• 제목/요약/키워드: frequency resonance test

검색결과 341건 처리시간 0.029초

Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits

  • Kim, Jong-Ryoul;Kim, Sung-Hee;Kim, In-Ryoung;Park, Bong-Soo;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권1호
    • /
    • pp.2-8
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone. Materials and Methods: Thirteen New Zealand white male rabbits weighing $3.0{\pm}0.5kg$ were used for this study. Dental titanium implants (3.75 mm in diameter and 8.5 mm in length, US II RBM plus fixture; Osstem, Seoul, Korea) were implanted into both femurs of each rabbit. The rabbits were randomly divided into a LLLT group and a control group. The LLLT was initiated immediately after surgery and then repeated daily for 7 consecutive days in the LLLT group. Six weeks and 12 weeks after implantation, we evaluated and compared the osseointegration of the LLLT group and control group, using histomorphometric analysis, removal torque testing, and resonance frequency analysis (RFA). The results were statistically significant when the level of probability was 0.05 or less based on a non-parametric Mann-Whitney U-test. Results: The implant survival rate was about 96%. Histologically and histomorphometrically, we observed that the titanium implants were more strongly attached in LLLT group than in control group. However, there was no significant difference between the LLLT group and control group in removal torque or RFA. Conclusion: Histologically, LLLT might promote cell-level osseointegration of titanium implants, but there was no statistically significant effects.

A comparison of the implant stability among various implant systems: clinical study

  • Kim, Jae-Min;Kim, Sun-Jong;Han, In-Ho;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.31-36
    • /
    • 2009
  • PURPOSE. To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period(24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems(group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ(implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values(group A=0.0022, C=0.017, R=0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position(P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months(plateau effect).

The evaluation of implant stability measured by resonance frequency analysis in different bone types

  • Sargolzaie, Naser;Samizade, Sarah;Arab, Hamidreza;Ghanbari, Habibollah;Khodadadifard, Leila;Khajavi, Amin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권1호
    • /
    • pp.29-33
    • /
    • 2019
  • Objectives: Bone density seems to be an important factor affecting implant stability. The relationship between bone density and primary and secondary stability remains under debate. The aim of this study was to compare primary and secondary stability measured by resonance frequency analysis (RFA) between different bone types and to compare implant stability at different time points during 3 months of follow-up. Materials and Methods: Our study included 65 implants (BioHorizons Implant Systems) with 3.8 or 4.6 mm diameter and 9 or 10.5 mm length in 59 patients. Bone quality was assessed by Lekholm-Zarb classification. After implant insertion, stability was measured by an Osstell device using RFA at three follow-up visits (immediately, 1 month, and 3 months after implant insertion). ANOVA test was used to compare primary and secondary stability between different bone types and between the three time points for each density type. Results: There were 9 patients in type I, 18 patients in type II, 20 patients in type III, and 12 patients in type IV. Three implants failed, 1 in type I and 2 in type IV. Stability values decreased in the first month but increased during the following two months in all bone types. Statistical analysis showed no significant difference between RFA values of different bone types at each follow-up or between stability values of each bone type at different time points. Conclusion: According to our results, implant stability was not affected by bone density. It is difficult to reach a certain conclusion about the effect of bone density on implant stability as stability is affected by numerous factors.

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

DNA Dynamics: a Fluorescence Resonance Energy Transfer Study Using a Long-Lifetime Metal-Ligand Complex

  • Kang, Jung-Sook;Lakowicz, Joseph-R.;Piszczek, Grzegorz
    • Archives of Pharmacal Research
    • /
    • 제25권2호
    • /
    • pp.143-150
    • /
    • 2002
  • Fluorescent probes bound to DNA typically display nanosecond decay times and reveal only nanosecond motions. We extend the time range of measurable DNA dynamics using $[Ru(pby)_2(dppz)]^{2+}$ (bpy=2.2'-bipyridine, dppz=dipyrido[3,2-a2',3'-c]phenazine) (RuBD) which displays a mean lifetime near 90 ns. To test the usefulness of RuBD as a probe for diffusive processes in calf thymus DNA, we compared the efficiencies of fluorescence resonance energy transfer (FRET) using three donors which display lifetimes near 5 ns for acridine orange (AO), 22 ns for ethidum bromide (EB) and 92 ns for RuBD, with nile blue (NB) as the acceptor. The F rster distances for AO-NB, EB-NB and RuBD-NB donor-acceptor pairs were 42.3, 52.3, and $30.6{\;}{\AA}$, respectively. All three donors showed dramatic decreases in fluorescence intensities and more rapid intensity decays with increasing NB concentrations. The intensity decays of AO and EB in the presence of varying concentrations of NB were satisfactorily described by the one-dimensional FRET model without diffusion (Blumen and Manz, 1979). In the case of the long-lifetime donor RuBD, the experimental phase and modulation somewhat deviated from the recovered values computed from this model. The recovered NB concentrations and FRET efficiencies from the model were slightly larger than the expected values, however, the recovered and expected values did not show a significant difference. Thus, it is suggested that the lifetime of RuBD is too short to measure diffusive processes in calf thymus DNA.

