2-Chlorophenol에 오염된 토양을 현장에서 처리하기 위한 Ozone-Venting 공정

  • Published : 2003.04.01

Abstract

The feasibility of treating 2-chlorophenol (2CP) contaminated soils with ozone venting was investigated in this research. Adding ozone to the existing air-venting process provides an alternative to achieve a complete in-situ treatment by oxidizing the contaminant in the process. A column study with artificial soil was used to simulate the venting process. Ozone concentrations at 2.4, 7.6 and 19.4 mg/L, and flow rates at 100 and 150 mL/min were used. The reaction times were 10, 20, 50, and 60 minutes. Blank samples using air venting were also run for comparison. It is obvious that ozone-venting had a much faster removal rate than air-venting. As higher concentration of ozone is applied, the reaction rate increased significantly. As higher concentration was applied, the flux of ozone to the liquid film increased. This also increased the removal rate of 2CP and therefore the breakthrough curve came out earlier.

Keywords