Study on the Cable Wall System Applied to Reinforced Concrete Exterior  

Park, Hyun-Sun (The College of Design, Shinhan University)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.18, no.3, 2017 , pp. 579-585 More about this Journal
Abstract
Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.
Keywords
Cable behavior; Cable wall system; Facade; High-rise buildings; Prestress;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Korea Super Tall Building Forum, "Super Tall Building Design and Teclmology", pp. 12-37, 2007.
2 Korean Association for Spatial Structures, "Design Code and Commentary for Cable Structures", pp. 93-109, 2009.
3 Gang SHI, Yongzhi ZUO, Xiaohao SHI, Yongjiu SHI, Yuanqing WANG, Zaoyang GUO, "Influence of Damages on Static Behavior of Single-layer Cable Net Supported Glass Curtain Wall: Full-scale Model Test, Research Article", pp. 382-395, 2010. DOl: http://doi.org/10.1007/s11709-010-0074-6   DOI
4 Gang SHI, "Influence of Damage on Static Behavior of Single-layer Cable Net Supported Glass Curtain Wall", Journal of Constructional Steel Research, pp. 54-78, 2010.
5 Ruo-qiang Feng, Ii-hong Ye, Yue Wu, Shi-zhao Shen, "Mechanical Behavior of Glass Panels Supported by Clamping Joints in Cable Net Facades", Journal of Steel Structures, pp. 213-305, 2012. DOI: http://doi.org/10.1007/s13296-012-1002-5   DOI
6 AAMA, "Maximum Allowable Deflection of Framing Systems for Building Cladding Components at Design Wind Loads", pp. 33-72, 1996.
7 MIDAS Information Technology Co. Ltd. "Analysis & Design" pp. 14-81 , 2014.
8 AAMA MCWM-1-89, "Metal Curtain Wall Manual", pp. 9-18, 2010.
9 Park, Sun-Woo, "Structural Glass-system in Roof and Facade", Korean Association for Spatial Structures, pp. 1-28, 2002.