• 제목/요약/키워드: gold alloy

검색결과 233건 처리시간 0.031초

18K 레드 골드 정함량 솔더의 In 첨가에 따른 물성변화 (Properties of the 18K Red Gold Solder Alloys with Indium Contents)

  • 송정호;송오성
    • 한국재료학회지
    • /
    • 제28권2호
    • /
    • pp.89-94
    • /
    • 2018
  • The properties of 18 K red gold solder alloys were investigated by changing the content of In up to 10.0 wt% in order to replace the hazardous Cd element. Cupellation and energy dispersive X-ray spectroscopy (EDS) were used to check the composition of each alloy, and FE-SEM and UV-VIS-NIR-Colormeter were employed for microstructure and color characterization. The melting temperature, hardness, and wetting angle of the samples were determined by TGA-DTA, the Vickers hardness tester, and the Wetting angle tester. The cupellation result confirmed that all the samples had 18K above 75.0wt%-Au. EDS results showed that Cu and In elements were alloyed with the intended composition without segregation. The microstructure results showed that the amount of In increased, and the grain size became smaller. The color analysis revealed that the proposed solders up to 10.0 wt% In showed a color similar to the reference 18 K substrate like the 10.0 wt% Cd solder with a color difference of less than 7.50. TGA-DTA results confirmed that when more than 5.0 wt% of In was added, the melting temperature decreased enough for the soldering process. The Vickers hardness result revealed that more than 5.0 wt% In solder alloys had greater hardness than 10.0 wt% Cd solder, which suggested that it was more favorable in making a wire type solder. Moreover, all the In solders showed a lower wetting angle than the 10.0 wt% Cd solder. Our results suggested that the In alloyed 18 K red gold solders might replace the conventional 10.0 wt% Cd solder with appropriate properties for red gold jewelry soldering.

전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구 (A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING)

  • 한의택;김영수;김창회;양재호
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

2종의 열가압 도재와 법랑질 간의 마모에 관한 연구 (An in-vitro wear study of human enamel opposing heat-pressed ceramics)

  • 박찬용;전영찬;정창모;윤미정
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2009
  • 연구목적: 2종의 열가압 도재 (e.max Press, Empress Esthetic)와 법랑질 간의 마모양상을 알아보기 위하여 장석계 도재 및 제 3형 금합금과 비교, 관찰하였다. 연구 재료 및 방법: 열가압 도재 e.max Press, Empress Esthetic 및 금속도재관 제작용 장석계 도재 Cermaco 3, 제 3형 금합금으로 원반형 시편을 제작하고, 상대 마모재로는 발거된 건전한 소구치의 교두를 이용하여 Pin-on-disk tribometer 상에서 마모시험 하였다. 법랑질의 마모량은 마모 전후 치아 시편의 무게 변화를 측정하여 부피로 환산하였고, 도재 및 금합금 시편의 평균 표면 조도와 마모트랙 깊이를 표면조도기로, 마모트랙 폭을 주사전자현미경으로 측정하여 마모 양상을 비교하였다. 결과: 1. 법랑질의 마모량은 Ceramco 3군에서 가장 크고 Empress Esthetic군, e.max Press군, 금합금군 순으로 작았으며, Ceramco 3군과 Empress Esthetic군 사이와, Empress Esthetic군, e.max Press군 및 금합금군 사이에는 유의한 차이가 없었다 (P>.05). 2. 마모시험 후 도재 시편의 평균 표면 조도는 Ceramco 3군, Empress Esthetic군, e.max Press군 순으로 작았으며, Empress Esthetic군과 Ceramco 3군 사이에는 유의한 차이가 없었다 (P>.05). 3. 마모트랙의 깊이는 모든 군 사이에 유의한 차이는 없었고 (P>.05), 마모트랙의 폭은 법랑질 마모량 순서와 동일하게 Ceramco 3군, Empress Esthetic군, e.max Press군, 금합금군 순으로 작았으며, e.max Press군과 Empress Esthetic군 사이 및 Empress Esthetic군과 Ceramco 3군 사이에 유의한 차이는 없었다 (P>.05). 결론: 열가압 도재는 장석계 도재보다 법랑질을 더 마모시키지는 않았다.

