합물로 오염된 지하수를 처리하기 위한 PAC-막분리 공정의 적용)

  • Lim, Joong-Kun;Kang, Min-Su;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.892-899
    • /
    • 2005
  • Groundwater is naturally of excellent microbiological qualify and generally of adequate quality for drinking water use. However, recently, the impact of urbanization and intensification of agricultural production have led to serious deterioration in groundwater quality. The representative SOCs used in this study were trichloroethylene (TCE) and tetrachloroethylene (PCE). Powdered activated carbon (PAC) is widely used for SOCs removal. The overall goal of this study was to demonstrate the feasibility of using a hybrid use of PAC-UF and PAC-MF processes for treating groundwater contaminated with TCE and PCE. The results show that the flux decline rate was lower for the PAC-UF or PAC-MF process than for UF or MF only process. Therefore, applying PAC before UF or MF membrane filtration showed not only enhancing the removal of TCE and PCE, but also reducing membrane fouling.

Evidences of in Situ Remediation from Long Term Monitoring Data at a TCE-contaminated Site, Wonju, Korea

  • Lee, Seong-Sun;Kim, Hun-Mi;Lee, Seung Hyun;Yang, Jae-Ha;Koh, Youn Eun;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.6
    • /
    • pp.8-17
    • /
    • 2013
  • The contamination of chlorinated ethenes at an industrial complex, Wonju, Korea, was examined based on sixteen rounds of groundwater quality data collected from 2009 to 2013. Remediation technologies such as soil vapor extraction, soil flushing, biostimulation, and pumping-and-treatment have been applied to eliminate the contaminant sources of trichloroethylene (TCE) and to prevent the migration of TCE plume from remediation target zones. At each remediation target zone, temporal monitoring data before and after the application of remediation techniques showed that the aqueous concentrations of TCE plume present at and around the main source areas decreased significantly as a result of remediation technologies. However, the TCE concentration of the plumes at the downstream area remained unchanged in response to the remediation action, but it showed a great fluctuation according to seasonal recharge variation during the monitoring period. Therefore, variations in the contaminant flux across three transects were analyzed. Prior to the remediation action, the concentration and mass discharges of TCE at the transects were affected by seasonal recharge variation and residual DNAPLs sources. After the remediation, the effect of remediation took place clearly at the transects. By tracing a time-series of plume evolution, a greater variation in the TCE concentrations was detected at the plumes near the source zones compared to the relatively stable plumes in the downstream. The difference in the temporal profiles of TCE concentrations between the plumes in the source zone and those in the downstream could have resulted from remedial actions taken at the source zones. This study demonstrates that long term monitoring data are useful in assessing the effectiveness of remediation practices.

A Study on the Basic Characteristics of In-situ Soil Flushing Using Surfactant (계면활성제를 이용한 원위치 토양세정 기법 적용을 위한 기초 특성 연구)

  • 최상일;소정현;조장환
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.87-91
    • /
    • 2002
  • Lab scale batch and column tests were performed to investigate the treatability of petroleum contaminated soil using the in-situ soil flushing method. The pyrex column (4.5$\times$25 cm) was used to investigate optimal washing agent, surfactant concentration, mixing ratio, and inlet velocity. The miked surfactant of $POE_{14}$ and SDS were determined as ideal systems for the batch tests. From the results of preliminary tests, mixed surfactant was found to be more harmful for microorganisms. So $POE_{5}$ and $POE_{14}$ were chosen as the surfactant system for the batch study. The washing efficiency for the diesel contaminated soil was increased until 1 %, and decreased after l %. When applied as selected mixed surfactant, the ideal mixed ratio was recognized as 1:1. Therefore we selected miked surfactant $POE_{5}$ and $POE_{14}$, surfactant concentration 1%, and mixed ratio 1:1 for the remediation of diesel contaminated soil. In column tests, the total removal efficiency was improved as the flux of washing agent was increased. At the same pore volume, small flux showed better removal efficiency.

Forward and Back Diffusion from Low Permeability Zone: A Review of Analytical Solutions with Different Boundary Conditions (저투수성 매체 내 오염물질의 정확산과 역확산: 경계조건에 따른 용질이동 해석해의 소개)

  • Kim, Changmin;Yang, Minjune
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.99-110
    • /
    • 2020
  • It is a global trend to consider contaminated low-permeability zones as one of the primary management targets for the remediation of DNAPL contaminated sites. In addition, studies on the persistence caused by back diffusion of DNAPLs from low-permeability zones have been actively conducted worldwide. On the other hand, the studies for domestic groundwater contamination with the low-permeability zones are insufficient. Therefore, this study introduces the forward and back diffusions of DNAPL through low-permeability zones and suggests the importance of them by reviewing representative previous studies, especially on back diffusion and plume persistence. We proposed six diffusion scenarios and analytical solutions based on various boundary conditions of low-permeability zones. FI (forward diffusion into infinite domain) and BI (back diffusion form infinite domain) scenarios illustrate forward and back diffusion in which the depths of a low-permeability layer are assumed to be infinite. FFN (forward diffusion into finite domain with no flux boundary) and BFN (back diffusion from finite domain with no flux boundary) scenarios describe forward and back diffusion for a finite domain of a low-permeability layer with no flux boundary at the bottom. When the bottom of a low-permeability layer is considered as flux boundary, forward and back diffusion scenarios correspond to FFF (forward diffusion into finite domain with flux boundary) and BFF (back diffusion from finite domain with flux boundary). The scenarios and analytical solutions in this study may contribute to the determination of an efficient remediation method based on site characteristics such as a thickness of low-permeability zones or duration of contamination exposure.