• 제목/요약/키워드: gold alloys

검색결과 96건 처리시간 0.025초

FRACTURE STRENGTHS OF CEROMER CROWNS SUPPORTED ON THE VARIOUS ABUTMENT CORE MATERIALS

  • Kim Young-Oh;Ku Chul-Whoi;Park Young-Jun;Yang Hong-So
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.647-653
    • /
    • 2004
  • Statement of problem. The effects of various core buildup materials which differs in the mechanical properties on the fracture strength of metal-free crowns is unknown. Purpose. This study was carried out to evaluate the fracture strengths of Artglass ceromer crowns supported by 3 different core materials in clinically simulated anterior tooth preparation. Material and methods. Ten crowns from each group were constructed to comparable dimensions on the various dies made by gold alloy, Ni-Cr alloy, and composite resin. The ten crowns were then cemented onto the dies and loaded until catastrophic failure took place. Fracture resistance to forces applied to the incisal edges of the anterior crowns supported by three types of dies was tested. Results. The ceromer crowns on the composite resin dies fractured at significantly lower values(287.7 N) than the ceromer crowns on the metal dies(approximately 518.4 N). No significant difference was found between the fracture values of the ceromer crowns on the dies of gold alloy and Ni-Cr alloy. Conclusion. The failure loads of the ceromer crowns on the metal dies were almost the same and not affected by the differences of casting alloys. However, the fracture values of the ceromer crowns on the resin dies were significantly reduced by the relative weak properties of composite resin core material.

자연치아 및 치과용 합금에 대한 도재표면 마모에 관한 실험적 연구 (An Experimental Study on Wear of Porcelain Surface to Natural Teeth and Crown Metal Alloys)

  • 이능수
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.47-54
    • /
    • 1981
  • Dental porcelains are widely used for restorative material because of its excellent esthetic property. But according to contact with natural teeth or metal in oral cavity, the porcelain may be worn and may effect on masticatory physiology and prosthetic function. The purpose of this experiment was to study on wear of porcelain surface which treated in different method. Using the abrasion device which was designed and constructed by myself, the different porcelain surface were abraded by gold alloy, nickel-chrome alloy and natural teeth in order to compare roughness. Results were as follows. 1. The group of porcelain abraded by gold alloy showed less surface roughness change (t=2.92, p<0.05), and the group of porcelain abraded by natural teeth had high surface roughness. change (t=6.84, p<0.05). 2. According to the method of surface treatment, the surface roughness were very significant (F=9.12, p<0.05). 3. After abrading, the porcelain surface roughness change was very significant (F=54.49, p<0.05). 4. There was no significant between surface treatment method and the kind of abrading materials. (F=1.01, p>0..05). 5. The group of natural glazing had the most smooth surface ($2.1{\pm}1.13{\mu}m$).

  • PDF

치과용 합금의 표면 처리가 글라스아이오노머 시멘트와 폴리카르복실레이트 시멘트의 결합력에 미치는 영향 (INFLUENCE OF SURFACE TREATMENTS OF DENIAL ALLOYS ON BOND STRENGTH OF GLASS IONOMER AND POLYCARBOXYLATE CEMENT)

  • 이헌우;우이형;임호남;최부병
    • 대한치과보철학회지
    • /
    • 제34권1호
    • /
    • pp.125-142
    • /
    • 1996
  • Bond strength of four different cements to dental casting alloys which were treated with #600 emery, tin-plating, and $50{\mu}m$ sandblasting were evaluated. The alloy specimens were Type III Gold alloy(Degulor C), Palladium-Silver alloy(Pors on 4), Nickel-Chromium(Rexillium III) alloy, which were embedded in acrylic resin disc. The specimens were treated with #600 emery and tin plating, #600 emery and sandblasting, then bonded using Fuji I, Ketac Cem(Glass ionomer cements), Poly F, Livcarbo(Polycarboxylate cements). The specimens were immersed in water for 24 hours and shear bond strengths were evaluated by Instron Machine. Tin plated, sandblasted, and debonded alloy surfaces were observed using scanning electron microscope. On the basis of this study, the following conclusions could be drawn. 1. In the tin plated alloy group, increase in bond strength of glass ionomer cements was statistically insignificant. 2. In the tin plated alloy group, increase in bond strength of polycarboxylate cements was statistically significant, except nickel-chromium alloy. 3. Sandblasted alloy group showed higher bond strength than that of tin-plated alloy group.

