• 제목/요약/키워드: ground power supply

검색결과 198건 처리시간 0.021초

Analysis of Risk Voltage for Grounding Electrode by Injection of Earth Leakage Current

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon;Kil, Gyung-Suk
    • International Journal of Safety
    • /
    • 제8권2호
    • /
    • pp.9-14
    • /
    • 2009
  • This paper describes analysis of risk voltage for grounding electrode where earth leakage current is injected. To assess risk voltage of grounding electrode, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of a hemispherical water tank, AC power supply, a movable potentiometer, and test grounding electrodes. The shapes of grounding electrode model was ground rod. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the potential rise of ground rod abruptly decreases with increasing the distance from the grounding electrode to the point to be tested. The touch voltage above the ground rod was low, but the step voltage was high. The measured results were compared with the computer calculated data and were known in good agreement.

토픽모델링을 이용한 무인지상차량(UGV) 특허 동향 분석 (Patent Trend Analysis of Unmanned Ground Vehicles(UGV) using Topic Modeling)

  • 김기환;전차수;송지훈;전정환
    • 한국군사과학기술학회지
    • /
    • 제27권3호
    • /
    • pp.395-405
    • /
    • 2024
  • This study provides a thorough examination of Unmanned Ground Vehicles(UGVs), focusing on crucial technologies and trends across major global markets. It includes an in-depth patent analysis revealing the dominant positions of the United States and the European Union in this field. Additionally, it underscores substantial advancements made by China, Japan, and Korea since 2010. Using Latent Dirichlet Allocation(LDA)-based patent text mining, the study identified key technology areas in UGV development, such as advanced control systems, navigation technologies, power supply mechanisms, and sensing and communication tools. Through linear regression analysis, the study predicted the future paths of these technology areas, offering important insights into the evolving world of UGV technology. The findings can provide strategic guidance for stakeholders in the defense, commercial, and academic sectors, pointing out the future directions in UGV advancements.

MOS-GTO의 스위칭 특성과 Gate Drive 회로 설계에 관한 연구 (A study on the switching character of MOS-GTO and the design of gate drive circuit)

  • 노진입;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.231-233
    • /
    • 1991
  • This paper discribes a study on the switching character of MOS-GTO and the design of gate drive circuit. Chopping power supply converter, synchronious and asyncronious motor speed adjustment, inverter, etc., needs low drive energy "high frequency" switches. To fulfill these need, switches must have rapid switching time and insulated gate control. MOS-GTO structure is well suited to these constraints. The power switch is serial installation of a GTO thyrister and a MOS Transistor. The gate of the GTO is linked to positive pole of the cascode structure via a MOS high voltage transistor and ground via a transient absorber diode. This high performance MOS-GTO assembly considerably increases the strength which facilitate the drive of GTO thyristers.

  • PDF

공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구 (The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure)

  • 김기현;이상익;배석명;정찬웅;이재용
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

송전계통에서 고장에 따른 Gas Pipeline 유도전압 분석 (A Fault Effect to Induced Voltage of Gas Pipeline in Transmission Systems)

  • 김현수;이상봉;김철환
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1720-1725
    • /
    • 2008
  • Because of the continuous increasing of energy consumption, metallic pipelines are widely used to supply services to customers such as gas, oil, water, etc. Most common metallic pipelines are underground and are now frequently being installed in nearby electric power lines. In recent years, buried gas pipeline close to power lines can be subjected to hazardous induction effects, especially during single line to ground faults. because it can cause corrosion and it poses a threat to the safety of workers responsible for maintenance. Accordingly, it is necessary to take into consideration for analysis of induced voltage on gas pipelines in transmission lines. This paper analyzed the induced voltage on the gas pipelines due to the 154kV transmission lines in normal case and in different faulty case conditions using EMTP (Electro-Magnetic Transients Program).

전원설비에 의한 공간조건별 전위분포 사례 연구 (Case Studies for Potential Distribution due to Power Source by Environmental Condition)

  • 정진수;정종욱;김선구
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.50-58
    • /
    • 2011
  • In this paper, potential distribution analysis through the six kinds of case studies examined in the environmental conditions change within a limited space, by the power supply system installed. To interpret the potential distribution using electromagnetic field analysis program and the parameters were state of the ground, the outer wall of the configuration state and the presence of human potential distribution was simulated. Potential distribution analysis, the size of nominal voltage, depending on the impedance of human body to be determined on the impact of surprise decision, but if equipped with appropriate protective equipment can be protected from lightning have been confirmed.

$H_{\infty}$ 알고리즘을 이용한 Dynamic Voltage Restorer의 제어 (Dynamic Voltage Restorer Control Using $H_{\infty}$ Algorithm)

  • 전영환;김지원;전진홍
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제50권12호
    • /
    • pp.561-565
    • /
    • 2001
  • Recent trend of increasing automated factories needs supply of high quality power from the utilities. Among the items of the power quality, voltage sag can be compensated by Dynamic Voltage Restorer(DVR). The key feature of the DVR is high response with less transient period to recover from the voltage sag due to the lightning or line-to-ground faults. In this paper we report that $H_{\infty}$ controller is very promising for the practical application to the controller of DVR. Experimental results shown in this paper was obtained by applying the control algorithm to 20 kVA DVR system. The experimental set consists of IGBT-based three phase inverter and the TMS320C32-60 DSP used for main processor of the control board. To simulate the 50% voltage sag, the SCR-based experimental set was constructed.

  • PDF

지상 로봇의 비상 전원 공급을 위한 하이브리드 시스템 설계 (Hybrid System Design for Emergency Power Supply of Ground Robots)

  • 조영민;최주엽;최익;조상윤;이동하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.54-55
    • /
    • 2014
  • 일반적으로 지상 로봇의 주 전원으로 사용되는 대용량 배터리가 예상치 못한 시점에 방전되거나 고장으로 인해 전원 공급이 되지 않을 경우 지상 로봇의 위치 확인이 필요하게 된다. 이에 따라 본 논문에서는 이 통신용 비상 전원 공급을 위한 태양광 및 연료전지 전원 공급 장치와 이 장치를 보완하여 사용할 수 있는 배터리 충 방전 하이브리드 시스템을 설계하고, 이를 시뮬레이션과 실험을 통해 타당성을 검증 및 분석하도록 한다.

  • PDF

입자분산계 ER유체의 빙햄특성 고찰 (A Study on Bingham Characteristics of Particle Dispersive Electro-Rheological Fluid)

  • 장성철;이선의;김태형;박종근;염만오
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.178-183
    • /
    • 2000
  • Electrorheological(ER) effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of zeolite and starch based ER fluid were reported. The ER fluids were constructed by mixing zeolite and starch power with two different dielectric oils. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply. The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to $200s^{-1}$ in 2 minutes.

  • PDF

Analysis of Gate-Oxide Breakdown in CMOS Combinational Logics

  • Kim, Kyung Ki
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.17-22
    • /
    • 2019
  • As CMOS technology scales down, reliability is becoming an important concern for VLSI designers. This paper analyzes gate-oxide breakdowns (i.e., the time-dependent dielectric-breakdown (TDDB) aging effect) as a reliability issue for combinational circuits with 45-nm technology. This paper shows simulation results for the noise margin, delay, and power using a single inverter-chain circuit, as well as the International Symposium on Circuits and Systems (ISCAS)'85 benchmark circuits. The delay and power variations in the presence of TDDB are also discussed in the paper. Finally, we propose a novel method to compensate for the logic failure due to dielectric breakdowns: We used a higher supply voltage and a negative ground voltage for the circuit. The proposed method was verified using the ISCAS'85 benchmark circuits.