• Title/Summary/Keyword: glass behavior

Search Result 966, Processing Time 0.029 seconds

Nano/Micro Friction with the Contact Area (접촉 면적에 따른 나노/마이크로 마찰 특성)

  • Yoon Eui-Sung;Singh R. Arvind;Kong Hosung
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.209-215
    • /
    • 2005
  • Nano/micro friction with the contact area was studied on Si-wafer (100) and diamond-like carbon (DLC) film. Borosilicate balls of radii $0.32{\mu}m,\;0.5{\mu}m,\;1.25{\mu}m\;and\;2.5{\mu}m$ mounted on the top of AFM tip (NPS) were used for nano-scale contact and Soda Lime glass balls of radii 0.25mm, 0.5mm, 1mm were used for micro-scale contact. At nano-scale, the friction between ball and surface was measured with the applied normal load using an atomic force microscope (AFM), and at micro scale it was measured using ball-on flat type micro-tribotester. All the experiments were conducted at controlled conditions of temperature $(24\pm1^{\circ}C)$ and humidity $(45\pm5\%)$. Friction was measured as a function of applied normal load in the range of 0-160nN at nano scale and in the range of $1000{\mu}N,\; 1500{\mu}N,\;3000{\mu}N\;and\;4800{\mu}N$ at micro scale. Results showed that the friction at nano scale increased with the applied normal load and ball size for both kinds of samples. Similar behavior of friction with the applied normal load and ball size was observed for Si-wafer at micro scale. However, for DLC friction decreased with the ball size. This difference of in behavior of friction in DLC nano- and microscale was attribute to the difference in the operating mechanisms. The evidence of the operating mechanisms at micro-scale were observed using scanning electron microscope (SEM). At micro-scale, solid-solid adhesion was dominant in Silicon-wafer, while plowing in DLC. Contrary to the nano scale that shows almost a wear-less situation, wear was prominent at micro-scale. At nano- and micro-scale, effect of contact area on the friction was discussed with the different applied normal load and ball size.

Non-isothermal Crystallization Behaviors of Ethylene-Tetrafluoroethylene Copolymer (에틸렌-테트라플르오르에틸렌 공중합체의 비등온 결정화 거동)

  • Lee, Jaehun;Kim, Hyokap;Kan, Ho-Jong
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.803-809
    • /
    • 2012
  • The non-isothermal crystallization behavior of ethylene-tetrafluoroethylene (ETFE) copolymer was investigated by DSC and imaging FTIR analysis. Modified non-isothermal Avrami analysis was applied to interpret the crystallization behavior of ETFE. It was found that the less linearity in ln[-ln(1-X(t))] vs. ln(t) plot was obtained in thermal analysis comparison with imaging FTIR due to relatively small crystallization enthalpy change in ETFE. It means that imaging FTIR measured by overall IR absorption intensity change due to the crystallization was found to be effective to understand the non-isothermal crystallization kinetics of ETFE. In addition, the optical transmittance of ETFE was studied. The crystallite developed by slow cooling caused the light scattering and resulted in the increase of haze and the lowering of transmittance up to 8%. From our results, it was confirmed that cooling rate is an important processing parameter for maintaining optical transmittance of ETFE as a replacement material for glass.

Experimental Study of the Behavior Characteristics of Actuator Diaphragms in Thermopneumatic Micropumps (열공압형 마이크로펌프의 액추에이터 박막 거동 특성에 관한 실험적 연구)

  • Lee, Jong-Mun;Kim, Young-Deuk;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.599-606
    • /
    • 2010
  • In the present study, actuators with diaphragms of different thickness and chambers of different diameter are fabricated to examine experimentally how the behavior characteristics of the actuator diaphragm in a thermopneumatic micropump are affected by diaphragm thickness and chamber diameter under various operating conditions with different values of input voltage and frequency. The actuator comprises a microheater set on Pyrex glass, a chamber, and a diaphragm. For all values of the input energy, as the frequency decreases below 10 Hz, the maximum center deflection of the diaphragm greatly increases irrespective of diaphragm thickness and chamber diameter. At low frequencies, as the heat energy supplied to the chamber increases, the center of deflection of the diaphragm increases; the magnitude of deflection is high for thin diaphragms and for diaphragms whose chambers have small diameters. At frequencies higher than 10 Hz, all the design variables such as diaphragm thickness, chamber diameter, and the input energy have negligible effect on the center deflection of the diaphragm.

