• 제목/요약/키워드: gauge theory

검색결과 59건 처리시간 0.029초

AN EKELAND TYPE VARIATIONAL PRINCIPLE ON GAUGE SPACES WITH APPLICATIONS TO FIXED POINT THEORY, DROP THEORY AND COERCIVITY

  • Bae, Jong-Sook;Cho, Seong-Hoon;Kim, Jeong-Jin
    • 대한수학회보
    • /
    • 제48권5호
    • /
    • pp.1023-1032
    • /
    • 2011
  • In this paper, a new Ekeland type variational principle on gauge spaces is established. As applications, we give Caristi-Kirk type fixed point theorems on gauge spaces, and Dane$\check{s}$' drop theorem on seminormed spaces. Also, we show that the Palais-Smale condition implies coercivity on semi-normed spaces.

수압식 파고계 자료 분석에서 유속의 영향 (The Significance of Current-effect on Analysis of Wave Data Obtained from a Subsurface Pressure Gauge)

  • 이동영;오상호
    • Ocean and Polar Research
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2009
  • Subsurface pressure gauge has many advantages in measuring a wide range of wave spectra in coastal waters from wind waves to long waves. However, a shortcoming of the gauge is related to the difficulties in recovering surface wave spectra from subsurface pressure records. In this study, the effect of current on the pressure transfer function of the pressure gauge, and hence on the surface wave energy spectrum, was investigated by analyzing the subsurface pressure data based on the linear wave theory. For this purpose, laboratory experiments were carried out in a wave-current flume. Subsurface pressure records, as well as the surface elevation data, were obtained simultaneously under different wave and current conditions. Pressure transfer functions were obtained and compared with those estimated from the linear wave theory, both with and without inclusion of the current-effect. It was established that wave spectra obtained from subsurface pressure gauge were in closer agreement with those from surface wave gauge when current-effect on the pressure transfer function was taken into consideration for analysis.

RECENT DEVELOPMENTS IN DIFERENTIAL GEOMETRY AND MATHEMATICAL PHYSICS

  • Flaherty, F.J.
    • 대한수학회보
    • /
    • 제24권1호
    • /
    • pp.31-37
    • /
    • 1987
  • I want to focus on developments in the areas of general relativity and gauge theory. The topics to be considered are the singularity theorms of Hawking and Penrose, the positivity of mass, instantons on the four-dimensional sphere, and the string picture of quantum gravity. I should mention that I will not have time do discuss either classical mechanics or symplectic structures. This is especially unfortunate, because one of the roots of differential geometry is planted firmly in mechanics, Cf. [GS]. The French geometer Elie Cartan first formulated his invariant approach to geometry in a series of papers on affine connections and general relativity, Cf. [C]. Cartan was trying to recast the Newtonian theory of gravity in the same framework as Einstein's theory. From the historical perspective it is significant that Cartan found relativity a convenient framework for his ideas. As about the same time Hermann Weyl in troduced the idea of gauge theory into geometry for purposes much different than those for which it would ultimately prove successful, Cf. [W]. Weyl wanted to unify gravity with electromagnetism and though that a conformal structure would fulfill thel task but Einstein rebutted this approach.

  • PDF

SUS630 다이아프램을 이용한 반도체식 로드셀 (The Silicon Type Load Cell with SUS630 Diaphragm)

  • 문영순;이선길;류상혁;최시영
    • 센서학회지
    • /
    • 제20권3호
    • /
    • pp.213-218
    • /
    • 2011
  • The load cell is a force sensor and a transducer that is used to convert a physical force into a electrical signal for weighing equipment. Most conventional load cells are widely used a metal foil strain gauge for sensing element when force being applied spring element in order to converts the deformation to electrical signals. The sensitivity of a load cell is limited by its low gauge factor, hysteresis and creep. But silicon-based sensors perform with higher reliability. This paper presents the basic design and development of the silicon type load cell with an SUS630 diaphragm. The load cell consists of two parts the silicon strain gauge and the SUS630 structure with diaphragm. Structure analysis of load cell was researched by theory to optimize the load cell diaphragm design and to determine the position of peizoresistors on a silicon strain gauge. The piezo-resistors are integrated in the four points of silicon strain gauge processed by ion implantation. The thickness of the silicon strain gauge was polished by CMP under 100 ${\mu}M$. The 10 mm diameter SUS630 diaphragm was designed for loads up to 10 kg with 300 ${\mu}M$ of diaphragm thickness. The load cell was successfully tested, the variation of ${\Delta}$R(%) of four points on the silicon strain gauge is good linearity properties and sensitivity.

Ceramic 섬유의 강도 평가에 대한 Weibll 이론의 적용 (Application of Weifull강s Theory to Evaluation of Strength for Ceramic Fibers)

  • 이지환;김현수;한상훈
    • 한국세라믹학회지
    • /
    • 제27권8호
    • /
    • pp.1043-1049
    • /
    • 1990
  • In this work, strength of ceramic fibers and monofilament composites were evaluated on the basis of Weibull's theory. The fibers used were β-SiC and γ-Al2O3 monofilament composites was fabricated by coating Al on the fiber surface by the use of vacuum evaporation method. Average tensile strength of ceramic fibers showed the tendency to linearly decrease with increasing gauge length. Also, Weibull moduli of ceramic fibers were decreased with increasing gauge length, Weibull modulus of β-SiC was 3.5 for 6-50mm, 2.8 for 100-200mm. Weibull modulus of γ-Al2O3 was 6.5 for 20-50mm, 6 for 100mm. Fibers in monofilament retained their original as-produced strength to exposure temperature of 400℃. However, tensile strength of both monofilament composites approved to remarkably degrade due to interfacial reaction-induced flaws on the fiber surface after thermal exposure of 600℃. In this case, Weibull modulus of monofilament composites was 2.7 for β-SiC and 5.2 for γ-Al2O3 respectively.

