• Title/Summary/Keyword: functional evaluation

Search Result 2,530, Processing Time 0.026 seconds

A Comparison of Wearing Evaluation Method for Bodice Pattern - Focusing on Obese Boys of School Year - (의복원형 설계의 착의 평가방법 비교 - 학령기 비만 남아를 중심으로 -)

  • Jo, Youn-Joo;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.4 no.4
    • /
    • pp.383-393
    • /
    • 2002
  • The purpose of this study was to evaluate wearing evaluation method in order to propose well fitted bodice pattern. For this study, the subjects were drawn from obese boys at the ages 9 to 11. Wearing evaluation had use of 3 bodice type and 3 evaluative method. The appearance evaluation was to evaluate subjects by professional group. The functional evaluation was to valued subjects by self-evaluation. The quantitative evaluation was to estimate subjects through Electomyograph. Wearing evaluation was done through questionnaire of 32 item in objectivity, 36 item in subjectivity, and 36 item in quantity. The data were analyzed by using ANOVA. From wearing evaluation, appearance and functional evaluation had significant most of them but quantitative evaluation had not significant. It was known that the human sense was more sensitive the quantitative mechanism. And its obtained by both functional evaluation and quantitative evaluation, respectively was found to be significantly correlated, Independent relation was observed in the results from both appearance evaluation and functional evaluation as well as from both functional evaluation and quantitative evaluation. Therefore, we propose that it is proper to evaluate the propriety of bodice pattern for obese boys of school year, mutually compromising both appearance evaluation and functional evaluation or both functional evaluation and quantitative evaluation.

Analysis of quercetin in extract of Hovenia dulcis Thunb (헛개나무과병추출물 중 퀘르세틴 분석)

  • Hu, SooJung;Oh, Jae-Myoung;Oh, Hyun-Suk;Moon, Myung-Hee;Bae, Yun-Young;Lee, Sung-Hye;Kim, Ji-An;Koo, Yong-Eui
    • Analytical Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.255-260
    • /
    • 2016
  • Based on the Korean Health Functional Food Act, health functional foods are dietary supplements containing nutrients or other substances that have nutritional or physiological effects. Since generic health functional food items have been expanded, this project was performed to develop a standardized analytical method of examining such sale items. The method exhibited high linearity in the quercetin calibration curve ($R^2$ > 0.999) over concentrations of $0-40{\mu}g/mL$. The limits of detection and quantitation for quercetin were $0.12{\mu}g/mL$ and $0.36{\mu}g/mL$, respectively, while quercetin recovery was 97.1-105.4 % with standard deviations of 1.15-3.11 %. To verify the accuracy of the analytical methods, the labeled amounts of purchased health functional foods were monitored. The recovery rate for multiple quercetin concentrations ranged from 82.5-105.1 % of the labeled amounts. Thus, the new method was suitable for all cases.

Algorithms for Causality Evaluation of Adverse Events from Health/Functional Foods (건강기능식품 부작용 원인분석을 위한 알고리즘)

  • Lee, Kyung-Jin;Park, Kyoung-Sik;Kim, Jeong-Hun;Lee, Young-Joo;Yoon, Tae-Hyung;No, Ki-Mi;Park, Mi-Sun;Leem, Dong-Gil;Yoon, Chang-Yong;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.302-307
    • /
    • 2011
  • One of the most important objectives of post-marketing monitoring of dietary supplements is the early detection of unknown and unexpected adverse events (AEs). Several causality algorithms, such as the Naranjo scale, the RUCAM scale, and the M & V scale are available for the estimation of the likelihood of causation between a product and an AE. Based on the existing algorithms, the Korea Food & Drug Administration has developed a new algorithm tool to reflect the characteristics of dietary supplements in the causality analysis. However, additional work will be required to confirm if the newly developed algorithm tool has reasonable sensitivity and not to generate an unacceptable number of false positives signals.

The Presentation of New Functional Evaluation Method (새로운 기능평가(機能評價) 방법(方法)의 제안(提案))

  • Kim, Gwang-Su
    • Journal of Korean Society for Quality Management
    • /
    • v.19 no.2
    • /
    • pp.108-116
    • /
    • 1991
  • Value Engineering has been recognized by many companies as a powerful and innovative techniques approach for cost down and improvement in function of product and service. Functional evaluation is the most important progress in VE activities. But it is often difficult to evaluate the function of a certain subject because the evaluation of function is very vague. This paper presents a new functional evaluation method using fuzzy theory. The purpose of this proposed method is the improvement in the precision of functional evaluation.

  • PDF

Development of a Multiplex Polymerase Chain Reaction Method for Simultaneous Detection of Genetically Modified Soy and Maize

  • Park, Kyoung-Sik;Kim, Mi-Gyeong;Leem, Dong-Gil;Yoon, Tae-Hyung;No, Ki-Mi;Hong, Jin;Kwon, Eun-Mi;Moon, Ae-Rie;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.278-280
    • /
    • 2010
  • This study was aimed to develop a novel qualitative multiplex polymerase chain reaction (PCR) for simultaneous detection of genetically modified (GM) soy and maize within a single reaction. The specific primers designed to detect four respective GM events (A2704-12, MON88017, Bt11, and MON863) were included in the tetraplex PCR system. Each of PCR products for four GM events could be distinguished by agarose gel based on their different lengths. The specificity and reproducibility of this multiplex PCR were evaluated. This multiplex PCR consistently amplified only a fragment corresponding to a specific inserted gene in each of the four GM events and also amplified all four of the PCR products in the simulated GM mixture. These results indicate that this multiplex PCR method could be an effective qualitative detection method for screening GM soy and maize in a single reaction.