Effect of Potassium Oxide on the Early Hydration of Tricalciumaluminate (Tricalciumaluminate의 초기 수화반응에 미치는 $K_2O$의 영향)

  • Han, Ki-Sung;Choi, Man;Seo, Il-Young
    • Journal of the Korean Ceramic Society
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 1982
  • Two kinds of clinker liquid melts, one containing 2.0% of $K_2O$ and the other without $K_2O$, were prepared with the similar composition as those developed during the firing of portland cement clinker. One portion of melt was quenched and found to consist of glass together with traces of proto-$C_3A$, and the other portion was allowed to cool spontaneously to crystallize $C_3A$ and calciumferrite well. The product obtained by crystallization of the melt without $K_2O$showed cubic $C_3A$, while orthorhombic $C_3A$ was formed from the crystallized product containing $K_2O$. Studies on the hydration behavior of the samples made from the melts with 30% of gypsum were carried out for 24 hours by observation at regular intervals ettringite, monosulphate hydrates and gypsum which were formed or consumed during hydration. The samples without $K_2O$ in the melts were hydrated wth addition of proper amount of $K_2SO_4$ in the water for hydration. Hydration behavior of glassified $C_3A$ showed that it has low reactivity relative to crystallized $C_3A$, and also hydration reactivity of orthorhombic $C_3A$ was much lower than that of cubic $C_3A$ in 60 minutes. Potassium sulphate in the solution reduced the hydration reactivity of $C_3A$ . Evolution peaks of hydration heat examined by twin-type conduction micro-calorimeter showed that glassified $C_3A$ without $K_2O$ had secondary peak after 9 hours and $C_3A$ containing $K_2O$ after 12 hours. When crystallized $C_3A$ was hydrated, initial peaks of hydration heat were considerably high and there was no secondary peak for cubic $C_3A$ but the secondary peak of orthorhombic $C_3A$ appeared after 4 hours.

  • PDF

The Effect of Chemical Structure on the Adhesion Properties of Acrylic Pressure Sensitive Adhesives Prepared by Multifunctional Monomers (다관능성 단량체를 함유한 아크릴계 점착제의 화학적 구조에 따른 점착물성의 변화)

  • Cho, In-Mok;Kim, Ho-Gyum;Han, Dong-Hee;Lim, Jeong-Cheol;Min, Kyung-Eun
    • Polymer(Korea)
    • /
    • v.34 no.3
    • /
    • pp.226-236
    • /
    • 2010
  • UV irradiated acrylic pressure sensitive adhesives(PSAs) are prepared to be used for thermal pad in plasma display panel(PDP). The effect of the chemical structure of side-chain in comonomer and of crosslinking agent on wet-out property of acrylic PSAs in wide temperature range were investigated. The correlationship between viscoelastic behavior and adhesion properties, such as tack and peel strength, was also studied. The experimental results supported that wet-out and adhesion properties of acrylic PSAs were enhanced inversely proportional to side-chain length of comonomer in wide temperature range. The peel energy clearly increased in acrylic PSAs prepared by using di(ethylene glycol) dimethylacrylate (DEGDMA) for crosslinking agent. The results might be due to the difference in the glass transition temperature and viscoelastic behavior of acrylic PSAs.

Study on the Cable Wall System Applied to Reinforced Concrete Exterior (철근콘크리트구조 외장재에 케이블월 시스템 적용에 관한 연구)

  • Park, Hyun-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.579-585
    • /
    • 2017
  • Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.