  • PDF

엔트로피 이론을 이용한 수위관측망의 최적화 (Optimization of Stream Gauge Network Using the Entropy Theory)

  • 유철상;김인배
    • 한국수자원학회논문집
    • /
    • 제36권2호
    • /
    • pp.161-172
    • /
    • 2003
  • 본 연구에서는 주어진 수위관측망이 유역의 유출특성을 효과적으로 잡아낼 수 있느냐 하는 것에 초점을 맞추어 수위관측망을 평가하였다. 어떤 특수한 목적의 수위관측이나, 댐과 같은 구조물의 영향은 고려하지 알았으며, 단지 현존하는 수위관측소가 자연유량을 관측한다는 전제 하에 주어진 관측망의 최적화를 시도하였다. 본 연구는 남한강유역 내 총 31개의 수위관측소를 대상으로 수행하였으며, 수위관측망의 최적화에는 엔트로피의 개념을 이용하였다. 본 연구의 결과를 정리하면 다음과 같다. (1) 유역의 응답특성을 나타내는 대표단위도는 확률밀도함수로 변환하여 엔트로피의 개념에 효과적으로 적용할 수 있다. (2) 각 수위관측지점 대표단위도의 정확한 유도가 수위관측망의 평가 과정에서 가장 중요한 역할을 하였으며, 본 연구에서는 관측된 강우-유출 기록을 이용하여 유도한 단위도와의 비교를 통해 지형특성자료를 이용한 합성단위도의 이를 확인하였다. (3) 본 연구의 대상인 남한강 유역에는 대략 28개 이상의 수위관측소가 필요한 것으로 판단되며, 이 수는 단위도의 형상 및 유량의 크기를 모두 고려한 결과이다. 단위도의 형상만을 고려하는 경우에는 이보다 적은 23개의 수위관측소가 필요한 것으로 나타났다.

A multitype sensor placement method for the modal estimation of structure

  • Pei, Xue-Yang;Yi, Ting-Hua;Li, Hong-Nan
    • Smart Structures and Systems
    • /
    • 제21권4호
    • /
    • pp.407-420
    • /
    • 2018
  • In structural health monitoring, it is meaningful to comprehensively utilize accelerometers and strain gauges to obtain the modal information of a structure. In this paper, a modal estimation theory is proposed, in which the displacement modes of the locations without accelerometers can be estimated by the strain modes of selected strain gauge measurements. A two-stage sensor placement method, in which strain gauges are placed together with triaxial accelerometers to obtain more structural displacement mode information, is proposed. In stage one, the initial accelerometer locations are determined through the combined use of the modal assurance criterion and the redundancy information. Due to various practical factors, however, accelerometers cannot be placed at some of the initial accelerometer locations; the displacement mode information of these locations are still in need and the locations without accelerometers are defined as estimated locations. In stage two, the displacement modes of the estimated locations are estimated based on the strain modes of the strain gauge locations, and the quality of the estimation is seen as a criterion to guide the selection of the strain gauge locations. Instead of simply placing a strain gauge at the midpoint of each beam element, the influence of different candidate strain gauge positions on the estimation of displacement modes is also studied. Finally, the modal assurance criterion is utilized to evaluate the performance of the obtained multitype sensor placement. A bridge benchmark structure is used for a numerical investigation to demonstrate the effectiveness of the proposed multitype sensor placement method.

ANISOTROPY OF CMBR AND GAUGE INVARIANT COSMIC PERTURBATION THEORIES - SOME AMBIGUITIES AND PROBLEMS

  • XU CHONGMING;WU XUEJUN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.17-18
    • /
    • 1996
  • COBE's results on the anisotropy of the cosmic microwave background radiation (CMBR) is discussed. Some ambiguities in the linear GI cosmic perturbation theory are clarified. The problem of the last scattering surface and the deficiencies of the linear cosmic perturbation theory are mentioned. The possible ways to overcome the theoretical difficulties are discussed also.

  • PDF

Bourdon관을 이용한 전기식 압력변환기의 특성 (Characteristics of Electrical Type Pressure Transducer Which uses Bourdon Tube)

  • 김기중;백재규;한응교
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.14-22
    • /
    • 1983
  • The Bourdon tube pressure gauge is the most widely used primary detector for pressure in various kinds of fields recently. However in many cases lots of difficulties are encountered in telemetering, measuring the continuously changing pressure and recording as time goes by, etc. In this paper a Bourdon tube of flat-oval section is considered. On the basis of Wolf's theory, the very sensitive places are selected on the tube and full bridge arrangement is used. Then all of the characteristics are examined in order to use the pressure transducer practically into which the pressure gauge is converted. From the results, the error in meter reading is about $\pm$3% F.S., on the other hand, when measured with strain gauge, the error is within $\pm$1% F.S.. Also external acceleration on Bourdon tube hardly affect practical use.

  • PDF