• Title/Summary/Keyword: gf

Search Result 960, Processing Time 0.026 seconds

Development and Validation of the Simultaneous Analytical Method of Urinary Metals and Metalloids for the National Biomonitoring Programs (국가 바이오모니터링 프로그램을 위한 소변 중 금속류 동시분석법 개발 및 검증)

  • Cho, Yong Min;Yang, Minho;Im, Hosub;Cha, Sangwon;Lee, Jaeick;Kim, Ki Hun;Han, Sang Beom
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.594-604
    • /
    • 2019
  • Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

위성 영상과 해양 실측 자료를 활용한 부유사 농도 추정식 유도

  • Lee, Min-Seon;Park, Gyeong-Ae;Jeong, Jong-Ryul;Seo, Gang-Seon;An, Yu-Hwan;Mun, Jeong-Eon
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.136-136
    • /
    • 2010
  • 해색원격탐사에서 해수 type을 광학적 성질에 따라 Case-I water와 Case-II water로 구분한다. Case-I water는 기본적으로 조류 세포 및 그 쇄설물 그리고 미량의 용존 유기물을 포함하며, 맑은 해수인 대양이 이에 속한다. Case-II water는 부유 무기입자, 육상 기원입자 및 높은 용존 유기물 농도, 인간이 만든 유입물을 포함한 탁한 해수이며, 연안 해역의 해수가 이에 속한다(Gordon, 1983). Case-II water에 속하는 연안 해역의 부유사 농도는 해양 연안 환경 변화를 모니터링 할 수 있는 중요한 지표 중 하나이다. 부유사가 연안 환경, 연안 양식장, 어장 환경에 어떤 영향을 주는지 파악할 수 있다. 채수를 통하여 부유사 농도를 추정하는 것은 시간적 경제적 제약이 따른다. 하지만 위성자료와 실측 자료간의 상관관계가 잘 나타나는 계수를 유도하면, 실측없이 위성영상만 있으면 연속적인 부유사 농도 분포를 볼 수 있을 것으로 기대된다. 이런 목적으로 Landsat ETM+ 자료를 이용하여 광양만의 표층 부유사 농도를 추정하였다. 위성 통과시간에 맞춰 2009년 9월 22일과 11월 25일 2차례에 걸쳐 부유사 농도와 반사도를 광양만 16개 정점에서 측정하였다. 부유사 농도는 표층의 해수를 채수하여 GF/F 필터를 이용해 측정되었고, 반사도는 Spectroradiometer를 사용하여 350nm부터 1050nm까지 1nm 간격으로 측정되었다. Landsat ETM+ 자료와 실측 반사도는 원격반사도 $R_{rs}$로 변환되었고, 두 가지 $R_{rs}$를 실측 부유사 농도와 비교하여 부유사 농도 산출 계수를 유도하였다. 경험적으로 구한 계수를 사용하여 위성영상을 부유사 농도로 계산하였으며, 이는 같은 날의 실측 부유사 농도와 비슷한 공간분포를 나타내었다.

  • PDF

Grindability of Ti-10%Zr-X%Cr(X=0,1,3) Alloys for Dental Applications (치과용 Ti-10%Zr-X%Cr(X=0,1,3)합금의 연삭성)

  • Jung, Jong-Hyun;Shin, Jae-Woo
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.295-302
    • /
    • 2013
  • Purpose: The grindability of Ti-10%Zr-X%Cr(X=0,1,3) alloys in order to develop Ti alloys for dental applications with better machinability than unalloyed titanium has been evaluated. Methods: Experimental Ti-10%Zr-X%Cr(X=0,1,3) alloys were made in an argon-arc melting furnace. Slabs of experimental alloys were ground using a SiC abrasive wheel on an electric handpiece at one of the four rotational speeds of the wheel (12000, 18000, 25000 or 30000rpm) by applying a force(100gf). Grindability was evaluated by measuring the amount of metal volume removed per minute(grinding rate) and the volume ratio of metal removed compared to the wheel material lost, which was calculated from the diameter loss (grinding ratio). Experimental datas were compared the results with those of cp-Ti(commercially pure titanium) Results: It was observed that the grindability of Ti-10%Zr-X%Cr(X=0,1,3) alloys increased with an increase in the Cr concentration. More, they are higher than cp-Ti, particularly the Ti-10%Zr-3%Cr alloy exhibited the highest grindability at all rotational speeds except 12000rpm. There was significant difference in the grinding rate and grinding ratio between Ti-10%Zr-3%Cr alloy and cp-Ti at all rotational speeds(p<0.05). Conclusion: The Ti-10%Zr-3%Cr alloy exhibited better grindability at high rotational speeds, great potential for use as a dental machining alloy.