수종 임플랜트 지대주나사의 반복하중 후 나사풀림에 관한 연구 (A STUDY OF SCREW LOOSENING AFTER DYNAMIC CONTINOUS FATIGUE TEST OF SEVERAL ABUTMENT SCREW)

  • 김진만;한중석;이선형;양재호;이재봉;김영수
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.519-531
    • /
    • 2003
  • Statement of problem : Chronic implant screw loosening remains a problem in restorative practices. Some implant manufactureres have introduced abutment screws with treated material, surfaces and macrostructures in an effort to reduce potential loosening. Purpose : This study evaluated the materials and loading cycles on detorque value after dynamic continous fatigue test in the sinulated conditions of posterior single restoration. Material and method : Fourteen of each of the following abutment screws - titanium alloy, gold alloy, gold-tite, and titanium alloy modified - were used in test. SEM is used to verify macrostructures of each screws. $ZrO_2/Al_2O_3$ composite abutment was tightened on $4{\times}10.0mm$ titanium external implant at 30 Ncm. Cyclic loading machine delivered dynamic loading forces between 20 and 320N for 100,000, 200,000, 300,000, 500,000, and 1,000,000 cycles at frequencies 14Hz. Torque and detorque value after loading was measured. Results : All measued screws had different screw length and thread form. Titanium modified screw had greater detorque value than others before and after cyclic loadings(p<0.05). All abutment screws had no significant change in mean percentage of detorque value after loading to initial value after less than 500.000 cyclic loadings, but significant lower value after 1,000,000 cycles(p<0.05). Conclusion : Within limintations of this study all abutment screws may be loosend after about 1 year use. Annual check-up is nessasary to prevent screw loosening.

가철성(可撤性) 국부의치(局部義齒)에서 연합(聯合) Clasp 연결부위(連結部位)의 미세구조(微細構造) (MICROSTRUCTURE OF COMBINATION CLASP JOINTS IN REMOVABLE PARTIAL DENTURE)

  • 손한기;김태완
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.123-132
    • /
    • 1984
  • 매몰(埋沒) 납착법과 가공선(加工線) 봉매(封埋) 주조법(鑄造法)에 의해 국부의치(局部義齒)의 금속(金屬)과 가공선(加工線)을 각각(各各) 귀금속(貴金屬) 및 비귀금속(非貴金屬)으로 제작(製作)하였을 때 연합(聯合) clasp 연결부(連結部)의 미세구조(微細構造)를 금속(金屬) 현미경(顯微鏡)으로 관찰(觀察)하여 다음과 같은 결과(結果)를 얻었다. 납착 및 주조시편(鑄造試片) 공(共)히 연결부위(連結部位)의 미세조직(微細組織)은 확산(擴散)에 의한 다소(多少)의 결정립계(結晶粒界)의 변화(變化)를 관찰(觀察)할 수 있었다. 납착시편에서는 비귀금속(非貴金屬)보다 귀금속(貴金屬) 사용(使用)시 양호(良好)한 결합양상(結合樣相)을 나타내었다. 납착시편에서는 귀금속(貴金屬) 및 비귀금속(非貴金屬) 차이(差異)보다는 같은 계통(系統)의 금속(金屬)을 사용(使用)함으로서 보다 양호(良好)한 결합양상(結合樣相)을 나타내었다. 주조시편(鑄造試片)과 납착시편 모두에서 시편제작(試片製作)의 기술적(技術的)인 방법(方法)에 의해 다소(多少)의 기공(氣孔) 및 산화물(酸化物) 형성(形成) 등(等)과 같은 오염(汚染)된 계면부(界面部)가 나타났다.