Safety of Stress Cardiac Magnetic Resonance in Patients With Moderate to Severe Aortic Valve Stenosis

  • Janek Salatzki;Andreas Ochs;Nadja Kirchgassner;Jannick Heins;Sebastian Seitz;Hauke Hund;Derliz Mereles;Matthias G. Friedrich;Hugo A. Katus;Norbert Frey;Florian Andre;Marco M. Ochs
    • Journal of Cardiovascular Imaging
    • /
    • 제31권1호
    • /
    • pp.26-38
    • /
    • 2023
  • BACKGROUND: Dobutamine and adenosine stress cardiac magnetic resonance (CMR) imaging is relatively contraindicated in patients with moderate to severe aortic valve stenosis (AS). We aimed to determine the safety of dobutamine and adenosine stress CMR in patients with moderate to severe AS. METHODS: In this retrospective study patients with AS who underwent either dobutamine or adenosine stress CMR for exclusion of obstructive coronary artery disease were enrolled. We recorded clinical data, CMR and echocardiography findings, and complications as well as minor symptoms. Patients with AS were compared to matched individuals without AS. RESULTS: A total of 187 patients with AS were identified and compared to age-, gender- and body mass index-matched 187 patients without AS. No severe complications were reported in the study nor the control group. The reported frequency of non-severe complications and minor symptoms were similar between the study and the control groups. Nineteen patients with AS experienced non-severe complications or minor symptoms during dobutamine stress CMR compared to eighteen patients without AS (p = 0.855). One patient with AS and two patients without AS undergoing adenosine stress CMR experienced minor symptoms (p = 0.562). Four examinations were aborted because of chest pain, paroxysmal atrial fibrillation and third-degree atrioventricular block. Inducible ischaemia, prior coronary artery bypass grafting, prior stroke and age were associated with a higher incidence of complications and minor symptoms. CONCLUSIONS: Moderate to severe AS was not associated with complications during CMR stress test. The incidence of non-severe complications and minor symptoms was greater with dobutamine.

차륜형장갑차용 유압펌프의 해석 및 시험을 통한 신뢰성 확보에 관한 연구 (A Study on Ensuring Reliability of Hydraulic Pumps for Wheeled Armored Vehicles through Analysis and Testing)

  • 김원재;이호준;최청석;서석호;최성웅
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.78-84
    • /
    • 2020
  • This paper introduces the structural and vibration analysis performed in the localization development process of hydraulic pumps used in wheeled armored vehicles. The maximum strain, maximum stress, maximum displacement, and minimum safety factor were calculated using structural analysis. Furthermore, it was found that the dangerous resonance frequency was avoided through vibration analysis. In addition, the reliability of the analysis results was verified by passing various tests, such as the actual vibration test and the actual durability test. The developed hydraulic pump is expected to contribute significantly to the maintenance of military vehicles in the future.

Development of a Ultrasonic System for Nano-Surface Reformation Process

  • Kim, Hyunse;Lim, Euisu;Park, Jong-Kweon
    • 한국생산제조학회지
    • /
    • 제26권4호
    • /
    • pp.365-370
    • /
    • 2017
  • In this article, a 20 kHz Titanium (Ti) ultrasonic waveguide system for a nano-surface reformation process was designed and fabricated. First, finite element analysis using ANSYS software was performed to find the optimal dimensions. The obtained anti-resonance frequency for the Ti transducer with the piezoelectric device was 20.0 kHz, which value agreed well with the experiment result of 20.1 kHz (0.5% error). To test the system, chromium molybdenum steel (SCM) 435 was chosen as a test-piece. The result proved that the reformed depth was $36{\mu}m$. In addition, hardness was measured before and after the process. The value was changed from 14 HRC to 21 HRC, which is 50% increasing rate. Finally, the friction coefficient test result showed that the surface coefficient was reduced from 0.14 to 0.10 (28.6% reduction). Based on the results, the Ti ultrasonic equipment is regarded as a useful device for nano-scale surface reformation.

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권3호
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

연료전지차용 수소배출 배관 및 배관이음매 안전성 평가를 위한 기초 연구 (The Basic Study on the Leak Test Method of the Hydrogen Exhaust Pipe for a Fuel Cell Vehicle)

  • 서호철;박경석;서경두;용기중
    • 한국정밀공학회지
    • /
    • 제28권2호
    • /
    • pp.185-192
    • /
    • 2011
  • This study deals with a basic proposal to prove the safety for the exhausted fittings of the hydrogen fuel cell vehicle. First, this study was approached to numerical analysis solving to close the exact boundary condition (Axial, Bending, Lateral) and the second, this study produced the Lateral movement equipment for the vibration. For the numerical analysis, This study was considered with the exact solution of Lateral movement and the resonance effect for durability sample according to fitting positions. The second, This study was made for special equipment for displacement/gas leak and the frequency because the domestic samples were comparing with foreign fitting and foreign fitting for the hydrogen fuel cell vehicle. The result of this study was satisfied with domestic fittings for the basic reference but it need more test because of other situation for hydrogen fuel cell vehicle.