Plasma nitriding on chromium electrodeposit

  • Wang Liang;K.S. Nam;Kim, D.;Kim, M.;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.29-30
    • /
    • 2001
  • This paper presents some results of plasma nitriding on hard chromium deposit. The substrates were C45 steel and $30~50{\;}\mu\textrm{m}$ of chromium deposit by electroplating was formed. Plasma nitriding was carried out in a plasma nitriding system with $95NH_3{\;}+{\;}SCH_4$ atmosphere at the pressure about 600 Pa and different temperature from $450^{\circ}C{\;}to{\;}720^{\circ}C$ for various time. Optical microscopy and X-ray diffraction were used to evaluate the characteristics of surface nitride layer formed by nitrogen diffusion from plasma atmosphere inward iCr coating and interface carbide layer formed by carbon diffusion from substrate outward Cr coating. The microhardness was measured using microhareness tester at the load of 100 gf. Corrosion resistance was evaluated using the potentiodynamic measurement in 3.5% NaG solution. A saturated calomel electrode (SiCE) was used as the reference electrode. Fig.1 shows the typical microstructures of top surface and cross-section for nitrided and unnitrided samples. Aaer plasma nitriding a sandwich structure was formed consisting of surface nitride layer, center chromium layer and interface carbide layer. The thickness of nitride and carbide layers was increased with the increase of processing temperature and time. Hardness reached about 1000Hv after nitriding while 900Hv for unnitrided hard chromium deposit. X-ray diffraction indicated that surface nitrided layer was a mixture of $Cr_2N$ and CrN at low temperature and erN at high temperature (Fig.2). Anodic polarization curves showed that plasma nitriding can greatly improve the corrosion resistance of chromium e1ectrodeposit. After plasma nitriding, the corrosion potential moved to noble direction and passive current density was lower by 1 to 4 orders of magnitude compared with chromium deposit(Fig.3).

  • PDF

Multiple Signaling Molecules are Involved in Expression of CCL2 and IL-$1{\beta}$ in Response to FSL-1, a Toll-Like Receptor 6 Agonist, in Macrophages

  • Won, Keunsoo;Kim, Sun-Mi;Lee, Sae-A;Rhim, Byung-Yong;Eo, Seong-Kug;Kim, Koanhoi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.16 no.6
    • /
    • pp.447-453
    • /
    • 2012
  • TLR6 forms a heterodimer with TLR2 and TLR4. While proinflammatory roles of TLR2 and TLR4 are well documented, the role of TLR6 in inflammation is poorly understood. In order to understand mechanisms of action of TLR6 in inflammatory responses, we investigated the effects of FSL-1, the TLR6 ligand, on expression of chemokine CCL2 and cytokine IL-$1{\beta}$ and determined cellular factors involved in FSL-1-mediated expression of CCL2 and IL-$1{\beta}$ in mononuclear cells. Exposure of human monocytic leukemia THP-1 cells to FSL-1 resulted not only in enhanced secretion of CCL2 and IL-$1{\beta}$, but also profound induction of their gene transcripts. Expression of CCL2 was abrogated by treatment with OxPAPC, a TLR-2/4 inhibitor, while treatment with OxPAPC resulted in partially inhibited expression of IL-$1{\beta}$. Treatment with FSL-1 resulted in enhanced phosphorylation of Akt and mitogen-activated protein kinases and activation of protein kinase C. Treatment with pharmacological inhibitors, including SB202190, SP6001250, U0126, Akt inhibitor IV, LY294002, GF109203X, and RO318220 resulted in significantly attenuated FSL-1-mediated upregulation of CCL2 and IL-$1{\beta}$. Our results indicate that activation of TLR6 will trigger inflammatory responses by upregulating expression of CCL2 and IL-$1{\beta}$ via TLR-2/4, protein kinase C, PI3K-Akt, and mitogen-activated protein kinases.

Interfacial Microstructure and Mechanical Property of Au Stud Bump Joined by Flip Chip Bonding with Sn-3.5Ag Solder (Au 스터드 범프와 Sn-3.5Ag 솔더범프로 플립칩 본딩된 접합부의 미세조직 및 기계적 특성)

  • Lee, Young-Kyu;Ko, Yong-Ho;Yoo, Se-Hoon;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.29 no.6
    • /
    • pp.65-70
    • /
    • 2011
  • The effect of flip chip bonding parameters on formation of intermetallic compounds (IMCs) between Au stud bumps and Sn-3.5Ag solder was investigated. In this study, flip chip bonding temperature was performed at $260^{\circ}C$ and $300^{\circ}C$ with various bonding times of 5, 10, and 20 sec. AuSn, $AuSn_2$ and $AuSn_4$ IMCs were formed at the interface of joints and (Au, Cu)$_6Sn_5$ IMC was observed near Cu pad side in the joint. At bonding temperature of $260^{\circ}C$, $AuSn_4$ IMC was dominant in the joint compared to other Au-Sn IMCs as bonding time increased. At bonding temperature of $300^{\circ}C$, $AuSn_2$ IMC clusters, which were surrounded by $AuSn_4$ IMC, were observed in the solder joint due to fast diffusivity of Au to molten solder with increased bonding temperature. Bond strength of Au stud bump joined with Sn-3.5Ag solder was about 23 gf/bump and fracture mode of the joint was intergranular fracture between $AuSn_2$ and $AuSn_4$ IMCs regardless bonding conditions.