  • PDF

Effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations: in vitro study of color masking ability

  • Oh, Seon-Hee;Kim, Seok-Gyu
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.368-374
    • /
    • 2015
  • PURPOSE. The aim of the study was to evaluate the effect of abutment shade, ceramic thickness, and coping type on the final shade of zirconia all-ceramic restorations. MATERIALS AND METHODS. Three different types of disk-shaped zirconia coping specimens (Lava, Cercon, Zirkonzahn: ${\phi}10mm{\times}0.4mm$) were fabricated and veneered with IPS e.max Press Ceram (shade A2), for total thicknesses of 1 and 1.5 mm. A total of sixty zirconia restoration specimens were divided into six groups based on their coping types and thicknesses. The abutment specimens (${\phi}10mm{\times}7mm$) were prepared with gold alloy, base metal (nickel-chromium) alloy, and four different shades (A1, A2, A3, A4) of composite resins. The average $L^*$, $a^*$, $b^*$ values of the zirconia specimens on the six abutment specimens were measured with a dental colorimeter, and the statistical significance in the effects of three variables was analyzed by using repeated measures analysis of variance (${\alpha}$=.05).The average shade difference (${\Delta}E$) values of the zirconia specimens between the A2 composite resin abutment and other abutments were also evaluated. RESULTS. The effects of zirconia specimen thickness (P<.001), abutment shade (P<.001), and type of zirconia copings (P<.003) on the final shade of the zirconia restorations were significant. The average ${\Delta}E$ value of Lava specimens (1 mm) between the A2 composite resin and gold alloy abutments was higher (close to the acceptability threshold of 5.5 ${\Delta}E$) than th ose between the A2 composite resin and other abutments. CONCLUSION. This in-vitro study demonstrated that abutment shade, ceramic thickness, and coping type affected the resulting shade of zirconia restorations.

시스틴으로 화학흡착된 금 코팅 니티놀 표면에 앙쪽성 이온 폴리에틸렌글리콜의 그래프트 및 특성 평가 (Grafting and Characterization of Zwitter Ionic Poly(ethylene glycol) on Gold-Coated Nitinol Surface Chemisorbed with L-Cysteine)

  • 신홍섭;박귀덕;김재진;김지흥;한동근
    • 폴리머
    • /
    • 제33권1호
    • /
    • pp.84-90
    • /
    • 2009
  • 니티놀(Nitinol) 합금(TiNi)은 혈관 스텐트로서 널리 사용되고 있다. 본 연구에서는 니티놀 합금의 혈액적 합성을 개선시키기 위해서 화학적인 표면개질을 행하였다. 먼저 니티놀의 표면을 금으로 코팅한 다음 시스턴(L-cysteine, C/N)을 화학흡착한 후 신규 합성한 양쪽성 이온 폴리에틸렌글리콜(PEG) (PEG-$N^+-SO_3{^-}$)을 그래프트 시켜서 TiNi-C/N-PEG-N-S를 제조하였다. 양쪽성 이온 PEG가 그래프트된 니티놀의 표면은 ATR-FTIR, ESCA 및 SEM을 통해서 확인하였고 친수성 표면은 물 접촉각의 감소를 통해서 입증하였다. 또한, 단백질 흡착 및 혈소판 점착과 혈액응고시간 측정과 같은 혈액적합성 평가 결과로부터 미처리 니티놀 합금에 비해서 표면개질된 니티놀 합금이 상대적으로 훨씬 우수한 혈액적합성을 나타내었다. 이는 그래프트된 친수성 PEG와 항응혈성 양쪽성 이온의 상승효과에 의해서 혈액적합성을 대폭 개선시킨 것으로 사료된다.

Correlation between microhardness and wear resistance of dental alloys against monolithic zirconia

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권3호
    • /
    • pp.127-135
    • /
    • 2021
  • Purpose. The aim of this study is to compare the hardness according to the conditions of metal alloys. Moreover, the correlation between the cast crown hardness before and after wear testing and the degree of wear for each dental alloy was assessed. Materials and Methods. Cast crowns of three metal alloys (Co-Cr, gold, and Ni-Cr alloys) opposing smooth-surface monolithic zirconia were used. The Vickers microhardness of the ingot (which did not undergo wear testing) and the cast crown before and after wear testing were measured for each alloy. Two-way ANOVA and Scheffé tests were used to compare the measured hardness values. Moreover, the Pearson correlation coefficient was used to evaluate the relationship between the surface hardness and the wear of the cast crown (α=.05). Results. There was no significant difference in the hardness before and after wear testing for the gold alloy (P>.05); however, the hardness of the worn surface of the cast crown increased compared to that of the cast crown before the wear tests of Ni-Cr and Co-Cr alloys (P<.05). Furthermore, there was no correlation between the wear and hardness of the cast crown before and after wear testing for all three metal alloys (P>.05). Conclusion. There was a significant difference in hardness between dental alloys under the same conditions. No correlation existed between the surface hardness of the cast crown before and after wear testing and the wear of the cast crown.