  • PDF

다양한 조성의 Sn-Ag-Cu 합금계 무연 솔더볼과 ENIG(Electroless Ni Immersion Gold), Cu-OSP(Oraganic Solderability Preservertive) 금속 패드와의 계면 반응 연구 (A Study of the Interfacial Reactions between Various Sn-Ag-Cu Solder Balls and ENIG (Electroless Ni Immersion Gold) and Cu-OSP (Organic Solderability Preservative) Metal Pad Finish)

  • 박용성;권용민;손호영;문정탁;정병욱;강경인;백경욱
    • 마이크로전자및패키징학회지
    • /
    • 제14권4호
    • /
    • pp.27-36
    • /
    • 2007
  • 본 논문에서는 다양한 조성의 주석-은-구리 합금계 솔더볼과 ENIG 및 Cu-OSP 패드와의 계면 반응에 대해 연구하였다. ENIG 패드와 미량의 Sb이 첨가된 합금 솔더와의 계면 반응 시 다른 솔더에 비해 매우 얇은 100 nm 내외의 두께를 가진 P-rich Ni layer가 형성되었다. 미량의 Ni이 첨가된 합금 솔더와 Cu-OSP 금속 패드와의 계면 반응 시에는 다른 솔더와는 달리 균일한 두께의 $Cu_6Sn_5$ 금속간화합물이 형성되었으며 추가 리플로우 시에 금속간화합물 입자가 거의 성장하지 않았다. 또한 $150^{\circ}C$의 장시간 열처리 시에 다른 솔더에 비해 매우 얇은 두께의 $Cu_3Sn$ 금속간화합물이 형성되었다.

  • PDF

각종(各種) 금속치관(金屬齒冠)이 치간(齒齦)에 미치는 영향(影響)에 관(關)한 실질적(實驗的) 연구(硏究) (Experimental studies on Gingival Response to Dental Restorations.)

  • 이영추
    • 대한치과보철학회지
    • /
    • 제8권1호
    • /
    • pp.42-47
    • /
    • 1968
  • The purpose of this study was to determine the gingival response to the various restorations for 3 weeks, 5 weeks and 8 weeks respectively after they had been inserted in 36 tooth of 3 dogs. The histopathological observation was also performed to evaluate the effect of the various restorations on gingival tissue. They included gold, copper and nickel-chrome alloy. The following findings were obtained. 1. The gingivae adjacent to the well adapted and polished restorations and their margins with a level of gingival crest were grossly and histopathologically found no specific changes. 2. The gingive adjacent to the ill fitting and unpolished restorations and their margins with subgingival extension of 1 to 1.5mm were not grossly found any changes. 3. There were no obvious difference in gingival response among the various alloys in histopathological observation.

  • PDF

Fiber Reinforced Framework를 이용한 Implant 수복증례 (Implant Restorations Using Fiber Reinforced Framework)

  • 송호용;이양진;조리라
    • 대한심미치과학회지
    • /
    • 제10권2호
    • /
    • pp.21-30
    • /
    • 2001
  • Fiber reinforced materials have favorable mechanical properties. Moreover, the strength to weight ratios of this material is superior to those of most alloys. Comparing to the metals, it showed many other advantages as well, including non-corrosiveness, translucency and easy repair characteristic. Since, it has the potential for the chair-side and laboratory fabrication, it is not surprising that fiber reinforced composites offer the potential for use in various applications in dentistry. To make the well-fitted restorations, Fiber reinforced composite (FRC) has been suggested as an alternative framework material for the implant supported fixed prosthesis. Two fixed partial denture fabrication procedures were tried. Vectris fiber was pressed to the EsthetiCone gold cylinder on the implant positioned cast. And then, Targis were added on it. In the other method, we used the customized component using UCLA abutment. The beads for retaining the Vectris fiber were added on the abutment. If careful laboratory and clinical techniques were done, these two techniques would fulfill the demands of the esthetics and strength.

  • PDF

인듐, 주석, 동 첨가에 따른 도재소부용 금합금의 기계적 특성 변화 (Mechanical properties of porcelain fused gold alloy containing indium, tin and copper)

  • 남상용;곽동주;이덕수
    • 대한치과기공학회지
    • /
    • 제24권1호
    • /
    • pp.65-71
    • /
    • 2002
  • This study was performed to observe the microhardness change of the surface and the bonding strength between the porcelain and alloy specimens in order to investigate the effects of appended indium, tin and copper on interfacial properties of Au-Pd-Ag alloys. The hardness of castings was measured with a micro-Vicker's hardness tester. The interfacial shear bonding strength between alloy specimen and fused porcelain was measured with a mechanical testing system(MTS 858.20). The microhardness of Au-Pd-Ag alloy was increased by adding indium and tin, but not increased by adding copper. The shear bonding strength of Au-Pd-Ag-Sn alloy and Au-Pd-Ag-Cu alloy showed 87MPa, 57MPa. The higher concentration of adding elements showed the higher shear bonding strength.