Fragmentation Behavior Studies of Chalcones Employing Direct Analysis in Real Time (DART)

  • Motiur Rahman, A.F.M.;Attwa, Mohamed W.;Ahmad, Pervez;Baseeruddin, Mohammad;Kadi, Adnan A.
    • Mass Spectrometry Letters
    • /
    • v.4 no.2
    • /
    • pp.30-33
    • /
    • 2013
  • Chalcones are naturally occurring, biologically active molecules generating interest from a wide range of research applications including synthetic methodology development, biological activity investigation and studying fragmentation patterns. In this article, a series of chalcones has been synthesized and their fragmentation behavior was studied using modern ambient ionization technique Direct Analysis in Real Time (DART). DART ion source connected with an ion trap mass spectrometer was used for the fragmentation of various substituted chalcones. The chalcones were introduced to the DART source using a glass capillary without sample preparation step. All the chalcones showed prominent molecular ion peaks $[M]^{{\cdot}+}$ corresponding to the structures. Multistage mass spectral data $MS^n$ ($MS^2$ and $MS^3$) were collected for all the chalcones studied. The chalcones with substitutions at 3, 4 or 5 positions gave product ion peaks with the loss of a phenyl radical ($Ph^{\cdot}$) by radical initiated ${\alpha}$-cleavage, while substitution at 2 position of chalcone in the A-ring gave a product ion peak with the loss of substituted styryl radical (PhCH = $CH^{\cdot}$). In case of the chalcones with the substituent at 4 positions in A and B rings gave both types of fragmentation patterns. In conclusion, chalcones can be easily characterized using modern DART interface in very short time and efficiently without any cumbersome sample pretreatment.

Reaction Behavior of Ceramic Mat with Lithium Salt for the Electrolyte Separators of Thermal Batteries (전해질 분리판용 세라믹 부직포와 리튬염간의 반응성)

  • Cho, Kwang-Youn;Riu, Doh-Hyung;Shin, Dong-Geun;Lim, Kyoung-Hoon;Jin, Eun-Ju;Kim, Hyoun-Ee;Ha, Sang-Hyeon;Choi, Jong-Hwa
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.587-591
    • /
    • 2009
  • Lithium salt have been used mainly as electrolyte of thermal battery for electricity storage. Recently, The 3phase lithium salt(LiCl-LiF-LiBr) is tried to use as electrolyte of thermal battery for high electric power. It is reported that LiCl-LiF-LiBr salt have high ion mobility due to its high lithium ion concentration. Solid lithium salt is melt to liquid state at above $500{^{\circ}C}$. The lithium ion is easily reacted with support materials. Because the melted lithium ion has small ion size and high ion mobility. For the increasing mechanical strength of electrolyte pellet, the research was started to apply ceramic filter to support of electrolyte. In this study, authors used SiOC web and glass fiber filter as ceramic mat for support of electrolyte and impregnated LiCl-LiF-LiBr salt into ceramic mat at above $500{^{\circ}C}$. The fabricated electrolyte using ceramic mat was washed with distilled water for removing lithium salt on ceramic mat. The washed ceramic mat was observed for lithium ion reaction behavior with XRD, SEM-EDS and so on.

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement (유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구)

  • Um, Chan Hee;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1015-1024
    • /
    • 2015
  • An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

A Study on the Simulation Analysis of Nozzle Length and Inner Spiral Structure of a Waterjet (워터젯 노즐의 길이와 내부 나선 구조 유무에 따른 유체거동에 관한 전산해석)

  • Gwak, Cheong-Yeol;Shin, Bo-Sung;Go, Jeung-Sang;Kim, Moon-Jeong;Yoo, Chan-Ju;Yun, Dan-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.118-123
    • /
    • 2017
  • It is well known that water jetting is now widely used in the advanced cutting processes of polymers, metals, glass, ceramics, and composite materials because of some advantages, such as heatless and non-contacting cutting different from the laser beam machining. In this paper, we proposed the simulation model of waterjet by lengths and the inner spiral structure of the nozzle. The simulation results show that the outlet velocity of the nozzle is faster than the inlet. Furthermore, we found rapid velocity reduction after passing through the outlet. The nozzle of diameter ${\phi}500$ and length 70mm, shows the optimal fluid width and velocity distribution. Also, the nozzle with inner spiral structure shows a Gaussian distribution of velocity and this model is almost twice as fast as the model without spiral structure, within the effective standoff distance (2.5 mm). In the future, when inserting abrasive material into the waterjet, we plan to analyze the fluid flow and the particle behavior through a simulation model.