금합금계 매몰재의 Cristobalite와 Quartz 첨가량에 따른 열팽창과 압축강도 변화 (Effect of Cristobalite and Quartz on the Compression Strength and Thermal Expansion Coefficients of Gold Alloy Investment Materials)

  • 한만소
    • 공학논문집
    • /
    • 제6권2호
    • /
    • pp.141-151
    • /
    • 2004
  • 금합금계 매몰재 재료의 물리적 특성은 각각 열팽창계수과 압축강도, 입도 분포에 크게 좌우된다. 일반적으로 금합금계 매몰재는 cristobalite와 quartz, plaster로 주성분을 구성하고 있다. 그리고 cristobalite와 quartz의 열팽창계수는 $2.6\times10^{-6}/^\circC$, $2.32\times10^{-6}/^\circC$, 로 이 두 재료의 혼합비가 매몰재의 열팽창 계수를 변화시키는 매우 중요한 역할을 하고 있다. 현재 국내에서는 금합금계 매몰재는 전량 수입에 의존하고 있고 그 시장 수요 또한 대단히 크다. 따라서 균일한 입도 분포를 가지는 cristobalite와 quartz의 개발과 주조금속의 열팽창과 냉각에 따른 수축력을 고려한 열팽창계수를 가지면서 매몰재의 요구강도에 적합한 압축강도를 가지는 금합금계 매몰재의 개발이 필수적이다. 따라서 본 연구에서는 먼저 균일한 입도를 갖는 cristobalite와 quartz 분체의 제조와 cristobalite와 quartz의 혼합비에 따른 열팽창계수와 압축강도를 비교 분석하였다. 본 연구의 결과로 표면이 매끄럽고 균일한 입도 분포를 갖는 cristobalite와 quartz를 제조하였으며, cristobalite와 quartz의 혼합비가 45:25가 열팽창계수와 압축강도에서 매몰재가 요구하는 조건을 만족하였다.

  • PDF

아말감과 금합금의 Galvanic 전류 측정에 관한 실험적 연구 (A STUDY ON THE GALVANIC CURRENT BETWEEN GOLD AND AMALGAM)

  • 김영남;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.63-70
    • /
    • 1984
  • It was the purpose of this study to determine the galvanic current between a gold alloy inlay and four types of amalgam using the circuit through pulp chambers when the freshly extracted teeth with those restorations were brought into contact in a physiologic saline solution, and to investigate the effectiveness of cavity varnish or ammonated silver-nitrate on the surface of amalgam restoration in reducing galvanic current. The current was measured with current-to-voltage converter and recored on a physiograph 6630-257. The following results were obtained. 1. Generally, galvanic current decreased as the time elapsed. 2. Galvainc current decreased significantly in the first day and after then minimal change was observed until 30th day. 3. Initial galvanic current was 29.6 ${\mu}A$ in the cut amalgam and 24.5 ${\mu}A$ in Dispersalloy amalgam and after then the current was significantly decreased. 4. Initial galvanic current was 12.6 ${\mu}A$ in spherical amalgam (low copper amalgam) and 13.8 ${\mu}A$ in Tytin amalgam and the amount of change was lower in sperical amalgam and Tytin amalgam than that in lathe cut amalgam and Dispersalloy amalgam. 5. Painting ammoniated silver-nitrate or Copalite on the surface of amalgam resotration decreased initial galvanic current and ammoniated silver-nitrate is more effective in decreasing galvanic current than Copalite. 6. Galvanic current by contact between amalgam restoration and gold restoration increased abruptly and dropped rapidly becoming almost.

  • PDF