Performance test of 100 W linear compressor

  • Ko, J. (Korea Institute of Machinery & Materials) ;
  • Koh, D.Y. (Korea Institute of Machinery & Materials) ;
  • Park, S.J. (Korea Institute of Machinery & Materials) ;
  • Kim, H.B. (Korea Institute of Machinery & Materials) ;
  • Hong, Y.J. (Korea Institute of Machinery & Materials) ;
  • Yeom, H.K. (Korea Institute of Machinery & Materials)
  • Received : 2013.08.21
  • Accepted : 2013.09.13
  • Published : 2013.09.30

Abstract

In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

Keywords

References

  1. M. K. Heun, S. A. Collins, D. L. Johnson, R. G. Ross, Jr., "Investigation of gas effects on cryocooler resonance characteristics", Cryocooler 9, pp. 421-430, 1997.
  2. G. S. Choi and K. J. Kim, "Analysis of nonlinear dynamics in a linear compressor", JSME Int. J. C-Mech. Sy., vol. 43, pp. 545-552, 2000. https://doi.org/10.1299/jsmec.43.545
  3. J. Ko, H. Kim, S. J. Park, Y. J. Hong, H. Yeom, D. Y. Koh, "Analysis of electric circuit using capacitor for driving linear compressor", Progress in Superconductivity and Cryogenics, vol. 14, pp. 43-47, 2012. https://doi.org/10.9714/sac.2012.14.3.043
  4. H. Zou, L. Zhang, G. Peng, "Efficiency measurement of linear oscillation motor with gas load", Int. J. Appl. Electrom., vol. 34, pp. 109-118, 2010.
  5. Y. J. Hong, S. J. Park, H. B. Kim, H. K. Yeom, "The numerical analysis of performance of the Stirling cryocooler", Superconducting and cryogenics, vol. 4, pp. 58-62, 2002