Standardization for Analysis Method of Total Polyphenol in Complex of Picao Preto (피카오프레토 등 복합물 중 총 폴리페놀 분석법 표준화)

  • Hu, Soojung;Kim, Ji-An;Moon, Myung-Hee;Lee, Sung-Hye;Yoon, Hae-Seong;Hong, Jin-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.1
    • /
    • pp.44-49
    • /
    • 2018
  • As generic health functional food items have been expanded, this research project has been conducted to prepare a scientific and systematic standardized analytical method of relevant food item and examine the suitability of the method for health/functional foods on sale. Total polyphenol was necessary for development and verification of standardized analytical method. The method exhibited high linearity in the tannic acid calibration curve ($r^2$ > 0.999) over concentrations of $5-50{\mu}g/mL$. The limits of detection and quantitation for tannic acid were $5{\mu}g/mL$ and $15{\mu}g/mL$, respectively, while tannic acid recovery was 102.3-112.4% with standard deviations of 0.8-3.2%. To verify the accuracy of the analytical method, the labeled amounts of purchased health functional foods were monitored. The recovery for tannic acid was 105.6% of the labeled amounts. Thus, the new method was suitable for all cases.

A Study on the Evaluation for the Improvement of the Functional Movement of Women′s Wear -with Concentration on the Measurement of Functional Movement according to the Change of Cap Height- (여성복의 기능성 향상을 위한 착의 평가에 관한 연구 -소매산 높이 변화에 따른 기능성 측정을 중심으로-)

  • 박선경
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.2
    • /
    • pp.249-261
    • /
    • 2004
  • This research proves the ROM method (Range Of Motion), which has already been used in other countries, that measures the capacity of exercise and the adaptation of movement of functional garments for special purpose due to change of the height of basic sleeve sloper. Basically, the ultimate goal of the research is to improve the functional pattern design. Firstly, this research proves the proper application of ROM that is used for the evaluation of fitting test. Therefore, according to this research, the company is able to produce the sample that is appropriate to the various purpose for women garments and betters the evaluation of function of garments. Moreover, it suggests that the evaluation of fitting test satisfies the consumers who desire to try better garments and contributes to the competitions among the companies that bring more improvements to the fashion design.

  • PDF

Evaluation of the Functional Cosmetics

  • Yun, Mi-Ok
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2007.11a
    • /
    • pp.117-126
    • /
    • 2007
  • Cosmetics have mild activity on the human body, and intended to be used for cleaning, beautifying the human body, and also keeping healthy skin or hair, promoting attractiveness or altering the appearance. Functional cosmetics, in other words cosmeceuticals, are restricted for following functions: 1) Whiten the skin tone by preventing deposition of melanin pigmentation or lightening of the color of melanin of skin, 2) alleviate or improve wrinkles of the skin, and 3) protect the skin from the ultra violet rays from the sun. According to the functions of the functional cosmetics, skin whitening products, anti-wrinkle products, and suntan & sunscreen products are manufactured. In order to manufacture and import the functional cosmetics in Korea, the approval process in KFDA is necessary. The review process in KFDA is performed based on The Korea Food and Drug Administration Notification 2007-44, "The Regulation of Reviewing the Functional Cosmetics" (June 29, 2007). Only after the approval of KFDA, functional cosmetics are allowed to advertise to the consumers for their functionality.

  • PDF

Relationship Between a New Functional Evaluation Model and the Fugle-Meyer Assessment Scale for Evaluating the Upper Extremities of Stroke Patients

  • Kim, Jung-Hyun;Kim, Hyun-Jin;Lee, Seung-Gu;Song, Chang-Ho
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.305-313
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the relationship between a functional evaluation model and the Fugl-Meyer assessment (FMA) scale in evaluating the upper extremities of stroke patients Methods: Thirty-eight stroke patients were evaluated using the FMA and performed reaching and grasping motions using a three-dimensional motion analysis (Qquas 1 series, Qualisys AB, Sweden). The participants sat on a chair with a backrest. The position of the cup was located at a distance of 80% to the front arm length. The markers were attached to the sternum, acromion, elbow lateral epicondyle, ulnar styloid process, three metacarpal heads, and the distal phalanges of the thumb and index finger. The variables of the correlation between the functional evaluation model and the FMA scale were analyzed. Multiple regression (stepwise) was used to investigate the effect of the kinematic variables. Results: A significant negative correlation was found between the movement time (p < 0.05), movement unit (p < 0.05), and trunk displacement values (p < 0.05) in the FMA total scores, while a positive correlation was found between the peak velocity (p < 0.05) and maximum grip aperture values (p < 0.05). As a result of the multiple regression analysis, the most significant factor was the movement unit, followed by the general movement assessment and trunk displacement. The explained FMA total score value was 62%. Conclusion: This study presents a new functional evaluation model for assessing the reaching and grasping ability of stroke patients. The factors of the proposed functional evaluation model showed significant correlations with the FMA scale scores and confirmed that the new functional evaluation model explained the FMA by 67%. This suggests a new functional evaluation model for reaching and grasping stroke patients.