DOI QR코드

DOI QR Code

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement

유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구

  • 엄찬희 (가톨릭관동대학교 토목공학과) ;
  • 유승운 (가톨릭관동대학교 토목공학과)
  • Received : 2015.01.28
  • Accepted : 2015.08.11
  • Published : 2015.10.01

Abstract

An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

본 연구에서는 유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보를 대상으로 판 하부의 잔골재 부착여부, 웨브의 천공유무 및 간격, 상부플랜지 폭을 변수로 하여 휨 파괴실험을 수행하였다. GFRP 판 웨브를 천공하지 않은 경우 잔골재 부착효과 여부를 위한 실험 결과, 잔골재를 부착한 경우 미부착의 경우 보다 약 43% 높은 극한하중 값을 보여주었으며, 웨브의 천공유무 및 간격효과는 잔골재를 부착하지 않은 경우 천공간격이 3배인 경우가 약 23% 정도 높은 극한하중 값을 보여주었으며, 잔골재를 부착한 경우 천공 간격이 5배인 경우가 약 11% 정도 높은 극한하중 값을 보여주었다. 상부플랜지 영향을 살펴보면, 폭 20mm 경우가 40mm에 비해 약 12% 정도 큰 극한하중 값을 보여주었다.

Keywords

References

  1. Bank, L. C. (2006). Composites for construction: Structural design with FRP materials, John Wiely & Sons, NJ, USA.
  2. Bank, L. C., Oliva, M. G., Bae, H. U., Barker, J. and Yoo, S. W. (2006). "Test of pultruded FRP plank as formwork and rein­forcement for concrete structures." COMPOSITES 2006 Convention and Trade Show, American Composites Manufacturers Association, USA, October 18-20, pp. 1-8.
  3. Cheng, L., Zhao, L. M., Karbhari, V., Hegemier, G. A. and Seible, F. (2005). "Assessment of a steel-free fiber reinforced polymer-composite modular bridge system." Journal of Structural Engineering, Vol. 131, No. 3, pp. 498-506. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:3(498)
  4. Cho, J. R., Park, S. Y., Cho, K. H., Kim, S. T. and Kim, B. S. (2012). "Pull-out test and discrete spring model of fibre-reinforced polymer perfobond rib shear connector." Canadian Journal of Civil Engi­neering, Vol. 39, No. 12, pp. 1311-1320. https://doi.org/10.1139/cjce-2011-0573
  5. Cho, K. H., Park, S. Y., Cho, J. R. and Kim, B. S. (2007). "Structural systems and behavioral characteristics of an innovative FRP-concrete composite deck." Journal of Korean Society of Civil Engineers, KSCE, Vol. 27, No. 3, pp. 347-357 (in Korean).
  6. Erki, M. (1999). "Fiber-reinforced polymers for structural engineering in Canada." Structural Eng, International, Vol. 9, No. 4, pp. 278-280. https://doi.org/10.2749/101686699780481691
  7. Fukuyama, H., Matsuzaki, Y., Sato, Y., Iso, M. and Suwada, H. (2000). "Structural performance of engineered cementitious composite elements." Proceeding of 6th ASCCS Conference, pp. 969-976.
  8. Jeong, J. W., Park, K. T., Lee, Y. H. and Hwang, Y. K. (2007). "A comparison of the structural performance for GFRP bridge decks applied to vinyl ester and polyester resins." Journal of Korean Society of Civil Engineers, KSCE, Vol. 27, No. 4, pp. 479-484 (in Korean).
  9. Kim, Y. B. and Lee, J. H. (2005). "Simplified analytical model for flexural response of fiber reinforced plastic decks." Journal of the Korean Association for Shell and Spatial Structures, Vol. 5, No. 3, pp. 65-74 (in Korean).
  10. Tang, B. and Podolny, W. and Hooks, J. (1999). "A good start for fiber-reinforced polymer composite material bridges." American Society of Civil Engineers, Materials Engineering Congress, pp. 324-331.
  11. Yong, H. S., Hwang, Y. K., Kyung, K. S. and Park, Y. C. (2006). "A study of static behavior of FRP bridge deck concerning connection condition." Journal of Korean Society of Civil Engineers, KSCE, Vol. 26, No. 4, pp. 597-604 (in Korean).
  12. Yoo, S. W., Bae H. U., Oliva, M. and Bank, L. (2007). "Experimental study of concrete beam with FRP plank as formwork and rein-forcement." Journal of the Korea Concrete Institute, KCI, Vol. 19, No. 1, pp. 67-74 (in Korean). https://doi.org/10.4334/JKCI.2007.19.1.067
  13. Zureick, A. H., Shih, B. and Munley, E. (1995). "Fiber-reinforced polymeric bridge decks." Structural Engineering, SCI, Vol. 7, No. 3, pp. 257-266.