The effect of resin thickness on polymerization characteristics of silorane-based composite resin

  • Son, Sung-Ae;Roh, Hyoung-Mee;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.310-318
    • /
    • 2014
  • Objectives: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. Results: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.

A Design of Authentication/Security Processor IP for Wireless USB (무선 USB 인증/보안용 프로세서 IP 설계)

  • Yang, Hyun-Chang;Shin, Kyung-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2031-2038
    • /
    • 2008
  • A small-area and high-speed authentication/security processor (WUSB_Sec) IP is designed, which performs the 4-way handshake protocol for authentication between host and device, and data encryption/decryption of wireless USB system. The PRF-256 and PRF-64 are implemented by CCM (Counter mode with CBC-MAC) operation, and the CCM is designed with two AES (Advanced Encryption Standard) encryption coles working concurrently for parallel processing of CBC mode and CTR mode operations. The AES core that is an essential block of the WUSB_Sec processor is designed by applying composite field arithmetic on AF$(((2^2)^2)^2)$. Also, S-Box sharing between SubByte block and key scheduler block reduces the gate count by 10%. The designed WUSB_Sec processor has 25,000 gates and the estimated throughput rate is about 480Mbps at 120MHz clock frequency.

Effects of Coiling Temperature and Carbides Behavior on Stretch-flangeability for 980MPa Hot-rolled Steels (980 MPa급 열연강의 권취온도와 탄화물 거동에 따른 신장플랜지성)

  • Chun, Eun-Joon;Lee, Ju-Seung;Do, Hyeonghyeop;Kim, Seong-Ju;Choi, Yoon-Suk;Park, Yong-Ho;Kang, Namhyun
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.487-493
    • /
    • 2012
  • To analyze the factors on stretch-flangeability for 980 MPa-grade hot-rolled steels, two types of steels (Fe-Cr and Fe-Mo) were manufactured by hot-rolling. Manufactured steels at the low coiling temperature, such as 400 and $500^{\circ}C$, had poor stretch-flangeability due to un-uniformly distributed carbides and a large deviation of interphase hardness. However, when the coiling temperature was set at $650^{\circ}C$ with Fe-Cr steel, 998 MPa of ultimate tensile strength, 19% of total elongation and 65% of the hole expanding ratio were achieved by microstructural constituents of polygonal ferrite (PF) and granular ferrite (GF) dispersed with fine carbides (<50 nm). Therefore, the material to attain 980 MPa with superior formability was the Fe-Cr steel that was precipitation-hardened in polygonal ferrite and granular ferrite at the coiling temperature $650^{\circ}C$.

A Study on the Lifestyle of Korean Medical Students : Drinking Patterns and Eating Attitudes (한의대생의 생활양식 연구 - 음주양태와 섭식태도를 중심으로)

  • Go, Ho-Yeon;Lee, Jae-Hyok
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.21-29
    • /
    • 2018
  • Objectives : The purpose of this study was to examine the lifestyle of korean medicine students based on their drinking patterns and eating attitudes. Methods : The survey was conducted on 101 korean medicine students to investigate their psychological characteristics. They were asked to complete Self-Administered Alcoholism Screening Test, Eating Attitude Test, and Minnesota Multiphasic Personality Inventory-2. Results : A total of 101 Korean medical students participated in the study. Non-drinker 19, drinker were 82. Unlikely to, possible and potential alcoholism 79(78.2%), 17(16.8%) and 5(5%) respectively. The mean and standard deviation of SAAST in the subjects were $3.88{\pm}3.33$ and the EAT score was $8.09{\pm}8.693$. There was a significant difference in the MMPI-2 items between non-drinker and drinker. The SAAST had an effect on the EAT score(${\beta}=0.319$). Conclusions : As a result of MMPI-2 test, in the potential alcoholism group, scale D, Mf, Si, INTR, TPA, SOD, Mt and GF were shown higher, and AAS and GM were shown lower than the normal group. In the bad eating attitude group, scale Hy, RC4, DISC and AA were shown higher than the good eating attitude group.