  • PDF

부적합한 금관이 치아주위조직에 미치는 영향에 관한 실험적 연구 (Effects of Improper Metal Crown to Period Onium in Experimental the Dogs)

  • 조근옥
    • 대한치과의사협회지
    • /
    • 제11권5호
    • /
    • pp.353-358
    • /
    • 1973
  • The purpose of this study was to determine the gingival response to the various restorations for 3 weeks, 5 weeks and 8 weeks respectively after they had been inserted in 42 tooth of 5dogs. The histopathological observation was also performed to evaluate the effect of the variuos restorations on gingival tissue. They inclued gold, copper and nickel-chrome alloy. The following findings were obtained. 1. The gingivae adjacent to the well adapted and polished restorations and their margins with a level of gingival crest were grossly and histopathologically found no specific changes. 2. The gingive adjacent to the ill fitting and unpolished restorations and their margins with subgingival extension of 1 to 1.5mm were not grossly found any changes but hitopathologically, the inflammatory changes. 3. Thee wee no obvious difference in gingival response among the various alloys in histopathological observation.

  • PDF

Light emitting diode를 이용한 광중합 시 금합금과 교정용 금속 브라켓의 전단접착강도 (Shear bond strength between gold alloy and orthodontic metal bracket using light emitting diode curing light)

  • 정민호;정신혜;손원준
    • 대한치과교정학회지
    • /
    • 제40권1호
    • /
    • pp.27-33
    • /
    • 2010
  • 성인 교정환자의 수요가 증가하면서 보철물 표면에 교정장치를 부착해야 하는 빈도가 늘어나고 있다. 본 연구는 금속표면에 교정장치를 직접 접착하고자 할 때 사용하는 metal primer와 silicoating으로 각각 금합금의 표면을 처리한 후 light emitting diode (LED) 광중합기를 사용하여 광중합을 시행하여 접착력을 평가해 보고자 하였다. Type III gold alloy 표면에 aluminum oxide를 이용한 sandblasting 후 4-META 계열의 metal primer로 처리한 시편과 silica를 이용한 sandblasting 후 silane으로 처리한 시편에 광중합형 접착레진인 Transbond XT를 이용하여 금속 브라켓을 접착하고 접착 후 1시간, 6시간, 24시간 후 전단접착강도의 변화를 비교, 관찰하였다. 측정된 값을 이원분산분석(two-way analysis of variance)을 이용하여 비교하고 두 가지 표면처리 방법 간에 접착강도에 차이가 있는지도 살펴보았다. 연구결과, metal primer에 비하여 silicoating을 시행한 시편에서 높은 전단접착강도가 관찰되었으며, 시간이 경과할수록 접착강도가 증가하는 경향을 보였다. Adhesive remnant index (ARI)에서는 군 간 유의한 차이를 보이지 않았다. LED를 이용하여 광중합을 시행하는 경우 법랑질에 비하여 긴 시간의 광중합을 실시하고 metal primer보다는 silicoating 방법을 사용하는 것이 금합금표면에 교정장치를 부착할 때 더 높은 접착강도를 얻을 수 있을 것이다.

Titanium Ions Released from Oral Casting Alloys May Contribute to the Symptom of Burning Mouth Syndrome

  • Park, Yang Mi;Kim, Kyung-Hee;Lee, Sunhee;Jeon, Hye-Mi;Heo, Jun-Young;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • 제42권4호
    • /
    • pp.102-108
    • /
    • 2017
  • Purpose: Many metal ions released from dental casting alloys have been reported to influence the intraoral symptoms of oral lichen planus (OLP) and burning mouth syndrome (BMS). The aim of this study was to investigate the relationship between salivary metal ion levels and the prosthetic duration as well as to evaluate the time-dependent morbid effects of metal ions in OLP and BMS patients. Methods: Three study groups consist of the following subjects respectively: 17 OLP patients, 12 BMS patients, and 12 patients without oral symptoms. The salivary concentrations of 13 metal ions (copper, cobalt, zinc, chromium, nickel, aluminum, silver, iron, titanium [Ti], platinum, tin, palladium, and gold) were measured by Laser Ablation Microprobe Inductively coupled Plasma Mass Spectrometry. Results: The Ti ions had statistically significant differences among the groups with a prosthetic duration of less than 5 years. There were no significant differences between all ion levels among the groups wearing dental cast alloys for over 5 years. In the BMS group, the level of Ti ions in patients with prosthetic restorations less than 5 years old were significantly high (p<0.05). Conclusions: In the BMS group, 3-60 months during which salivary Ti levels were higher were matched with the duration of burning symptoms ($15.6{\pm}17.1months$). Furthermore, Ti ions were statistically high in the oral cavity of BMS patients fitted with dental casting alloys for 5 years. These results suggest that Ti ions released from dental implants and oral prostheses could attribute to burning sensation of BMS.